Cross-sectional diagnostic accuracy study of self-testing for proteinuria during hypertensive pregnancies: The UDIP study

被引:6
|
作者
Jakubowski, Bethany Ellen [1 ]
Stevens, Richard [1 ]
Wilson, Hannah [2 ]
Lavallee, Layla [1 ]
Brittain, Lesley [3 ]
Crawford, Carole [1 ]
Hodgkinson, James [4 ]
Hinton, Lisa [5 ]
Mackillop, Lucy [6 ]
Chappell, Lucy C. [2 ]
McManus, Richard J. [1 ]
Tucker, Katherine Louise [1 ]
机构
[1] Univ Oxford, Nuffield Dept Primary Care Hlth Sci, Oxford OX2 6GG, England
[2] Kings Coll London, Dept Women & Childrens Hlth, London, England
[3] NHS Fdn Trust, Birmingham Women & Childrens Hosp, Oxford, England
[4] Univ Birmingham, Coll Med & Dent Sci, Murray Learning Ctr, Inst Appl Hlth Res, Birmingham, W Midlands, England
[5] Univ Cambridge, THIS Inst, Clifford Allbutt Bldg, Cambridge Biomed Campus, Cambridge, England
[6] Univ Oxford, Nuffield Dept Womens & Reprod Hlth, Oxford, England
关键词
diagnostic accuracy study; hypertension; pre-eclampsia; pregnancy; proteinuria; self-testing; CREATININE RATIO; MANAGEMENT; WOMEN;
D O I
10.1111/1471-0528.17180
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective To determine the accuracy of self-testing for proteinuria during pregnancy. Design Diagnostic accuracy study. Setting Antenatal clinics, maternity assessment units and inpatient wards at three hospital sites. Population or Sample 345 pregnant women. Methods Pregnant women self-tested in-clinic for urinary protein using visually read dipsticks with samples then sent for laboratory estimation of the spot protein-creatinine ratio (PCR) (primary reference test). Secondary index tests included testing by antenatal healthcare professionals and an automated colorimetric reader. Main outcome measures Sensitivity, specificity, negative predictive value, positive predictive value and likelihood ratios were calculated for self-testing (primary index test) along with healthcare professional and colorimetric testing compared to the primary reference test (PCR). Results 335/345 (97%) had sufficient data to be included in the analysis. Self-testing had a sensitivity of 0.71 (95% confidence interval [CI] 0.62-0.79) and a specificity of 0.89 (95% CI 0.84-0.92) compared to PCR. Sensitivity and specificity of testing by healthcare professionals and the colorimetric reader were similar: sensitivity 0.73 (95% CI 0.64-0.80) and 0.78 (95% CI 0.69-0.85), respectively; specificity 0.88 (95% CI 0.82-0.92) and 0.83 (95% CI 0.78-0.88), respectively. Conclusion Pregnant women can visually read a dipstick for urinary protein with similar accuracy to antenatal healthcare professionals. Automated colorimetric testing was not significantly different, in contrast to some previous studies. Self-testing has the potential to form part of a self-monitoring regime in pregnancy.
引用
收藏
页码:2142 / 2148
页数:7
相关论文
共 50 条
  • [31] Treatment of 5413 hypertensive patients: a cross-sectional study
    Paulsen, M. S.
    Sondergaard, J.
    Reuther, L.
    Larsen, P. S.
    Munck, A. P.
    Larsen, P. V.
    Damsgaard, J.
    Poulsen, L.
    Hansen, D. G.
    Jacobsen, I. A.
    Larsen, M. L.
    Christensen, H. R.
    Christensen, B.
    Andersen, M.
    FAMILY PRACTICE, 2011, 28 (06) : 599 - 607
  • [32] Treatment adherence in hypertensive patients - a cross-sectional study
    Amaral, Odete
    Chaves, Claudia
    Duarte, Joao
    Coutinho, Emilia
    Nelas, Paula
    Preto, Olinda
    5TH ICEEPSY INTERNATIONAL CONFERENCE ON EDUCATION & EDUCATIONAL PSYCHOLOGY, 2015, 171 : 1288 - 1295
  • [33] Accuracy of lung auscultation to detect abnormal respiratory mechanics: A cross-sectional diagnostic study
    Xavier, Glaciele
    Melo, Cesar
    Gaio, Eduardo
    Amado, Veronica
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [34] Diagnostic Accuracy of Various Radiological Measurements in the Evaluation and Differentiation of Flatfoot: A Cross-Sectional Study
    Khan, Fayaz
    Chevidikunnan, Mohamed Faisal
    Alsobhi, Mashael Ghazi
    Ahmed, Israa Anees Ibrahim
    Al-Lehidan, Nada Saleh
    Rehan, Mohd
    Alalawi, Hashim Abdullah
    Abduljabbar, Ahmed H.
    DIAGNOSTICS, 2022, 12 (10)
  • [35] Accuracy of pulmonary auscultation to detect abnormal respiratory mechanics: A cross-sectional diagnostic study
    Xavier, Glaciele Nascimento
    Magalhaes Duarte, Antonio Carlos
    Melo-Silva, Cesar Augusto
    Ventura Gaio dos Santos, Carlos Eduardo
    Amado, Veronica Moreira
    MEDICAL HYPOTHESES, 2014, 83 (06) : 733 - 734
  • [36] Diagnostic Accuracy of Current Glossoptosis Classification Systems: A Nested Cohort Cross-Sectional Study
    Manica, Denise
    Schweiger, Claudia
    Sekine, Leo
    Fagondes, Simone Chaves
    Kuhl, Gabriel
    Collares, Marcus Vinicius
    Cauduro Marostica, Paulo Jose
    LARYNGOSCOPE, 2018, 128 (02): : 502 - 508
  • [37] Prevalence and diagnostic accuracy of microcephaly in a pediatric cohort in Brazil: a retrospective cross-sectional study
    Antunes Pascalicchio Bertozzi, Ana Paula
    Gazeta, Rosa Estela
    Gillo Fajardo, Thamirys Cosmo
    Moron, Antonio Fernandes
    Soriano-Arandes, Antoni
    Alarcon, Ana
    Garcia-Alix, Alfredo
    da Silva, Alify Bertoldo
    Florence Filho, Nemesio
    Pereira Sarmento, Stephanno Gomes
    Witkin, Steven S.
    Duarte Passos, Saulo
    JORNAL DE PEDIATRIA, 2021, 97 (04) : 433 - 439
  • [38] Spontaneous pregnancies and determinant factors in infertility: A cross-sectional study
    Saadati, Nasrin
    Nikbakht, Roshan
    Sattari, Alireza
    Amininezhad, Fatemeh Sadat
    INTERNATIONAL JOURNAL OF REPRODUCTIVE BIOMEDICINE, 2020, 18 (10) : 905 - 910
  • [39] Repeat adolescent pregnancies in Southwestern Uganda: A cross-sectional study
    Ramachandran, Rupa
    Namatovu, Shakillah
    Atwine, Daniel
    Tumuhairwe, Jackline
    Nyakato, Viola Nilah
    Kemigisha, Elizabeth
    Ivanova, Olena
    WOMENS HEALTH, 2024, 20
  • [40] Accuracy of Fetal Transcerebellar Diameter in Predicting Gestational Age in Singleton Pregnancies During the Second Trimester: A Cross-Sectional Study in Sudan
    Elhag, Amal
    Alobaidy, Mohammad
    Adam, Dalia
    Abdalla, Eltayeb
    Hassan, Mahasin G.
    Elmahdi, Tasneem S. A.
    Elnaeem, Mozdalifah
    Mohammed, Safaa
    JOURNAL OF CLINICAL ULTRASOUND, 2025,