Physical Model-Based Metal Artifact Reduction (MAR) Scheme for a 3D Cone-Beam CT Extremity Imaging System

被引:1
|
作者
Yang, D. [1 ]
Senn, R. A. [1 ]
Packard, N. [1 ]
Richard, S. [1 ]
Yorkston, J. [1 ]
机构
[1] Carestream Hlth Inc, Res & Innovat Labs, Rochester, NY 14615 USA
关键词
CBCT imaging system; CBCT metal artifacts reduction; image reconstruction; COMPUTED-TOMOGRAPHY; ALGORITHM;
D O I
10.1117/12.2006207
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In Cone Beam CT Imaging, metallic and other dense objects, such as implantable orthopedic appliances, surgical clips and staples, and dental fillings, are often acquired as part of the image dataset. These high-density, high atomic mass objects attenuate X-rays in the diagnostic energy range much more strongly than soft tissue or bony structures, resulting in photon starvation at the detector. In addition, signal behind the metal objects suffer from increased quantum noise, scattered radiation, and beam hardening. All of these effects combine to create nonlinearities which are further amplified by the reconstruction algorithm, such as conventional filtered back-projection (FBP), producing strong artifacts in the form of streaking. They reduce image quality by masking soft tissue structures, not only in the immediate vicinity of the dense object, but also throughout the entire image volume. A novel, physical-model-based, metal-artifact reduction scheme (MAR) is proposed to mitigate the metal-induced artifacts. The metal objects are segmented in the projection domain, and a physical model based method is adopted to fill in the segmented area. The FDK1 reconstruction algorithm is then used for the final reconstruction.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Known-component metal artifact reduction (KC-MAR) for cone-beam CT
    Uneri, A.
    Zhang, X.
    Yi, T.
    Stayman, J. W.
    Helm, P. A.
    Osgood, G. M.
    Theodore, N.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):
  • [2] Model-Based Approach to Minimize System Calibrations for 3D Reconstruction Quality of a Cone-Beam CT System
    van der Maas, Rick
    Dries, Johan
    de Jager, Bram
    Steinbuch, Maarten
    2013 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), 2013, : 140 - 145
  • [3] Metal Artifact Reduction in Cone-beam CT by Constrained Optimization
    Zhang, X.
    Wang, J.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S652 - S652
  • [4] Dedicated Cone-Beam CT System for Extremity Imaging
    Carrino, John A.
    Al Muhit, Abdullah
    Zbijewski, Wojciech
    Thawait, Gaurav K.
    Stayman, J. Webster
    Packard, Nathan
    Senn, Robert
    Yang, Dong
    Foos, David H.
    Yorkston, John
    Siewerdsen, Jeffrey H.
    RADIOLOGY, 2014, 270 (03) : 816 - 824
  • [5] METAL ARTIFACT REDUCTION IN CONE-BEAM EXTREMITY IMAGES USING GATED CONVOLUTIONS
    Agrawal, Harshit
    Hietanen, Ari
    Sarkka, Simo
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1087 - 1090
  • [6] A 3D metal artifact correction method in cone-beam CT bone imaging by using an implant image library
    Zhang, Yan
    Ning, Ruola
    Conover, David
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [7] Evaluation of Software-Based Metal Artifact Reduction in Intraoperative 3D Imaging of the Spine Using a Mobile Cone Beam CT
    Maxim Privalov
    Marcus Mohr
    Benedict Swartman
    Nils Beisemann
    Holger Keil
    Jochen Franke
    Paul Alfred Grützner
    Sven Yves Vetter
    Journal of Digital Imaging, 2020, 33 : 1136 - 1143
  • [8] Evaluation of Software-Based Metal Artifact Reduction in Intraoperative 3D Imaging of the Spine Using a Mobile Cone Beam CT
    Privalov, Maxim
    Mohr, Marcus
    Swartman, Benedict
    Beisemann, Nils
    Keil, Holger
    Franke, Jochen
    Gruetzner, Paul Alfred
    Vetter, Sven Yves
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (05) : 1136 - 1143
  • [9] Metal Artifact Reduction based on 2D-Projection Correction for Dental Cone-beam CT Images
    Narkbuakaew, Walita
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [10] Penalized-Likelihood Reconstruction for Metal Artifact Reduction in Cone-Beam CT
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2733 - 2736