The pull-out test on knit bamboo reinforcement embedded into concrete beam

被引:0
|
作者
Nuralinah, Devi [1 ]
机构
[1] Brawijaya Univ, Dept Civil Engn, Mt Hartono 65145 167, Malang, Indonesia
关键词
D O I
10.1051/matecconf/201925801007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The pull-out test is generally conducted to obtain accurately the carrying capacity of the flexural strength of the knit bamboo reinforced concrete beam, which is more determined by the bonding strength than the tensile strength of reinforcement in concrete. Bamboo bar with braid knit which was coated with sikadur as bonding agent based on selected epoxy resin was expected to improve a good friction with concrete. In the pull-out test method, a hydraulic jack was applied to encourage bamboo embedded into a pair of concrete blocks, whose size was 15cm x 30cm x 40cm. The experimental variable of specimens were types of knitted bamboo, and type of coating. Based on the test results, either the bond strength or the tensile strength, which was calculated based on the failure mechanism, increased with respect to the concrete quality. The compressive strength of concrete was averaged as much as 25,97 MPa. The usage of outer skin surface on the cutting braid knit bamboo (type 1), which was coated with sikadur experimentally could increase the pull-out load. In the pull-out test, bond failure occurred with using of the plain bamboo bar with the bond stress of 1.18 MPa, while tensile failure occurred with using of knit bar type 1 with peak tensile strength of 85.84 Mpa.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Pull-out of textile reinforcement in concrete
    Portal, Natalie Williams
    Fernandez Perez, Ignasi
    Thrane, Lars Nyholm
    Lundgren, Karin
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 71 : 63 - 71
  • [2] Pull-out behaviour of reinforcement embedded in self-compacting concrete
    Daoud, A
    Lorrain, M
    Elgonnouni, M
    MATERIALS AND STRUCTURES, 2002, 35 (251) : 395 - 401
  • [3] Pull-out test study on the bamboo reinforcement-rammed earth interface
    Luo Y.
    Ye C.
    Zhong H.
    Zeng Z.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2023, 53 (05): : 915 - 925
  • [4] Interfacial Characterization by Pull-Out Test of Bamboo Fibers Embedded in Poly(Lactic Acid)
    Viel, Quentin
    Esposito, Antonella
    Saiter, Jean-Marc
    Santulli, Carlo
    Turner, Joseph A.
    FIBERS, 2018, 6 (01):
  • [5] Pull-out resistance of stud groups embedded in concrete
    Lai, Zhichao
    Han, Ying
    Yang, Xiaoqiang
    Wang, Ying
    Li, Qiang
    STRUCTURES, 2023, 47 : 1383 - 1395
  • [6] Pull-out test analysis for geo-reinforcement
    Department of Civil Engineering, Saga University, Saga 840-8502, Japan
    Geotext. Geomembr., 3 (157-170):
  • [7] EXPERIMENTAL INVESTIGATION OF BOND BETWEEN GFRP REINFORCEMENT AND CONCRETE USING PULL-OUT TEST
    Holly, I.
    Gazovicova, N.
    ENGINEERING MECHANICS 2018 PROCEEDINGS, VOL 24, 2018, : 309 - 312
  • [8] Pull-out strength of bars embedded in high performance concrete
    Hamouine, A
    Lorrain, M
    MATERIALS AND STRUCTURES, 1995, 28 (184): : 569 - 574
  • [9] Pull-out mechanisms of twisted steel fibers embedded in concrete
    Naaman, AE
    Sujivorakul, C
    SHOTCRETE: ENGINEERING DEVELOPMENTS, 2001, : 197 - 203
  • [10] The bonding strength of GFRP bars embedded within concrete under direct pull-out test
    Kusnadi
    Djamaluddin, R.
    Muhiddin, B.
    Irmawaty, R.
    3RD INTERNATIONAL CONFERENCE ON CIVIL AND ENVIRONMENTAL ENGINEERING (ICCEE 2019), 2020, 419