Segmentation and Visualization of a Large, High-Resolution Micro-CT Data of Mice

被引:9
|
作者
Chityala, Ravishankar [1 ]
Pudipeddi, Sridevi [2 ]
Arensten, Luke [3 ]
Hui, Susanta [3 ,4 ]
机构
[1] Univ Minnesota, Minnesota Supercomp Inst, Minneapolis, MN 55455 USA
[2] South Cent Coll, Mankato, MN USA
[3] Univ Minnesota, Dept Therapeut Radiol, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Masonic Canc Ctr, Minneapolis, MN 55455 USA
关键词
Segmentation; Visualization; High resolution; Bone mineral density; SURGICAL MODEL; BEAM;
D O I
10.1007/s10278-012-9498-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-resolution large datasets were acquired to improve the understanding of murine bone physiology. The purpose of this work is to present the challenges and solutions in segmenting and visualizing bone in such large datasets acquired using micro-CT scan of mice. The analyzed dataset is more than 50 GB in size with more than 6,000 2,048x2,048 slices. The study was performed to automatically measure the bone mineral density (BMD) of the entire skeleton. A global Renyi entropy (GREP) method was initially used for bone segmentation. This method consistently oversegmented skeletal region. A new method called adaptive local Renyi entropy (ALREP) is proposed to improve the segmentation results. To study the efficacy of the ALREP, manual segmentation was performed. Finally, a specialized high-end remote visualization system along with the software, VirtualGL, was used to perform remote rendering of this large dataset. It was determined that GREP overestimated the bone cross-section by around 30 % compared with ALREP. The manual segmentation process took 6,300 min for 6,300 slices while ALREP took only 150 min for segmentation. Automatic image processing with ALREP method may facilitate BMD measurement of the entire skeleton in a significantly reduced time, compared with manual process.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [21] Anatomical Variations of the Human Cochlea Determined from Micro-CT and High-Resolution CT Imaging and Reconstruction
    Tang, Jie
    Tang, Xianglong
    Li, Zhenhua
    Liu, Yikang
    Tan, Songhua
    Li, Heng
    Ke, Rongdan
    Wang, Zhi
    Gong, Li
    Tang, Anzhou
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2018, 301 (06): : 1086 - 1095
  • [22] High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data
    Varslot, T.
    Kingston, A.
    Myers, G.
    Sheppard, A.
    MEDICAL PHYSICS, 2011, 38 (10) : 5459 - 5476
  • [23] Iodine staining outperforms phosphotungstic acid in high-resolution micro-CT scanning of post-natal mice cardiac structures
    Doost, Ata
    Arnolda, Leonard
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (02)
  • [24] High-resolution 3D micro-CT imaging of breast microcalcifications: a preliminary analysis
    Willekens, Inneke
    Van de Casteele, Elke
    Buls, Nico
    Temmermans, Frederik
    Jansen, Bart
    Deklerck, Rudi
    de Mey, Johan
    BMC CANCER, 2014, 14
  • [25] Development of 36M-pixel x-ray detector for large field of view and high-resolution micro-CT
    Umetani, Keiji
    Kawata, Yoshiki
    Niki, Noboru
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY IV, 2016, 10020
  • [26] High-resolution 3D micro-CT imaging of breast microcalcifications: a preliminary analysis
    Inneke Willekens
    Elke Van de Casteele
    Nico Buls
    Frederik Temmermans
    Bart Jansen
    Rudi Deklerck
    Johan de Mey
    BMC Cancer, 14
  • [27] High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT
    Nahrendorf, Matthias
    Badea, Cristian
    Hedlund, Laurence W.
    Figueiredo, Jose-Luiz
    Sosnovik, David E.
    Johnson, G. Allan
    Weissleder, Ralph
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 292 (06): : H3172 - H3178
  • [28] High-Resolution Micro-CT for Morphologic and Quantitative Assessment of the Sinusoid in Human Cavernous Hemangioma of the Liver
    Duan, Jinghao
    Hu, Chunhong
    Chen, Hua
    PLOS ONE, 2013, 8 (01):
  • [29] A PIPELINE FOR QUANTITATIVE ANALYSIS OF HIGH-RESOLUTION MICRO-CT OF THE VASCULATURE OF THE FETO-PLACENTAL COTYLEDON
    Jackson, Toby
    Srinivasan, Vijayalaksmi
    Spring, Mary
    James, Jo
    Clark, Alys
    PLACENTA, 2023, 140 : E66 - E66
  • [30] High-resolution micro-CT scanning as an innovative tool for evaluating dental hard tissue development
    Dong, Guangyan
    Dong, Qianqian
    Liu, Yi
    Lou, Beiyan
    Feng, Jin
    Wang, Kejing
    Zhou, Xuedong
    Wu, Hongkun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 335 - 344