An implementation of time-efficient respiratory-gated PET acquisition by repeated breath-holds

被引:5
|
作者
Skretting, Arne [1 ,2 ]
Revheim, Mona-Elisabeth [2 ,3 ]
Knudtsen, Ingerid Skjei [4 ,5 ]
Johnsrud, Kjersti [3 ]
Bogsrud, Trond Velde [3 ]
机构
[1] Oslo Univ Hosp, Intervent Ctr, Oslo, Norway
[2] Univ Oslo, Inst Clin Med, Oslo, Norway
[3] Oslo Univ Hosp, Dept Radiol & Nucl Med, Oslo, Norway
[4] Univ Oslo, Dept Phys, Oslo, Norway
[5] Oslo Univ Hosp, Dept Med Phys, Oslo, Norway
关键词
Respiratory-gated PET; repeated breath-holds; PET/CT respiratory phase matching; lung; liver; MOTION; RECONSTRUCTION; CT;
D O I
10.1177/0284185113478007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Respiratory gating in positron emission tomography (PET) is used to improve detection of small tumors in the lower lung regions and in the liver, and to obtain a better estimate of the standardized uptake value (SUV). Purpose: To develop a time-efficient method for acquisition of respiratory-gated PET/CT that would produce one single high quality image volume corresponding to a breath-hold state. Material and Methods: An instrument was developed that displayed to the patient either red or green numbers, counting down from a chosen maximum to one at a rate of one dial per second. The patient was instructed to repeatedly hold the breath in moderate inspiration when red numbers were displayed and to breathe freely during display of green numbers. PET data were acquired in list mode and trigger signals were sent to the scanner and inserted into the list file each time the color of the countdown numbers switched from green to red. Data acquired during breath-holds were used to create one single image volume. Results: High quality breath-hold images were obtained from 10 min data acquisition at one bed position. Improved image quality compared to standard whole-body PET was demonstrated by a significant reduction of noise (standard deviation) in regions of normal liver tissues. Conclusion: The instruction to perform repeated breath-holds was well understood by patients and they cooperated satisfactorily. When the new procedure is used the duration of the data acquisition may typically be reduced by a factor of 4 compared to conventional respiratory-gated protocols where the patient breathes freely.
引用
收藏
页码:672 / 675
页数:4
相关论文
共 28 条
  • [1] Reduction of respiratory effects on lung PET imaging with respiratory-gated acquisition associated with breath-hold CT
    Morvan, J.
    El Esper, I.
    Saidi, L.
    Moullart, V.
    Daouk, J.
    Fin, L.
    Bailly, P.
    Meyer, M. -E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (12): : 600 - 606
  • [2] Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
    Shozo Yamashita
    Kunihiko Yokoyama
    Masahisa Onoguchi
    Haruki Yamamoto
    Shigeaki Hiko
    Akihiro Horita
    Kenichi Nakajima
    Annals of Nuclear Medicine, 2014, 28 : 1 - 10
  • [3] Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
    Yamashita, Shozo
    Yokoyama, Kunihiko
    Onoguchi, Masahisa
    Yamamoto, Haruki
    Hiko, Shigeaki
    Horita, Akihiro
    Nakajima, Kenichi
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 1 - 10
  • [4] Benefits of respiratory-gated 18F-FDG PET acquisition in lung disease
    Bailly, Pascal
    Bouzerar, Roger
    Shields, Trevor
    Meyer, Marc-Etienne
    Daouk, Joel
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (01) : 44 - 50
  • [5] Respiratory-gated PET imaging with reduced acquisition time for suspect malignancies: the first experience in application of total-body PET/CT
    Liu, Guobing
    Chen, Shuguang
    Hu, Yan
    Cao, Shuangliang
    Yang, Xinlan
    Zhou, Yun
    Shi, Hongcheng
    EUROPEAN RADIOLOGY, 2023, 33 (05) : 3366 - 3376
  • [6] Respiratory-gated PET imaging with reduced acquisition time for suspect malignancies: the first experience in application of total-body PET/CT
    Guobing Liu
    Shuguang Chen
    Yan Hu
    Shuangliang Cao
    Xinlan Yang
    Yun Zhou
    Hongcheng Shi
    European Radiology, 2023, 33 : 3366 - 3376
  • [7] Impact of a respiratory-gated 18FDG PET-CT acquisition for the liver lesions diagnosis
    Collet, G.
    Breviere, Y.
    Baillet, C.
    Devos, L.
    Vermandel, M.
    Huglo, D.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2016, 40 (02): : 84 - 91
  • [8] Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions
    Fin, Loic
    Daouk, Joeel
    Morvan, Julie
    Bailly, Pascal
    El Esper, Isabelle
    Saidi, Lazhar
    Meyer, Marc-Etienne
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (11) : 1971 - 1980
  • [9] Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions
    Loïc Fin
    Joël Daouk
    Julie Morvan
    Pascal Bailly
    Isabelle El Esper
    Lazhar Saidi
    Marc-Etienne Meyer
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 1971 - 1980
  • [10] Respiratory-gated and deep inspiration breath-hold FDG PET/CT protocols for evaluation of pulmonary and abdominal lesions
    Aga, Fumitoshi
    Yamamoto, Yuka
    Maeda, Yukito
    Takahashi, Yousuke
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53