Impact of rectal balloon-filling materials on the dosimetry of prostate and organs at risk in photon beam therapy

被引:2
|
作者
Srivastava, Shiv P. [1 ,2 ,3 ]
Das, Indra J. [1 ,3 ]
Kumar, Arvind [2 ]
Johnstone, Peter A. S. [3 ]
Cheng, Chee-Wai [1 ,3 ]
机构
[1] Purdue Univ, Dept Hlth Sci, W Lafayette, IN 47907 USA
[2] Reid Hosp & Hlth Care Serv, Dept Radiat Oncol, Richmond, IN USA
[3] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2013年 / 14卷 / 01期
关键词
IMRT; rectal balloon; dosimetry; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; IMMOBILIZATION DEVICE; INTRAFRACTION MOTION; ENDORECTAL BALLOON; DOSE CALCULATION; REAL-TIME; CANCER; IMRT; LOCALIZATION;
D O I
10.1120/jacmp.v14i1.3993
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of rectal balloon in radiotherapy of prostate cancer is shown to be effective in reducing prostate motion and minimizing rectal volume, thus reducing rectal toxicity. Air-filled rectal balloon has been used most commonly, but creates dose perturbation at the air-tissue interface. In this study, we evaluate the effects of rectal balloon-filling materials on the dose distribution to the target and organs at risk. The dosimetric impact of rectal balloon filling was studied in detail for a typical prostate patient, and the general effect of the balloon filling was investigated from a study of ten prostate patients covering a wide range of anterior-posterior and left-right separations, as well as rectal and bladder volumes. Hounsfield units (HU) of the rectal balloon filling was changed from -1000 HU to 1000 HU at an interval of 250 HU, and the corresponding changes in the relative electron density (RED) was calculated. For each of the HU of the rectal balloon filling, a seven-field IMRT plan was generated with 6 MV and 15 MV photon beams, respectively. Dosimetric evaluation was performed with the AAA algorithm for inhomogeneity corrections. A detailed study of the rectal balloon filling shows that the GTV, PTV, rectal, and bladder mean dose decreased with increasing values of RED in the rectal balloon. There is significant underdosage in the target volume at the rectum-prostate interface with an air-filled balloon as compared to that with a water-filled balloon for both 6 MV and 15 MV beams. While the dosimetric effect of the rectal balloon filling is reduced when averaged over ten patients, generally an air-filled balloon results in lower minimum dose and lower mean dose in the overlap region (and possibly the PTV) compared to those produced by water-filled or contrast-filled balloons. Dose inhomogeneity in the target volume is increased with an air-filled rectal balloon. Thus a water-filled or contrast-filled rectal balloon is preferred to an air-filled rectal balloon in EBRT of prostate treatment.
引用
收藏
页码:81 / 91
页数:11
相关论文
共 43 条
  • [21] Multicatheter interstitial brachytherapy versus intensity modulated external beam therapy for accelerated partial breast irradiation: A comparative treatment planning study with respect to dosimetry of organs at risk
    Major, Tibor
    Stelczer, Gabor
    Pesznyak, Csilla
    Meszaros, Norbert
    Polgar, Csaba
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (01) : 17 - 23
  • [22] Impact of multiparametric magnetic resonance imaging on risk group assessment of patients with prostate cancer addressed to external beam radiation therapy
    Pullini, Serena
    Signor, Marco Andrea
    Pancot, Martina
    Zuiani, Chiara
    Bazzocchi, Massimo
    Fongione, Sandro
    Girometti, Rossano
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 764 - 770
  • [23] Using a Further Planning MRI after Neoadjuvant Androgen Deprivation Therapy Significantly Reduces the Radiation Exposure of Organs at Risk in External Beam Radiotherapy of Prostate Cancer
    Merten, Roland
    Fischer, Mirko
    Christiansen, Hans
    Hellms, Susanne
    von Klot, Christoph Alexander Joachim
    Thomas, Nele Henrike
    Knoechelmann, Anne Caroline
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [24] Is an Endorectal Balloon Beneficial for Rectal Sparing after Spacer Implantation in Prostate Cancer Patients Treated with Hypofractionated Intensity-Modulated Proton Beam Therapy? A Dosimetric and Radiobiological Comparison Study
    Ahmad Khalil, Dalia
    Wulff, Joerg
    Jazmati, Danny
    Geismar, Dirk
    Baumer, Christian
    Kramer, Paul-Heinz
    Steinmeier, Theresa
    Schleithoff, Stefanie Schulze
    Tschirdewahn, Stephan
    Hadaschik, Boris
    Timmermann, Beate
    CURRENT ONCOLOGY, 2023, 30 (01) : 758 - 768
  • [25] Use of deformable image registration techniques to estimate dose to organs at risk following prostate external beam radiation therapy and high-dose-rate brachytherapy
    Vozzo, Marie
    Poder, Joel
    Yuen, Johnson
    Bucci, Joseph
    Haworth, Annette
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (01) : 72 - 79
  • [26] Anaysis of the Impact of Setup Uncertainties On Dose to the Organs at the Risk and Plan Robustness Using Normal Tissue Complication Probability in Passive Scattering Proton Beam Therapy
    Wang, J.
    Li, Y.
    Zhang, X.
    Li, H.
    Gillin, M.
    Zhu, X.
    Sahoo, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 2868 - 2868
  • [27] Using Daily Image-Guidance CBCT Scans to Determine the Impact On Delivered Dose From Variations in Bladder and Rectal Filling During IMRT for High-Risk Prostate Cancer
    Martin, W.
    Mynampati, D.
    Bodner, W.
    Garcia, K.
    Hsu, S.
    Yap, J.
    Garg, M.
    Kalnicki, S.
    Tome, W.
    Brodin, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E668 - E668
  • [28] The impact of hormonal therapy when combined with external beam radiotherapy for early-stage intermediate-and high-risk prostate cancer
    Jani, AB
    Basu, A
    Connell III, PP
    Vijayakumar, S
    Abdalla, I
    RADIOLOGY, 2000, 217 : 213 - 213
  • [29] Impact of hormone therapy when combined with external beam radiotherapy for early-stage, intermediate-, or high-risk prostate cancer
    Jani, AB
    Basu, A
    Abdalla, I
    Connell, PP
    Krauz, L
    Vijayakumar, S
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2003, 26 (04): : 382 - 385
  • [30] A Novel Dose Rate Optimization Method to Maximize Ultrahigh-Dose-Rate Coverage of Critical Organs at Risk Without Compromising Dosimetry Metrics in Proton Pencil Beam Scanning FLASH Radiation Therapy
    Zhao, Xingyi
    Huang, Sheng
    Lin, Haibo
    Choi, J. Isabelle
    Zhu, Kun
    Simone, Charles B.
    Yan, Xueqing
    Kang, Minglei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (04): : 1181 - 1191