Accuracy combining different brands of implants and abutments

被引:14
|
作者
Sola-Ruiz, Maria-Fernanda [1 ]
Selva-Otaolaurruchi, Eduardo [1 ]
Senent-Vicente, Gisela [1 ]
Gonzalez-de-Cossio, Ines [1 ]
Amigo-Borras, Vicente [2 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Buccofacial Prosthet, E-46003 Valencia, Spain
[2] Univ Politecn Valencia, Dept Mech & Mat Engn, Valencia, Spain
来源
关键词
Vertical fit; implant; prosthetic abutment; combination; MARGINAL FIT; INTERFACE; MISFIT; PROSTHESES; STABILITY;
D O I
10.4317/medoral.18137
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S. A. (Barcelona, Spain), 3i Biomet (Palm Beach, U. S. A.), BTI (Alava, Spain) and Nobel Biocare (Goteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to-abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands, with or without mechanical torque, using SEM micrographs at 5000X. Image analysis was performed using NIS-Elements software (Nikon Instruments Europe B. V.). Results: Before applying torque, vertical misfit (microgaps) of the different combinations tested varied between 1.6 and 5.4 microns and after applying torque, between 0.9 and 5.9 microns, an overall average of 3.46 +/- 2.96 microns. For manual assembly without the use of mechanical torque, the best results were obtained with the combination of the 3i implant and the BTI abutment. The Nobel implant and Nobel abutment, 3i-3i and BTI-BTI and the combination of 3i implant with BTI or Nobel abutment provided the best vertical fit when mechanical torque was applied. Conclusions: The vertical fits obtained were within the limits considered clinically acceptable. The application of mechanical torque improved outcomes. There is compatibility between implants and abutments of different brand and so their combination is a clinical possibility.
引用
收藏
页码:E332 / E336
页数:5
相关论文
共 50 条
  • [21] Combining different metadata views for better recommendation accuracy
    D'Addio, Rafael M.
    Marinho, Ronnie S.
    Manzato, Marcelo G.
    INFORMATION SYSTEMS, 2019, 83 : 1 - 12
  • [22] Compressive Resistances and Failure Modes of Abutments With Different Transgingival Heights and Types on Internal Conical Connected Implants
    Zhu, Chenyuan
    Zhang, Fuqiang
    Jiao, Ting
    IMPLANT DENTISTRY, 2017, 26 (05) : 682 - 689
  • [23] Accuracy of Different Impression Techniques for Internal-Connection Implants
    Lee, Yun-Jung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 823 - 830
  • [24] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [26] Comparison of the Accuracy of Different Transfer Impression Techniques for Osseointegrated Implants
    Zen, Bruno Massucato
    Soares, Eveline Freitas
    Rodrigues, Mariana Agustinho
    Luthi, Leonardo Flores
    Consani, Rafael Leonardo X.
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 662 - 667
  • [27] Mechanical Behavior of Five Different Morse Taper Implants and Abutments with Different Conical Internal Connections and Angles: An In Vitro Experimental Study
    Caballero, Claudia
    Rodriguez, Fernando
    Cortellari, Guillermo Castro
    Scarano, Antonio
    Prados-Frutos, Juan Carlos
    De Aza, Piedad N.
    Fernandes, Gustavo Vicentis Oliveira
    Gehrke, Sergio Alexandre
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (07)
  • [28] Ceramic abutments and ceramic oral implants. An update
    Kohal, Ralf-J.
    Att, Wael
    Baechle, Maria
    Butz, Frank
    PERIODONTOLOGY 2000, 2008, 47 : 224 - 243
  • [29] Soft Tissue Stability with Immediate Implants and Concave Abutments
    Redemagni, Marco
    Cremonesi, Sergio
    Garlini, Giuliano
    Maiorana, Carlo
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2009, 4 (04): : 328 - 337
  • [30] The Surface Conditions and Composition of Titanium Alloys in Implantology: A Comparative Study of Dental Implants of Different Brands
    Tchinda, Alex Perez
    Pierson, Gael
    Kouitat-Njiwa, Richard
    Bravetti, Pierre
    MATERIALS, 2022, 15 (03)