Development of radiation monitors for measurement of synchrotron radiation

被引:0
|
作者
Singh, Sunil K. [1 ]
Mahant, A. K. [1 ]
Sahu, Abinash [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiat Safety Syst Div, Bombay 110085, Maharashtra, India
关键词
Synchrotron radiation; INDUS-II; Radiation monitor;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
High intensity and predominantly low energy Synchrotron Radiation (SR) are produced at INDUS-II Synchrotron Radiation Source at Raja Ramanna Centre for Advanced Technology (RRCAT). SR monitoring instruments were developed to measure and monitor SR radiations. Salient features of these monitors include high sensitivity, isotropic response, audio alarm indicating radiation levels above 1 mR/h and outputs for controlling the door interlocks. Paper describes the design criteria and results of measurements.
引用
收藏
页码:797 / 798
页数:2
相关论文
共 50 条
  • [21] A comparative radiation study at ALBA synchrotron facility between Monte Carlo modeling and radiation monitors dosimetry measurements
    Devienne, A.
    Aymerich, N.
    Garcia-Fuste, M. J.
    Queralt, X.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 365 - 367
  • [22] Radiation monitors. Laundry monitors
    Nuclear Engineering International, 1992,
  • [23] Visible-light beam size monitors using synchrotron radiation at CESR
    Wang, S. T.
    Rubin, D. L.
    Conway, J.
    Palmer, M.
    Hartill, D.
    Campbell, R.
    Holtzapple, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 703 : 80 - 90
  • [24] SYNCHROTRON RADIATION AND RADIATION BIOLOGY
    ITO, T
    JOURNAL OF RADIATION RESEARCH, 1988, 29 (01) : 9 - 9
  • [25] SYNCHROTRON RADIATION WITH RADIATION REACTION
    NELSON, RW
    WASSERMAN, I
    ASTROPHYSICAL JOURNAL, 1991, 371 (01): : 265 - 276
  • [26] Radiation voice monitors
    Suzuki, N
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D247 - D249
  • [27] Dither monitors radiation
    Spray, P
    EDN, 1997, 42 (18) : 53 - 53
  • [28] Testing of environmental radiation monitors using the Riso low-level radiation measurement stations
    Botter-Jensen, L
    RADIATION PROTECTION DOSIMETRY, 2000, 92 (1-3) : 109 - 114
  • [29] Serendipitous radiation monitors
    Fleischer, RL
    AMERICAN SCIENTIST, 2002, 90 (04) : 324 - 331
  • [30] Influence of extraterrestrial radiation on radiation portal monitors
    Pacific Northwest National Laboratory, Richland, WA 99352, United States
    IEEE Trans Nucl Sci, 3 (1575-1583):