An implementation of time-efficient respiratory-gated PET acquisition by repeated breath-holds

被引:5
|
作者
Skretting, Arne [1 ,2 ]
Revheim, Mona-Elisabeth [2 ,3 ]
Knudtsen, Ingerid Skjei [4 ,5 ]
Johnsrud, Kjersti [3 ]
Bogsrud, Trond Velde [3 ]
机构
[1] Oslo Univ Hosp, Intervent Ctr, Oslo, Norway
[2] Univ Oslo, Inst Clin Med, Oslo, Norway
[3] Oslo Univ Hosp, Dept Radiol & Nucl Med, Oslo, Norway
[4] Univ Oslo, Dept Phys, Oslo, Norway
[5] Oslo Univ Hosp, Dept Med Phys, Oslo, Norway
关键词
Respiratory-gated PET; repeated breath-holds; PET/CT respiratory phase matching; lung; liver; MOTION; RECONSTRUCTION; CT;
D O I
10.1177/0284185113478007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Respiratory gating in positron emission tomography (PET) is used to improve detection of small tumors in the lower lung regions and in the liver, and to obtain a better estimate of the standardized uptake value (SUV). Purpose: To develop a time-efficient method for acquisition of respiratory-gated PET/CT that would produce one single high quality image volume corresponding to a breath-hold state. Material and Methods: An instrument was developed that displayed to the patient either red or green numbers, counting down from a chosen maximum to one at a rate of one dial per second. The patient was instructed to repeatedly hold the breath in moderate inspiration when red numbers were displayed and to breathe freely during display of green numbers. PET data were acquired in list mode and trigger signals were sent to the scanner and inserted into the list file each time the color of the countdown numbers switched from green to red. Data acquired during breath-holds were used to create one single image volume. Results: High quality breath-hold images were obtained from 10 min data acquisition at one bed position. Improved image quality compared to standard whole-body PET was demonstrated by a significant reduction of noise (standard deviation) in regions of normal liver tissues. Conclusion: The instruction to perform repeated breath-holds was well understood by patients and they cooperated satisfactorily. When the new procedure is used the duration of the data acquisition may typically be reduced by a factor of 4 compared to conventional respiratory-gated protocols where the patient breathes freely.
引用
收藏
页码:672 / 675
页数:4
相关论文
共 28 条
  • [21] High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation
    Forman, Christoph
    Piccini, Davide
    Grimm, Robert
    Hutter, Jana
    Hornegger, Joachim
    Zenge, Michael O.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (05) : 435 - 443
  • [22] Respiratory-gated FDG PET/CT versus PET/MRI with zero-echo time: Assessment of the capability to detect and differentiate lung lesions and the precision of fused images
    Inukai, J.
    Nogami, M.
    Zeng, F.
    Tachibana, M.
    Sakamoto, S.
    Takenaka, D.
    Kubo, K.
    Kurimoto, T.
    Murakami, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S166 - S167
  • [23] High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation
    Christoph Forman
    Davide Piccini
    Robert Grimm
    Jana Hutter
    Joachim Hornegger
    Michael O. Zenge
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 435 - 443
  • [24] Feasibility of a deep-inspiration breath-hold 18F-NOTA-LM3 PET/CT imaging in patients with upper-abdominal neuroendocrine tumors: in comparison with respiratory-gated PET/CT
    Zhang, Haiqiong
    Liu, Meixi
    Shi, Ximin
    Ma, Jiangyu
    Ren, Chao
    Huang, Zhenghai
    Wang, Ying
    Huo, Li
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [25] Whole-heart coronary MR angiography under a single breath-hold: A comparative study with respiratory-gated acquisition using a multi-element phased-array coil
    Okada, T.
    Kanao, S.
    Kuhara, S.
    Ninomiya, A.
    Fujimoto, K.
    Kido, A.
    Togashi, K.
    CLINICAL RADIOLOGY, 2011, 66 (11) : 1060 - 1063
  • [26] Respiratory-gated time-of-flight PET/CT during whole-body scan for lung lesions: feasibility in a routine clinical setting and quantitative analysis
    Naohisa Suzawa
    Yasutaka Ichikawa
    Masaki Ishida
    Yoya Tomita
    Ryohei Nakayama
    Hajime Sakuma
    Annals of Nuclear Medicine, 2016, 30 : 722 - 730
  • [27] Respiratory-gated time-of-flight PET/CT during whole-body scan for lung lesions: feasibility in a routine clinical setting and quantitative analysis
    Suzawa, Naohisa
    Ichikawa, Yasutaka
    Ishida, Masaki
    Tomita, Yoya
    Nakayama, Ryohei
    Sakuma, Hajime
    ANNALS OF NUCLEAR MEDICINE, 2016, 30 (10) : 722 - 730
  • [28] Feasibility of a deep-inspiration breath-hold [18F]AlF-NOTA-LM3 PET/CT imaging on upper-abdominal lesions in NET patients: in comparison with respiratory-gated PET/CT
    Zhang, Haiqiong
    Liu, Meixi
    Shi, Ximin
    Ma, Jiangyu
    Ren, Chao
    Huang, Zhenghai
    Wang, Ying
    Jing, Hongli
    Huo, Li
    EJNMMI PHYSICS, 2024, 11 (01):