Hybrid ultra-low-field MRI and magnetoencephalography system based on a commercial whole-head neuromagnetometer

被引:83
|
作者
Vesanen, Panu T. [1 ]
Nieminen, Jaakko O. [1 ]
Zevenhoven, Koos C. J. [1 ]
Dabek, Juhani [1 ]
Parkkonen, Lauri T. [1 ,2 ]
Zhdanov, Andrey V. [1 ,3 ]
Luomahaara, Juho [4 ,5 ]
Hassel, Juha [4 ]
Penttila, Jari [5 ]
Simola, Juha [2 ]
Ahonen, Antti I. [2 ]
Makela, Jyrki P. [3 ]
Ilmoniemi, Risto J. [1 ]
机构
[1] Aalto Univ, Sch Sci, Dept Biomed Engn & Computat Sci, Espoo, Finland
[2] Elekta Oy, Helsinki, Finland
[3] Univ Helsinki, Cent Hosp, HUSLAB, BioMag Lab, Helsinki, Finland
[4] VTT Tech Res Ctr Finland, Espoo, Finland
[5] Aivon Oy, Espoo, Finland
基金
芬兰科学院;
关键词
ultra-low-field MRI; magnetoencephalography; MEG-MRI; superconducting quantum interference device; MICROTESLA MRI; MU-T; BRAIN; CONTRAST; NOISE;
D O I
10.1002/mrm.24413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultra-low-field MRI uses microtesla fields for signal encoding and sensitive superconducting quantum interference devices for signal detection. Similarly, modern magnetoencephalography (MEG) systems use arrays comprising hundreds of superconducting quantum interference device channels to measure the magnetic field generated by neuronal activity. In this article, hybrid MEG-MRI instrumentation based on a commercial whole-head MEG device is described. The combination of ultra-low-field MRI and MEG in a single device is expected to significantly reduce coregistration errors between the two modalities, to simplify MEG analysis, and to improve MEG localization accuracy. The sensor solutions, MRI coils (including a superconducting polarizing coil), an optimized pulse sequence, and a reconstruction method suitable for hybrid MEG-MRI measurements are described. The performance of the device is demonstrated by presenting ultra-low-field-MR images and MEG recordings that are compared with data obtained with a 3T scanner and a commercial MEG device. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1795 / 1804
页数:10
相关论文
共 50 条
  • [21] Utility of Novel Ultra-Low-Field Portable MRI in a Remote Setting in Canada
    Desroche, Chloe
    Innes, Elaine
    Silver, Ian
    Tampieri, Donatella
    Kwan, Benjamin Y. M.
    Jimenez, Johanna Ortiz
    Islam, Omar
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2024,
  • [22] Portable ultra-low-field MRI: scanning new horizons in dementia detection
    Rodda, Joanne
    Dobrzanski, James
    Shergill, Sukhi
    BRITISH JOURNAL OF PSYCHIATRY, 2024, 225 (05) : 506 - 507
  • [23] A low-cost and shielding-free ultra-low-field brain MRI scanner
    Liu, Yilong
    Leong, Alex T. L.
    Zhao, Yujiao
    Xiao, Linfang
    Mak, Henry K. F.
    Tsang, Anderson Chun On
    Lau, Gary K. K.
    Leung, Gilberto K. K.
    Wu, Ed X.
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [24] A low-cost and shielding-free ultra-low-field brain MRI scanner
    Yilong Liu
    Alex T. L. Leong
    Yujiao Zhao
    Linfang Xiao
    Henry K. F. Mak
    Anderson Chun On Tsang
    Gary K. K. Lau
    Gilberto K. K. Leung
    Ed X. Wu
    Nature Communications, 12
  • [25] Current-density imaging using ultra-low-field MRI with adiabatic pulses
    Nieminen, Jaakko O.
    Zevenhoven, Koos C. J.
    Vesanen, Panu T.
    Hsu, Yi-Cheng
    Ilmoniemi, Risto J.
    MAGNETIC RESONANCE IMAGING, 2014, 32 (01) : 54 - 59
  • [26] High-Field-Blinded Assessment of Portable Ultra-Low-Field Brain MRI for Multiple Sclerosis
    Okar, Serhat V.
    Nair, Govind
    Kawatra, Karan D.
    Thommana, Ashley A.
    Donnay, Corinne A.
    Gaitan, Maria I.
    Stein, Joel M.
    Reich, Daniel S.
    JOURNAL OF NEUROIMAGING, 2025, 35 (01)
  • [27] Evaluating the Performance of Ultra-Low-Field MRI for in-vivo 3D Current Density Imaging of the Human Head
    Hoemmen, Peter
    Maekinen, Antti J.
    Hunold, Alexander
    Machts, Rene
    Haueisen, Jens
    Zevenhoven, Koos C. J.
    Ilmoniemi, Risto J.
    Koerber, Rainer
    FRONTIERS IN PHYSICS, 2020, 8
  • [28] Ultra-Low-Field Portable MRI and Extracorporeal Membrane Oxygenation: Preclinical Safety Testing
    Kang, Jin Kook
    Etchill, Eric
    Verdi, Kate
    Velez, Ana K.
    Kearney, Sean
    Dodd-o, Jeffrey
    Bush, Errol
    By, Samantha
    Boskamp, Eddy
    Wilcox, Christopher
    Choi, Chun Woo
    Kim, Bo Soo
    Whitman, Glenn J. R.
    Cho, Sung-Min
    CRITICAL CARE EXPLORATIONS, 2024, 6 (10)
  • [29] Very Low Field MRI: a fast system compatible with Magnetoencephalography
    Galante, A.
    Catallo, N.
    Sebastiani, P.
    Sotgiu, A.
    Sinibaldi, R.
    De Luca, C.
    Conti, A.
    Pizzella, V
    Romani, G. L.
    Della Penna, S.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 560 - 564
  • [30] SQUID-sensor-based ultra-low-field MRI calibration with phantom images: Towards quantitative imaging
    Dabek, Juhani
    Vesanen, Panu T.
    Zevenhoven, Koos C. J.
    Nieminen, Jaakko O.
    Sepponen, Raimo
    Ilmoniemi, Risto J.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 224 : 22 - 31