ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVELS IN COMPUTED TOMOGRAPHY FOR PAEDIATRIC PATIENTS IN SUDAN: A PILOT STUDY

被引:24
|
作者
Sulieman, A. [1 ,2 ]
机构
[1] Prince Sattam bin Abdulaziz Univ, Coll Appl Sci, Radiol & Med Imaging Dept, Alkharj 11942, Saudi Arabia
[2] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Khartoum, Sudan
关键词
RADIATION-EXPOSURE; CT; 64-SLICE; 16-SLICE; CANCER; HEAD;
D O I
10.1093/rpd/ncv109
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Paediatric patients are recognised to be at higher risk of developing radiation-induced cancer than adults. The purpose of this pilot study was to evaluate the radiation doses to paediatric patients during computed tomography (CT) procedures in order to propose local diagnostic reference levels (DRLs). A total of 296 patients (aged 6-10 y) were investigated in 8 hospitals equipped with 64-, 16- and dual-slice CT machines. The mean dose length product values were 772, 446 and 178 mGy cm for head, abdomen and chest, respectively. Imaging protocols were not adapted to the patient's weight in certain CT machines. The results confirmed that paediatric patients are exposed to an unnecessary radiation dose. The established DRLs were higher than those available in other countries. This study showed the need for harmonisation of the practice in CT departments and radiation dose optimisation.
引用
收藏
页码:91 / 94
页数:4
相关论文
共 50 条
  • [31] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [32] Establishment of Local Diagnostic Reference Level for Routine Paediatric Computed Tomography Examinations in Bafoussam West Cameroon
    Kamdem, Eddy Fotso
    Samba, Odette Ngano
    Manemo, Cedric Tetchoka
    Kouam, Brice Bertrand Foubi
    Abogo, Serge
    Tambe, Joshua
    Amougou, Jean Claude Mballa
    Guegang, Emilienne
    Zeh, Odile Fernande
    Moifo, Boniface
    Nguemgne, Celestine
    Nana, Narcisse Fidele Nwedjiwe
    Fotue, Alain Jerve
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (12) : 815 - 820
  • [33] Diagnostic Reference Level of Paediatric Computed Tomography Brain Examinations
    Abdelaziz, Ikhlas
    BIOSCIENCE RESEARCH, 2021, 18 (01): : 477 - 487
  • [34] Patient size as a parameter for determining Diagnostic Reference Levels for paediatric Computed Tomography (CT) procedures
    Satharasinghe, Duminda
    Jeyasugiththan, Jeyasingam
    Wanninayake, W. M. N. M. B.
    Pallewatte, A. S.
    Samarasinghe, R. A. N. K. K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 102 : 55 - 65
  • [35] Derivation of new diagnostic reference levels for neuro-paediatric computed tomography examinations in Switzerland
    Wagner, Franca
    Bize, Julie
    Racine, Damien
    Le Coultre, Regis
    Verdun, Francis
    Trueb, Philipp R.
    Treier, Reto
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (03) : 1013 - 1036
  • [36] The establishment of local diagnostic reference levels for paediatric interventional cardiology
    McFadden, S.
    Hughes, C.
    D'Helft, C. I.
    McGee, A.
    Rainford, L.
    Brennan, P. C.
    McCrum-Gardner, E.
    Winder, R. J.
    RADIOGRAPHY, 2013, 19 (04) : 295 - 301
  • [37] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Najafi, Mohsen
    Deevband, Mohammad Reza
    Ahmadi, Mohsen
    Kardan, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 603 - 609
  • [38] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [39] Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Jayachandran, Deepa
    Korappil, Noushad
    Tekin, Huseyin O.
    TOMOGRAPHY, 2022, 8 (06) : 2939 - 2945
  • [40] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Mohsen Najafi
    Mohammad Reza Deevband
    Mohsen Ahmadi
    Mohammad Reza Kardan