Effectiveness of Stack Ventilation in a Two-Storey House in Hot and Humid Climate

被引:0
|
作者
Chindavanig, Thanit [1 ]
机构
[1] Chulalongkorn Univ, Fac Architecture, Dept Architecture, Bangkok 10330, Thailand
关键词
D O I
10.1088/1757-899X/471/6/062008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objectives of this research were to design stack ventilation and to study its effectiveness in a two-storey house in hot and humid climate of Bangkok, Thailand Envelope openings at the rooftop and the entry door of the house were added to create height difference between inlet and outlet openings. Heat in the attic was utilized to make temperature difference in order to generate buoyancy for stack ventilation. The method of the study was experimentation in two existing houses, which had the same physical and had the most similar environment. The first house without stack ventilation was a base case. The second one was designed to integrate stack ventilation. Scientific instruments were installed in both houses at various positions. Air temperature, relative humidity and wind speed data were collected minutely for a few consecutive days for the evaluation of the experiment. It was founded that the house with stack ventilation had inside air temperature and relative humidity lower than those of the base case. The inside air temperature of the house with stack ventilation could be 0.7 Celsius lower than that of the base case. The relative humidity of the house with stack ventilation could have relative humidity of 12 % lower than that of the base case. Furthermore, the stack ventilation could make 1.06 air changes per hour with only 0.10% effective opening of building area having stack ventilation.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Developing the methodology to investigate the thermal comfort of hot-humid climate under different ventilation modes
    Chen, Po-Yuan
    Chan, Ying-Chieh
    CLIMATE RESILIENT CITIES - ENERGY EFFICIENCY & RENEWABLES IN THE DIGITAL ERA (CISBAT 2019), 2019, 1343
  • [32] Natural Ventilation Provisions in Terraced-House Designs in Hot-Humid Climates: Case of Putrajaya, Malaysia
    Ibiyeye, A. I.
    Mohd, F. Z. J.
    Zalina, S.
    PERTANIKA JOURNAL OF SOCIAL SCIENCE AND HUMANITIES, 2015, 23 (04): : 885 - 903
  • [33] Experimental and simulated energy performance of a personalized ventilation system with individual airflow control in a hot and humid climate
    Chen, Yixing
    Raphael, Benny
    Sekhar, S. C.
    BUILDING AND ENVIRONMENT, 2016, 96 : 283 - 292
  • [34] Assessment of natural ventilation strategies in historical buildings in a hot and humid climate using energy and CFD simulations
    Bay, Ezgi
    Martinez-Molina, Antonio
    Dupont, William A.
    JOURNAL OF BUILDING ENGINEERING, 2022, 51
  • [35] Applying the Passivhaus standard to a terraced house in a hot and humid tropical climate - Evaluation of comfort and energy performance
    Sigalingging, Roy Candra
    Chow, David
    Sharples, Steve
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2020, 41 (03): : 247 - 260
  • [36] Affordable retrofitting methods to achieve thermal comfort for a terrace house in Malaysia with a hot-humid climate
    Tuck, Ng Wai
    Zaki, Sheikh Ahmad
    Hagishima, Aya
    Rijal, Hom Bahadur
    Yakub, Fitri
    ENERGY AND BUILDINGS, 2020, 223
  • [37] Numerical assessment of the efficiency of fenestration system and natural ventilation mechanisms in a courtyard house in hot climate
    Wael A. Yousef Mousa
    Werner Lang
    Thomas Auer
    Building Simulation, 2017, 10 : 737 - 754
  • [38] Numerical assessment of the efficiency of fenestration system and natural ventilation mechanisms in a courtyard house in hot climate
    Mousa, Wael A. Yousef
    Lang, Werner
    Auer, Thomas
    BUILDING SIMULATION, 2017, 10 (05) : 737 - 754
  • [39] The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
    Kubota, Tetsu
    Chyee, Doris Toe Hooi
    Ahmad, Supian
    ENERGY AND BUILDINGS, 2009, 41 (08) : 829 - 839
  • [40] Increasing energy efficiency of displacement ventilation integrated with an evaporative-cooled ceiling for operation in hot humid climate
    Itani, Mariam
    Ghali, Kamel
    Ghaddar, Nesreen
    ENERGY AND BUILDINGS, 2015, 105 : 26 - 36