Control of secondary flow in a double-inlet pulse tube refrigerator

被引:0
|
作者
Shiraishi, M. [1 ]
Murakami, M. [2 ]
Nakano, A. [1 ]
Iida, T. [3 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Namiki 1-2-1, Tsukuba, Ibaraki 3058564, Japan
[2] Univ Tsukuba, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki 3058564, Japan
[3] Orbital Engn Co, Kanagawa Ku, Yokohama, Kanagawa 2210822, Japan
来源
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B | 2006年 / 823卷
关键词
pulse tube refrigerator; cryocooler; visualization of secondary flow; DC flow; acoustic streaming;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Secondary flow in a double-inlet pulse tube refrigerator with a double bypass valve configuration was evaluated to determine the advantage of this configuration in controlling the secondary flow over a conventional single valve configuration. In the double-valve configuration two needle valves was connected in parallel and their respective valve directions were in opposite directions, namely, one valve was directed toward the hot end and the other toward the inlet of the regenerator. The effects of valve configuration on the flow behavior of the secondary flow, on the cooling performance, and on the pressure-volume (work) diagram for gas were investigated. The secondary flow was visualized by using a smoke-wire flow visualization technique, and cooling performance was estimated based on the temperature difference between the hot and cold ends. Results showed that the double-valve configuration allowed the operating conditions of the refrigerator to be optimized to maximize the work and minimize the heat loss by the secondary flow, whereas the single-valve configuration did not leave room for such adjustment. After optimization, however, the single-valve configuration still showed fairly good performance, comparable to that of the double-valve configuration.
引用
收藏
页码:27 / +
页数:2
相关论文
共 50 条
  • [1] NUMERICAL-ANALYSIS OF DOUBLE-INLET PULSE TUBE REFRIGERATOR
    WANG, C
    WU, PY
    CHEN, ZQ
    CRYOGENICS, 1993, 33 (05) : 526 - 530
  • [2] Visualization of secondary flow in tapered double-inlet pulse tube refrigerators
    Shiraishi, M
    Murakami, M
    Nakano, A
    CRYOCOOLERS 13, 2005, : 313 - 322
  • [3] Visualization study of the local flow field in an orifice and double-inlet pulse tube refrigerator
    Shiraishi, M
    Nakamura, N
    Takamatsu, K
    Murakami, M
    Nakano, A
    CRYOCOOLERS 10, 1999, : 329 - 336
  • [4] Research of pulse tube refrigerator with high and low temperature double-inlet
    Yang, LW
    Zhou, Y
    Liang, JT
    CRYOGENICS, 1999, 39 (05) : 417 - 423
  • [5] Research of pulse tube refrigerator with high and low temperature double-inlet
    Cryogenic Laboratory, Chinese Acad. Sci., Post B., Beijing, China
    Cryogenics, 5 (417-423):
  • [6] Visualization of oscillating flow in a double-inlet pulse tube refrigerator with a diaphragm inserted in a bypass-tube
    Shiraishi, Masao
    Murakami, Masahide
    CRYOGENICS, 2012, 52 (7-9) : 410 - 415
  • [7] THEORETICAL AND EXPERIMENTAL STUDIES OF A DOUBLE-INLET REVERSIBLE PULSE TUBE REFRIGERATOR
    WANG, C
    WU, PY
    CHEN, ZQ
    CRYOGENICS, 1993, 33 (06) : 648 - 652
  • [8] Impact of Gedeon streaming on the efficiency of a double-inlet pulse tube refrigerator
    Tang, Ke
    Feng, Ye
    Jin, Tao
    Jin, Shenghan
    Yang, Rui
    APPLIED THERMAL ENGINEERING, 2017, 111 : 445 - 454
  • [9] Simultaneous Analytical Solution of the Complete System of Double-Inlet Pulse Tube Refrigerator
    Ghahremani, A. R.
    Saidi, M. H.
    Ebrahimian, M.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2012, 26 (02) : 337 - 344
  • [10] An adiabatic model for a two-stage double-inlet pulse tube refrigerator
    Shafi, K. A.
    Rasheed, K. K. A.
    George, J. M.
    Sajid, N. K. M.
    Kasthurirengan, S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (07) : 1247 - 1252