Impact of rectal balloon-filling materials on the dosimetry of prostate and organs at risk in photon beam therapy

被引:2
|
作者
Srivastava, Shiv P. [1 ,2 ,3 ]
Das, Indra J. [1 ,3 ]
Kumar, Arvind [2 ]
Johnstone, Peter A. S. [3 ]
Cheng, Chee-Wai [1 ,3 ]
机构
[1] Purdue Univ, Dept Hlth Sci, W Lafayette, IN 47907 USA
[2] Reid Hosp & Hlth Care Serv, Dept Radiat Oncol, Richmond, IN USA
[3] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN USA
来源
关键词
IMRT; rectal balloon; dosimetry; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; IMMOBILIZATION DEVICE; INTRAFRACTION MOTION; ENDORECTAL BALLOON; DOSE CALCULATION; REAL-TIME; CANCER; IMRT; LOCALIZATION;
D O I
10.1120/jacmp.v14i1.3993
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of rectal balloon in radiotherapy of prostate cancer is shown to be effective in reducing prostate motion and minimizing rectal volume, thus reducing rectal toxicity. Air-filled rectal balloon has been used most commonly, but creates dose perturbation at the air-tissue interface. In this study, we evaluate the effects of rectal balloon-filling materials on the dose distribution to the target and organs at risk. The dosimetric impact of rectal balloon filling was studied in detail for a typical prostate patient, and the general effect of the balloon filling was investigated from a study of ten prostate patients covering a wide range of anterior-posterior and left-right separations, as well as rectal and bladder volumes. Hounsfield units (HU) of the rectal balloon filling was changed from -1000 HU to 1000 HU at an interval of 250 HU, and the corresponding changes in the relative electron density (RED) was calculated. For each of the HU of the rectal balloon filling, a seven-field IMRT plan was generated with 6 MV and 15 MV photon beams, respectively. Dosimetric evaluation was performed with the AAA algorithm for inhomogeneity corrections. A detailed study of the rectal balloon filling shows that the GTV, PTV, rectal, and bladder mean dose decreased with increasing values of RED in the rectal balloon. There is significant underdosage in the target volume at the rectum-prostate interface with an air-filled balloon as compared to that with a water-filled balloon for both 6 MV and 15 MV beams. While the dosimetric effect of the rectal balloon filling is reduced when averaged over ten patients, generally an air-filled balloon results in lower minimum dose and lower mean dose in the overlap region (and possibly the PTV) compared to those produced by water-filled or contrast-filled balloons. Dose inhomogeneity in the target volume is increased with an air-filled rectal balloon. Thus a water-filled or contrast-filled rectal balloon is preferred to an air-filled rectal balloon in EBRT of prostate treatment.
引用
收藏
页码:81 / 91
页数:11
相关论文
共 43 条
  • [1] Impact of the Use of Endorectal Balloon on Rectal Dosimetry During Stereotactic Body Radiation Therapy of the Prostate
    Wong, A. T.
    Agarwal, M.
    Polubarov, A.
    Safdieh, J.
    Schreiber, D.
    Schwartz, D. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E550 - E550
  • [2] Impact of the use of an endorectal balloon on rectal dosimetry during stereotactic body radiation therapy for localized prostate cancer
    Wong, Andrew T.
    Schreiber, David
    Agarwal, Manuj
    Polubarov, Aleksey
    Schwartz, David
    PRACTICAL RADIATION ONCOLOGY, 2016, 6 (04) : 262 - 267
  • [3] Evaluation of rectal balloon reproducibility for prostate radiation therapy using cone beam CT
    Ozawa, S.
    Lu, B.
    Song, W. Y.
    Kurokawa, C.
    Chvetsov, A.
    Palta, J. R.
    Liu, C.
    Karasawa, K.
    Li, J. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S560 - S560
  • [4] The impact of rectal/bladder filling and applicator positioning on in vivo rectal dosimetry in vaginal cuff brachytherapy using an enhanced therapy setting
    Bergau, Pia Franziska Luise
    Schirmer, Markus A.
    Leha, Andreas
    Leu, Martin
    Emons, Guenter
    Hess, Clemens F.
    Hille, Andrea
    BRACHYTHERAPY, 2020, 19 (02) : 168 - 175
  • [5] Phantom Analysis of Dental Filling Materials: Impact on Head and Neck Tumor Visualization and Proton Beam Dosimetry
    Richard, P.
    Sandison, G.
    Chapman, E.
    Dang, Q.
    Johnson, B.
    Wong, T.
    Parvathaneni, U.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S924 - S924
  • [6] Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer
    Kenji Takayama
    Takashi Mizowaki
    Yoshiharu Negoro
    Yoshiki Norihisa
    Masahiro Hiraoka
    International Journal of Clinical Oncology, 2011, 16 : 50 - 56
  • [7] Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer
    Takayama, Kenji
    Mizowaki, Takashi
    Negoro, Yoshiharu
    Norihisa, Yoshiki
    Hiraoka, Masahiro
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2011, 16 (01) : 50 - 56
  • [8] Rectal dose-volume differences for scanning proton beam therapy with or without an endorectal balloon for the treatment of prostate cancer
    Desai, Anand
    Stoker, Joshua B.
    Wages, Cody A.
    Zhu, X. Ron
    Lee, Andrew
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (06)
  • [9] Radiation dosimetry of organs and tissues at risk from 177Lu-DKFZ-PSMA-617 for prostate cancer therapy
    Hohberg, M.
    Eschner, W.
    Schmidt, M.
    Dietlein, M.
    Kobe, C.
    Fischer, T.
    Drzezga, A.
    Wild, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S414 - S415
  • [10] Intrafractional Motion of Target Volumes and Organs at Risk Due to Bladder Filling: Implications for MR-Only Prostate Radiation Therapy
    Sevak, P. R.
    Nejad-Davarani, S.
    Kim, J.
    Weiss, S.
    Elshaikh, M. A.
    Glide-Hurst, C. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E720 - E721