Segmentation and Visualization of a Large, High-Resolution Micro-CT Data of Mice

被引:9
|
作者
Chityala, Ravishankar [1 ]
Pudipeddi, Sridevi [2 ]
Arensten, Luke [3 ]
Hui, Susanta [3 ,4 ]
机构
[1] Univ Minnesota, Minnesota Supercomp Inst, Minneapolis, MN 55455 USA
[2] South Cent Coll, Mankato, MN USA
[3] Univ Minnesota, Dept Therapeut Radiol, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Masonic Canc Ctr, Minneapolis, MN 55455 USA
关键词
Segmentation; Visualization; High resolution; Bone mineral density; SURGICAL MODEL; BEAM;
D O I
10.1007/s10278-012-9498-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-resolution large datasets were acquired to improve the understanding of murine bone physiology. The purpose of this work is to present the challenges and solutions in segmenting and visualizing bone in such large datasets acquired using micro-CT scan of mice. The analyzed dataset is more than 50 GB in size with more than 6,000 2,048x2,048 slices. The study was performed to automatically measure the bone mineral density (BMD) of the entire skeleton. A global Renyi entropy (GREP) method was initially used for bone segmentation. This method consistently oversegmented skeletal region. A new method called adaptive local Renyi entropy (ALREP) is proposed to improve the segmentation results. To study the efficacy of the ALREP, manual segmentation was performed. Finally, a specialized high-end remote visualization system along with the software, VirtualGL, was used to perform remote rendering of this large dataset. It was determined that GREP overestimated the bone cross-section by around 30 % compared with ALREP. The manual segmentation process took 6,300 min for 6,300 slices while ALREP took only 150 min for segmentation. Automatic image processing with ALREP method may facilitate BMD measurement of the entire skeleton in a significantly reduced time, compared with manual process.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] Segmentation and Visualization of a Large, High-Resolution Micro-CT Data of Mice
    Ravishankar Chityala
    Sridevi Pudipeddi
    Luke Arensten
    Susanta Hui
    Journal of Digital Imaging, 2013, 26 : 302 - 308
  • [2] High-resolution micro-CT for 3D infarct characterization and segmentation in mice stroke models
    Raquel Pinto
    Jan Matula
    Maria Gomez-Lazaro
    Mafalda Sousa
    Andrea Lobo
    Tomas Zikmund
    Jozef Kaiser
    João R. Gomes
    Scientific Reports, 12
  • [3] High-resolution micro-CT for 3D infarct characterization and segmentation in mice stroke models
    Pinto, Raquel
    Matula, Jan
    Gomez-Lazaro, Maria
    Sousa, Mafalda
    Lobo, Andrea
    Zikmund, Tomas
    Kaiser, Jozef
    Gomes, Joao R.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] High-resolution local imaging using a micro-CT
    Lee, Soo Yeol
    Cho, Min Hyoung
    Choi, Jeong Min
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 137 - 140
  • [5] Fast high-resolution micro-CT with exact reconstruction methods
    Varslot, T.
    Kingston, A.
    Sheppard, A.
    Sakellariou, A.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [6] Deep Learning-Based Segmentation of Mineralized Cartilage and Bone in High-Resolution Micro-CT Images
    Leger, Jean
    Leyssens, Lisa
    De Vleeschouwer, Christophe
    Kerckhofs, Greet
    COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 36 : 158 - 170
  • [7] High-resolution hybrid micro-CT imaging pipeline for mouse brain region segmentation and volumetric morphometry
    Nadkarni, Rohan
    Han, Zay Yar
    Anderson, Robert J.
    Allphin, Alex J.
    Clark, Darin P.
    Badea, Alexandra
    Badea, Cristian T.
    PLOS ONE, 2024, 19 (05):
  • [8] High-resolution in-vivo micro-CT scanner for small animals
    Sasov, A
    Dewaele, D
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 256 - 264
  • [9] High-resolution in-vivo micro-CT scanner for small animals
    Sasov, A
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 705 - 710
  • [10] High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT
    Hu, Jianzhong
    Cao, Yong
    Wu, Tianding
    Li, Dongzhe
    Lu, Hongbin
    MEDICAL PHYSICS, 2014, 41 (10)