Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

被引:7
|
作者
Lundqvist, Eva [1 ]
Segelsjo, Monica [1 ]
Andersson, Anna [2 ]
Magnusson, Anders [1 ]
Biglarnia, Ali-Reza [2 ]
机构
[1] Uppsala Univ, Dept Radiol Oncol & Radiat Sci, Sect Radiol, Uppsala, Sweden
[2] Univ Uppsala Hosp, Dept Surg Sci, Sect Transplantat Surg, Uppsala, Sweden
关键词
Computed tomography; volumetry; pancreas transplantation; observer variation; contrast media; KIDNEY; LIVER;
D O I
10.1258/ar.2012.120317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose: To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods: CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results: The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion: CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.
引用
收藏
页码:966 / 972
页数:7
相关论文
共 50 条
  • [21] Intra- and inter-observer reliability of the novel vertebral bone quality score
    Alex Mierke
    Omar Ramos
    Rhett Macneille
    Jun Ho Chung
    Nathaniel Wycliffe
    Wayne Cheng
    Olumide A. Danisa
    European Spine Journal, 2022, 31 : 843 - 850
  • [22] Intra- and Inter-observer Variability in Different Methods of Measuring Carpal Collapse
    Agrawal, S.
    Chabra, T.
    Pandey, S.
    Bhardwaj, P.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2019, 13 (01) : 20 - 24
  • [23] Strategies for dealing with intra- and inter-observer variation in target volume definition
    Holmberg, O
    McClean, B
    McGibney, C
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S202 - S203
  • [24] Intra- and Inter-Observer Reproducibility of Transcatheter Aortic Valve Replacement Planning Measurements by Multidetector Computed Tomography
    Heo, Ran
    Hartaigh, Briain O.
    Cho, Iksung
    Valenti, Valentina
    Leipsic, Jonathon
    Wong, S. Chiu
    Salemi, Arash
    Minutello, Robert M.
    Bergman, Geoffrey
    Mini, James K.
    JOURNAL OF HEART VALVE DISEASE, 2015, 24 (05): : 560 - 569
  • [25] Intra- and inter-observer reliability of perineal body volume measurements with 3-dimensional transperineal ultrasound
    Rahim, A.
    Ahmad, A.
    Tailor, V
    El Shamy, T.
    Bhide, A.
    Digesu, A.
    Fernando, R.
    Khullar, V
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2020, 31 (SUPPL 1) : S103 - S103
  • [26] Intra- and inter-observer reproducibility of QRS duration measurement in CRT patients
    Thebault, C.
    Kervio, G.
    Gervais, R.
    Donal, E.
    Mabo, P.
    Linde, C.
    Daubert, C.
    EUROPEAN HEART JOURNAL, 2010, 31 : 266 - 266
  • [27] Assessment of inter-observer and intra-observer variability in the measurement of QT dispersion
    Bhullar, HK
    Chia, P
    Ong, K
    Ng, WL
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 297 - 300
  • [28] Intra- and inter-observer variability in the evaluation of first trimester placental volume by 3D ultrasound
    Muscat, Jolene
    Chavez, Martin
    Demishev, Michael
    Allaf, Baraa
    Ogburn, Paul
    Vintzileos, Anthony
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (01) : S165 - S166
  • [29] INTRA- AND INTER-OBSERVER VARIATIONS IN ASSESSMENT OF EMPHYSEMA
    THURLBEC.WM
    HOROWITZ, I
    SIEMIATY.J
    DUNNILL, MS
    MAISEL, JC
    PRATT, P
    RYDER, R
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1969, 18 (04): : 646 - &
  • [30] Inter-observer and intra-observer variability in hepatology
    Winkfield, B
    Aubé, C
    Burtin, P
    Calès, P
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2003, 15 (09) : 959 - 966