Automated quantification of TSH in serum by a chemiluminescent enzyme immunometric assay: Analytical validation

被引:0
|
作者
Alvarez, MLT [1 ]
AndradeOlivie, MA [1 ]
Garcia, SC [1 ]
Perez, DR [1 ]
Dominguez, AS [1 ]
Sousa, TR [1 ]
Novoa, RA [1 ]
机构
[1] GEN HOSP, CLIN CHEM LAB, VIGO 36201, SPAIN
关键词
immunoassay; chemiluminescence; radioimmunoassay; TSH;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Thyroid stimulating hormone (thyrotropin; TSH) in serum was assayed with the Immulite-TSH, a fully automated solid-phase third-generation immunoassay analyzer that has a chemiluminescent detection system. The intraassay CV ranged from 3.6% to 6.2% for TSH mean concentrations from 0.025 to 32.12 mIU/L and the interassay CV ranged from 7.9% to 10% for TSH mean concentrations between 0.023 and 31.93 mIU/L. The analytical and functional detection limits of the assay were 0.001 and 0.0068 respectively. No interference was observed by any of the compounds: bilirubin, triglycerides, and hemoglobin. To compare the accuracy of Immulite-TSH with that of a conventional immunoradiometric assay (Orion Diagnostica Irma-TSH), we examined 153 patient samples with TSH concentrations ranging approximately 0.2 to 100 mIU/L. Ar TSH concentration similar to 0.15 the precision was greater for Immulite-TSH than for Irma TSH (3.8% vs 11.87%) intraassay CV and (8.6% vs 35.4%) interassay CV. We concluded that Immulite-TSH is a rapid and precise third-generation assay, totally automated and the results can be provided to the clinician within 1 to 2 h of receipt of the patient's sample.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 50 条
  • [1] RAPID, AUTOMATED QUANTIFICATION OF TOTAL HUMAN CHORIONIC-GONADOTROPIN IN SERUM BY A CHEMILUMINESCENT ENZYME IMMUNOMETRIC ASSAY
    VANKRIEKEN, L
    DEHERTOGH, R
    CLINICAL CHEMISTRY, 1995, 41 (01) : 36 - 40
  • [2] Validation of a chemiluminescent enzyme immunometric assay for plasma adrenocorticotropic hormone in the dog
    Scott-Moncrieff, JC
    Koshko, MA
    Brown, JA
    Hill, K
    Refsal, KR
    VETERINARY CLINICAL PATHOLOGY, 2003, 32 (04) : 180 - 187
  • [3] CHEMILUMINESCENT IMMUNOMETRIC ASSAY OF THYROGLOBULIN IN SERUM
    JAIN, A
    HUTCHISON, JS
    HOANG, A
    BLAD, D
    KIANG, JJ
    SPENCER, C
    CLINICAL CHEMISTRY, 1995, 41 (06) : S74 - S75
  • [4] ASSESSMENT OF AN ENHANCED CHEMILUMINESCENT IMMUNOMETRIC ASSAY FOR TSH IN 1127 PATIENTS
    SQUIRE, CR
    GIMLETTE, TMD
    ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 : 419 - 425
  • [5] An automated chemiluminescent immunometric assay for intact ACTH on the IMMULITE system.
    PanosianSahakian, N
    Lei, JD
    Barkley, J
    Sustarsic, D
    ElShami, AS
    CLINICAL CHEMISTRY, 1996, 42 (06) : 388 - 388
  • [6] Evaluation of the analytical performance of an enzyme immunometric assay (EIA) designed to measure endogenous thyroid-stimulating hormone (TSH) in canine serum samples
    Iversen, L
    Hoier, R
    Jensen, AL
    Skydsgaard, M
    Koch, J
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 1998, 45 (02): : 93 - 98
  • [7] DETERMINATION OF ALPHA-FETOPROTEIN IN SERUM WITH AN AUTOMATED IMMUNOMETRIC ASSAY
    VILJA, P
    TANHUANPAA, P
    TUOHIMAA, P
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1988, 26 (05): : 336 - 336
  • [8] Evaluation of an enzyme immunometric assay to measure serum adiponectin concentrations
    Suominen, P
    CLINICAL CHEMISTRY, 2004, 50 (01) : 219 - 221
  • [9] Serum erythropoietin measured by chemiluminescent immunometric assay: An accurate diagnostic test for absolute erythrocytosis
    Mossuz, P
    Girodon, F
    Hermouet, S
    Dobo, I
    Lippert, E
    Donnard, M
    Latger-Cannard, V
    Boiret, N
    Praloran, V
    Lecron, JC
    CLINICAL CHEMISTRY, 2005, 51 (06) : 1018 - 1021
  • [10] AN AUTOMATED CHEMILUMINESCENT IMMUNOMETRIC ASSAY FOR INTERLEUKIN-8 (IL-8) ON THE IMMULITE SYSTEM
    DOSTATNI, R
    PFITZNER, R
    SCHONHARL, G
    KLINGER, W
    SAHAKIAN, N
    SUSTARSIC, D
    ELSHAMI, S