The pull-out test on knit bamboo reinforcement embedded into concrete beam

被引:0
|
作者
Nuralinah, Devi [1 ]
机构
[1] Brawijaya Univ, Dept Civil Engn, Mt Hartono 65145 167, Malang, Indonesia
关键词
D O I
10.1051/matecconf/201925801007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The pull-out test is generally conducted to obtain accurately the carrying capacity of the flexural strength of the knit bamboo reinforced concrete beam, which is more determined by the bonding strength than the tensile strength of reinforcement in concrete. Bamboo bar with braid knit which was coated with sikadur as bonding agent based on selected epoxy resin was expected to improve a good friction with concrete. In the pull-out test method, a hydraulic jack was applied to encourage bamboo embedded into a pair of concrete blocks, whose size was 15cm x 30cm x 40cm. The experimental variable of specimens were types of knitted bamboo, and type of coating. Based on the test results, either the bond strength or the tensile strength, which was calculated based on the failure mechanism, increased with respect to the concrete quality. The compressive strength of concrete was averaged as much as 25,97 MPa. The usage of outer skin surface on the cutting braid knit bamboo (type 1), which was coated with sikadur experimentally could increase the pull-out load. In the pull-out test, bond failure occurred with using of the plain bamboo bar with the bond stress of 1.18 MPa, while tensile failure occurred with using of knit bar type 1 with peak tensile strength of 85.84 Mpa.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Influence of Fiber Embedded Length on Properties of Single Fiber Pull-out Test
    Zhang Yafang
    Chen Peiran
    Liu Hao
    Wu Qing-hua
    ADVANCED CONSTRUCTION TECHNOLOGIES, 2014, 919-921 : 2061 - 2070
  • [32] Numerical Study of the Bond Strength Evolution of Corroded Reinforcement in Concrete in Pull-Out Tests
    El Alami, Eliass
    Fekak, Fatima-Ezzahra
    Garibaldi, Luigi
    Moustabchir, Hassane
    Elkhalfi, Ahmed
    Scutaru, Maria Luminita
    Vlase, Sorin
    APPLIED SCIENCES-BASEL, 2022, 12 (02):
  • [33] MODEL FOR PULL-OUT STRENGTH OF ANCHORS IN CONCRETE
    PEIER, WH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1983, 109 (05): : 1155 - 1173
  • [34] Pull-out behavior of polymer fibers in concrete
    Sigruener, Michael
    Huesken, Goetz
    Pirskawetz, Stephan
    Herz, Jonas
    Muscat, Dirk
    Struebbe, Nicole
    JOURNAL OF POLYMER SCIENCE, 2023, 61 (21) : 2708 - 2720
  • [35] Effect of Headed Stud Thickness Embedded in Steel Fiber Concrete on Pull-Out Strength
    Nzambi, Aaron Kadima Lukanu Lwa
    de Oliveira, Denio Ramam Carvalho
    Moraes, Heber Dioney Sousa
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2024, 29 (02)
  • [36] Pull-out test of anchor bolt for fastening lead damper to concrete foundation
    Asada H.
    Kishiki S.
    Wada A.
    Journal of Structural and Construction Engineering, 2010, 75 (649): : 661 - 669
  • [37] Influence of high temperature heating on pull-out properties of mechanical anchor embedded in concrete
    Matsuzawa, Koichi
    Kitsutaka, Yoshinori
    Katta, Akihiko
    Journal of Structural and Construction Engineering, 2015, 80 (707): : 29 - 37
  • [38] Pull-out behaviour of headed studs embedded in normal weight concrete at low temperatures
    Xie, Jian
    Kang, Er-Cong
    Yan, Jia-Bao
    Zhu, Guan-Ru
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 264
  • [39] PULL-OUT BEHAVIOUR OF EMBEDDED BLIND BOLTS IN CONCRETE-FILLED STEEL TUBES
    Xu, Fei
    Chan, Tak-Ming
    Young, Ben
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1097 - 1106
  • [40] Fibre reinforced concrete in flexure and single fibre pull-out test: a correlation
    Manca, M.
    Ciancio, D.
    Dight, P.
    FIBRE CONCRETE 2017, 2017, 246