Development, validation and application of a coupled reduced-order CFD model for building control applications

被引:24
|
作者
Kim, D. [1 ]
Braun, J. E. [1 ]
Cliff, E. M. [2 ]
Borggaard, J. T. [2 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Virginia Tech, Interdisciplinary Ctr Appl Math, Blacksburg, VA USA
关键词
Reduced-order model; CFD; Coupled model; Building model; Building control; RTU; ENERGY SIMULATION; TEMPERATURE; PERFORMANCE; VENTILATION; PROGRAMS; SYSTEMS; BES;
D O I
10.1016/j.buildenv.2015.05.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Small-to-moderate sized commercial buildings commonly use rooftop units (RTUs) to provide indoor comfort. These applications are often characterized by significant spatial variations in comfort due to poor thermostat placement and poor coordination of RTUs leading to high energy and demand costs and marginal comfort. Tools are needed that can assess both energy and comfort performance for these types of applications so that the benefits of improved RTU coordination and control can be evaluated in terms of energy and comfort and so that appropriate real-time strategies can be developed. In this paper we discuss a method for generating and coupling tractable reduced order models for the building envelope and for the indoor air dynamics. Overall assessments of the coupled model are performed for a typical sit down restaurant that employs four rooftop units. Measurements are available from the site to validate the models. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:97 / 111
页数:15
相关论文
共 50 条
  • [41] Resolved CFD-DEM simulation of blood flow with a reduced-order RBC model
    Achuth Nair Balachandran Nair
    Stefan Pirker
    Mahdi Saeedipour
    Computational Particle Mechanics, 2022, 9 : 759 - 774
  • [42] Application of reduced-order models based on PCA & Kriging for the development of digital twins of reacting flow applications
    Aversano, Gianmarco
    Bellemans, Aurelie
    Li, Zhiyi
    Coussement, Axel
    Gicquel, Olivier
    Parente, Alessandro
    COMPUTERS & CHEMICAL ENGINEERING, 2019, 121 : 422 - 441
  • [43] Validating a Reduced-Order Model for Synthetic Jet Actuators Using CFD and Experimental Data
    Persoons, Tim
    Cressall, Rick
    Alimohammadi, Sajad
    ACTUATORS, 2018, 7 (04)
  • [44] Eigenvector approach for reduced-order optimal control problems of weakly coupled systems
    Kecman, Vojislav
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13 (05): : 569 - 586
  • [45] A comparison of reduced-order modelling techniques for application in hyperthermia control and estimation
    Bailey, EA
    Dutton, AW
    Mattingly, M
    Devasia, S
    Roemer, RB
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1998, 14 (02) : 135 - 156
  • [46] Dynamic analysis of tall building using reduced-order continuum model - Discussion
    Bensalem, A
    JOURNAL OF STRUCTURAL ENGINEERING, 1998, 124 (09) : 1090 - 1090
  • [47] Development and application of reduced-order modeling procedures for subsurface flow simulation
    Cardoso, M. A.
    Durlofsky, L. J.
    Sarma, P.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2009, 77 (09) : 1322 - 1350
  • [48] Development of reduced-order thermal stratification model for upper plenum of a lead-bismuth fast reactor based on CFD
    Yang, Tao
    Zhao, Pengcheng
    Zhao, Yanan
    Yu, Tao
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (08) : 2835 - 2843
  • [49] REDUCED-ORDER MODELING FOR HYPERTHERMIA CONTROL
    POTOCKI, JK
    THARP, HS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) : 1265 - 1273
  • [50] Development of Reduced-Order Thermal Stratification Model for Upper Plenum of Lead-Bismuth Fast Reactor Based on CFD
    Yang T.
    Zhao P.
    Zhao Y.
    Yu T.
    Hedongli Gongcheng/Nuclear Power Engineering, 2023, 44 (02): : 48 - 53