Control of secondary flow in a double-inlet pulse tube refrigerator

被引:0
|
作者
Shiraishi, M. [1 ]
Murakami, M. [2 ]
Nakano, A. [1 ]
Iida, T. [3 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Namiki 1-2-1, Tsukuba, Ibaraki 3058564, Japan
[2] Univ Tsukuba, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki 3058564, Japan
[3] Orbital Engn Co, Kanagawa Ku, Yokohama, Kanagawa 2210822, Japan
来源
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B | 2006年 / 823卷
关键词
pulse tube refrigerator; cryocooler; visualization of secondary flow; DC flow; acoustic streaming;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Secondary flow in a double-inlet pulse tube refrigerator with a double bypass valve configuration was evaluated to determine the advantage of this configuration in controlling the secondary flow over a conventional single valve configuration. In the double-valve configuration two needle valves was connected in parallel and their respective valve directions were in opposite directions, namely, one valve was directed toward the hot end and the other toward the inlet of the regenerator. The effects of valve configuration on the flow behavior of the secondary flow, on the cooling performance, and on the pressure-volume (work) diagram for gas were investigated. The secondary flow was visualized by using a smoke-wire flow visualization technique, and cooling performance was estimated based on the temperature difference between the hot and cold ends. Results showed that the double-valve configuration allowed the operating conditions of the refrigerator to be optimized to maximize the work and minimize the heat loss by the secondary flow, whereas the single-valve configuration did not leave room for such adjustment. After optimization, however, the single-valve configuration still showed fairly good performance, comparable to that of the double-valve configuration.
引用
收藏
页码:27 / +
页数:2
相关论文
共 50 条
  • [31] Comparison of two models of a double inlet miniature pulse tube refrigerator: Part A thermodynamics
    Nika, P
    Bailly, Y
    CRYOGENICS, 2002, 42 (10) : 593 - 603
  • [32] Miniature double-inlet pulse tube cryocooler: Design by thermoacoustic theory compared with preliminary experimental results
    Xiao, JH
    Yang, JH
    Tao, ZD
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1435 - 1441
  • [33] Miniature Double-Inlet Pulse Tube Cryocooler: Design By Thermoacoustic Theory Compared With Preliminary Experimental Results
    Xiao, J. H.
    Yang, J. H.
    Tao, Z. D.
    Advances in Cryogenic Engineering, (41/B):
  • [34] Enthalpy flow rate of a pulse tube in pulse tube refrigerator
    Zhu, SW
    Chen, ZQ
    CRYOGENICS, 1998, 38 (12) : 1213 - 1216
  • [35] Experimental study of the flow field in the double-inlet cyclone
    Xi'an Jianzhu Keji Daxue Xuebao, 3 (275-277):
  • [36] A SINGLE STAGE DOUBLE INLET PULSE TUBE REFRIGERATOR CAPABLE OF REACHING 42K
    ZHU, SW
    WU, PY
    CHEN, ZQ
    ZHU, WX
    ZHOU, YA
    CRYOGENICS, 1990, 30 : 257 - 261
  • [37] A modified two-stage pulse tube cryocooler utilizing double-inlet and multi-mesh regenerator
    Arablu, M.
    Jafarian, A.
    CRYOGENICS, 2013, 58 : 26 - 32
  • [38] Characteristics of the double inlet pulse tube
    de Boer, PCT
    CRYOGENICS, 2003, 43 (07) : 379 - 391
  • [39] Investigation of synchronous effects of multi-mesh regenerator and double-inlet on performance of a Stirling pulse tube cryocooler
    Arablu, M.
    Jafarian, A.
    CRYOGENICS, 2013, 54 : 1 - 9
  • [40] Double-Inlet Left Ventricle
    Rao, P. Syamasundar
    CHILDREN-BASEL, 2022, 9 (09):