A Wireless Passive pH Sensor With Clutter Rejection Scheme

被引:18
|
作者
Mondal, Saikat [1 ]
Kumar, Deepak [1 ]
Chahal, Premjeet [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48823 USA
关键词
pH; phase shifter; sensor; harmonic; wireless;
D O I
10.1109/JSEN.2019.2893869
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the design and development of a passive wireless pH sensor tag. Under wireless interrogation, the sensor tag changes the phase of the interrogation signal according to the pH. The conversion of pH data into phase information was implemented using a pH electrode coupled to a phase shifter. A theoretical study was performed on the varactor diode parameters to design a highly linear and sensitive phase response with pH change. In addition, a dual frequency operation was implemented based on fundamental interrogation frequency at 2 GHz and the sensor tag reply at the second harmonic (4 GHz) to reduce the clutter effect. The harmonic frequency was generated using a double-balanced frequency multiplier with a conversion loss of 12.2 dB at received input power of 0 dBm. The harmonic sensor tag sends back the phase information at 4 GHz, which is down-converted and read using a phase measurement reader. In addition to the clutter rejection, the harmonic implementation also helps with improved sensitivity. Different pH solutions from 4 to 10 were used to characterize the sensor tag. A linear phase response of 2.32 (degree/pH) was obtained experimentally at a standoff distance of 18 cm from the reader. The design and implementation of the passive pH sensor were validated with simulation and measurement results.
引用
收藏
页码:3399 / 3407
页数:9
相关论文
共 50 条
  • [21] A Wireless Passive pH Sensor for Real-Time In Vivo Milk Quality Monitoring
    Bhadra, S.
    Thomson, D. J.
    Bridges, G. E.
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 769 - 772
  • [22] A Wireless, Passive pH Sensor Based on Magnetic Higher-Order Harmonic Fields
    Horton, Brock E.
    Pereles, Brandon D.
    Tan, Ee Lim
    Ong, Keat Ghee
    SENSOR LETTERS, 2009, 7 (04) : 599 - 604
  • [23] Passive resonators for wireless passive sensor readout enhancement
    Sanz, Diego A.
    Mitrosbaras, Costantino
    Unigarro, Edgar A.
    Segura-Quijano, Fredy
    APPLIED PHYSICS LETTERS, 2013, 103 (13)
  • [24] Reference Signal Trusted Reconstruction for Passive Radar Based on Optimal Clutter Rejection
    Zhang Xun
    Wan Xianrong
    Yi Jianxin
    Gong Ziping
    JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2021, 43 (11) : 3193 - 3200
  • [25] A passive wireless integrated humidity sensor
    Harpster, TJ
    Stark, B
    Najafi, K
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 95 (2-3) : 100 - 107
  • [26] Passive Diagnosis for Wireless Sensor Networks
    Liu, Yunhao
    Liu, Kebin
    Li, Mo
    IEEE-ACM TRANSACTIONS ON NETWORKING, 2010, 18 (04) : 1132 - 1144
  • [27] Passive Diagnosis for Wireless Sensor Networks
    Liu, Kebin
    Li, Mo
    Liu, Yunhao
    Li, Minglu
    Guo, Zhongwen
    Hong, Feng
    SENSYS'08: PROCEEDINGS OF THE 6TH ACM CONFERENCE ON EMBEDDED NETWORKED SENSOR SYSTEMS, 2008, : 113 - 126
  • [28] A Wireless and Passive Implantable Pressure Sensor
    Tan, Ee Lim
    Pereles, Brandon D.
    Ong, Keat Ghee
    SENSOR LETTERS, 2009, 7 (01) : 57 - 63
  • [29] Wireless interrogation of passive crack sensor
    Xu, Z.
    Jia, Y.
    Valentin, R.
    Portela, G.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 4012 - 4018
  • [30] Designing a Passive Retrodirective Wireless Sensor
    Islam, Md. Mazidul
    Rasilainen, Kimmo
    Karki, Sabin Kumar
    Viikari, Ville
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2017, 16 : 1739 - 1742