A method for differentiating ocular higher-order aberrations and light scatter as applied to retinitis pigmentosa

被引:4
|
作者
Shahidi, M [1 ]
Yang, YR [1 ]
Rajagopalan, AS [1 ]
Alexander, KR [1 ]
Zelkha, R [1 ]
Fishman, GA [1 ]
机构
[1] Univ Illinois, Dept Ophthalmol & Visual Sci, Chicago, IL 60612 USA
关键词
retinal image; ocular aberrations; light scatter; retinitis pigmentosa;
D O I
10.1097/01.opx.0000187842.27258.c9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study is to report a method for differentiating ocular higher-order aberrations and intraocular light scatter based on a deconvolution technique. Methods. An optical system was used to image a laser slit on the retina and also to perform Shack-Hartmann wavefront sensing. From the laser slit image, the line spread function, incorporating both ocular higher-order aberrations and light scatter, was derived. The laser slit image was deconvolved with a point spread function obtained from the Shack-Hartmann image. The area under the line spread function that was derived from the laser slit image after deconvolution provided a measurement of intraocular light scatter. The deconvolution technique was applied to images obtained in a group of 13 patients (mean age +/- I standard deviation: 42 +/- 12 years) with retinitis pigmentosa (RP), a retinal disease in which, by clinical examination, changes in the lens of the eye can be manifested. Measurements were compared with those obtained from 20 visually normal control subjects (mean age +/- 1 standard deviation: 43 +/- 17 years). Results. Combined higher-order aberrations and light scatter, measured as the area under the line spread function derived from the laser slit image, were increased significantly in the patients with RP as compared with the control subjects (p = 0.004). Ocular higher-order aberrations obtained from the Shack-Hartmann images were higher in the patients with RP than in the control subjects (p = 0.05). Intraocular light scatter derived from the deconvolved laser slit image was significantly higher in the patients with RP than in the control subjects (p = 0.009). Minimizing the contribution of ocular higher-order aberrations by deconvolution reduced the area under the line spread function in the control subjects and patients with RP, denoting an improvement in retinal image quality. Conclusions. A method for differentiating ocular higher-order aberrations and intraocular light scatter based on deconvolution was developed that may be useful for determining the level of improvement in retinal image quality that can be anticipated by the application of adaptive optics to aging and diseased human eyes.
引用
收藏
页码:976 / 980
页数:5
相关论文
共 50 条
  • [41] Validation of Mahajan's formula for scaling ocular higher-order aberrations by pupil size
    Wallace, Henry B.
    Misra, Stuti L.
    McKelvie, James
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (06) : 1067 - 1072
  • [42] Ocular higher-order aberrations and axial eye growth in young Hong Kong children
    Jason K. Lau
    Stephen J. Vincent
    Michael J. Collins
    Sin-Wan Cheung
    Pauline Cho
    Scientific Reports, 8
  • [43] Ocular Higher-Order Wavefront Aberrations in the Japanese Adult Population: the Yamagata Study (Funagata)
    Namba, Hiroyuki
    Kawasaki, Ryo
    Narumi, Mari
    Sugano, Akira
    Homma, Kei
    Nishi, Katsuhiro
    Murakami, Takanori
    Kato, Takeo
    Kayama, Takamasa
    Yamashita, Hidetoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (01) : 90 - 97
  • [44] Ocular higher-order aberrations and contrast sensitivity after conventional laser in situ keratomileusis
    Yamane, N
    Miyata, K
    Samejima, T
    Hiraoka, T
    Kiuchi, T
    Okamoto, F
    Hirobara, Y
    Mihashi, T
    Oshika, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (11) : 3986 - 3990
  • [45] Ocular higher-order aberrations and contrast visual function after laser in situ keratomileusis
    Yamane, N
    Sato, M
    Hiraoka, T
    Okamoto, F
    Kaji, Y
    Oshika, T
    Samejima, T
    Miyata, K
    Hirohara, Y
    Mihashi, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U25 - U25
  • [46] Evaluation of Ocular Higher-Order Aberrations in First-Degree Relatives of Patients With Keratoconus
    Namdari, Maral
    Eslampour, Alireza
    Zarei-Ghanavati, Siamak
    CORNEA, 2023, 42 (03) : 308 - 312
  • [47] Contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes
    Oshika, Tetsuro
    Okamoto, Chikako
    Samejima, Tomokazu
    Tokunaga, Tadatoshi
    Miyata, Kazunori
    OPHTHALMOLOGY, 2006, 113 (10) : 1807 - 1812
  • [48] Ocular higher-order aberrations and mesopic pupil size in individuals screened for refractive surgery
    Seyed Javad Hashemian
    Mohammad Soleimani
    Alireza Foroutan
    Mahmood Joshaghani
    Mohammad Jafar Ghaempanah
    Mohammad Ebrahim Jafari
    Mehdi Yaseri
    International Journal of Ophthalmology, 2012, (02) : 222 - 225
  • [49] Changes in ocular higher-order aberrations following botulinum toxin treatment in patients with blepharospasm
    Isshiki, Yoshihiko
    Ishikawa, Hiroto
    Mimura, Osamu
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (06) : 486 - 491
  • [50] Ocular higher-order aberrations and mesopic pupil size in individuals screened for refractive surgery
    Hashemian, Seyed Javad
    Soleimani, Mohammad
    Foroutan, Alireza
    Joshaghani, Mahmood
    Ghaempanah, Mohammad Jafar
    Jafari, Mohammad Ebrahim
    Yaseri, Mehdi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (02) : 222 - 225