Frequency, duration, magnitude, and consequences of myocardial ischemia during intracoronary ultrasonography

被引:3
|
作者
Drew, BJ
Adams, MG
McEldowney, DK
Lau, KY
Wung, SF
Wolfe, CL
Ports, TA
Chou, TM
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT MED,DIV CARDIOL,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,INST CARDIOVASC RES,SAN FRANCISCO,CA 94143
关键词
D O I
10.1016/S0002-8703(97)70084-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the Frequency, duration, magnitude, and possible adverse effects of ischemia during intracoronary ultrasonography, real-time standard 12-lead electrocardiograms were recorded before, during, and after ultrasonography. Ischemia was defined as new-onset ST segment deviation of greater than or equal to 1 mm in one or more leads, measured at J + 80 msec. The magnitude of ischemia was expressed as the sum of absolute ST segment deviations across 12 leads. Eighteen (67%) of 27 patients had ischemia during intracoronary ultrasonography. The electrocardiogram resembled the characteristic pattern observed with occlusion of the vessel under study, involving ST segment elevation in contiguous leads in 89% of patients. A higher proportion of women (88%) had ischemia than men (58%), and women had smaller arterial lumenal areas compared with men (6.3 vs 9.1 mm(2); p < 0.05). Individuals with ischemia were smaller than those without ischemia (body surface area = 1.99 vs 1.79 m(2); P = 0.01). The mean duration of ischemia was 4 minutes and the mean 12-lead ST segment deviation score was 8.5 mm (maximum 20.5 mm). No patient with ischemia during ultrasonography had complications. Ischemia is common during intracoronary ultrasonography, particularly in women and individuals with smaller vessels; however, no adverse outcomes occur as a result.
引用
收藏
页码:474 / 478
页数:5
相关论文
共 50 条
  • [21] Accuracy of intracoronary ECG parameters for myocardial ischemia detection
    Bigler, Marius Reto
    Zimmermann, Patrick
    Papadis, Athanasios
    Seiler, Christian
    JOURNAL OF ELECTROCARDIOLOGY, 2021, 64 : 50 - 57
  • [22] INTRACORONARY BALLOON - NEW MODEL FOR INDUCTION OF MYOCARDIAL ISCHEMIA
    CORDAY, E
    CREXELLS, C
    MEERBAUM, S
    LANG, TW
    AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02): : 301 - &
  • [23] VALUE OF INTRACORONARY VENOUS ELECTROCARDIOGRAM TO DETECT REGIONAL MYOCARDIAL-ISCHEMIA DURING INTRACORONARY INJECTION OF ACETYLCHOLINE - COMPARISON WITH LACTATE METABOLISM
    ADACHI, T
    HIRAYAMA, A
    SAKAI, A
    MISAKI, N
    HASEGAWA, S
    UEDA, Y
    KODAMA, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A374 - A374
  • [24] USEFULNESS OF INTRACORONARY ISOSORBIDE DINITRATE IN ALLEVIATING MYOCARDIAL-ISCHEMIA DURING CORONARY BALLOON ANGIOPLASTY
    LEWIS, BS
    HALON, DA
    MERDLER, A
    MAKHOUL, N
    AFRIAT, S
    SCHNEEWEISS, A
    EUROPEAN HEART JOURNAL, 1992, 13 (11) : 1534 - 1539
  • [25] Frequency of chest pain during myocardial ischemia: Is there a gender difference?
    Adams, MG
    Pelter, MM
    Chang, TWH
    Wung, SF
    Drew, BJ
    CIRCULATION, 1997, 96 (08) : 743 - 743
  • [26] ACUTE MYOCARDIAL ISCHEMIA - CELLULAR CONSEQUENCES
    不详
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1983, 125 (50): : A44 - A44
  • [27] THE EARLY CONSEQUENCES OF MYOCARDIAL ISCHEMIA AND THEIR MODIFICATION
    MARSHALL, RJ
    PARRATT, JR
    JOURNAL DE PHYSIOLOGIE, 1980, 76 (07): : 699 - 715
  • [28] EFFECT OF DURATION OF REGIONAL MYOCARDIAL ISCHEMIA AND DEGREE OF REACTIVE HYPEREMIA ON THE MAGNITUDE OF THE INITIAL TL-201 DEFECT
    WHARTON, TP
    NEILL, WA
    OXENDINE, JM
    PAINTER, LN
    CIRCULATION, 1980, 62 (03) : 516 - 521
  • [29] EFFECTS OF DURATION AND DEGREE OF MYOCARDIAL ISCHEMIA ON ARRHYTHMIAS AND CELLULAR ELECTROPHYSIOLOGY DURING REPERFUSION
    PENNY, W
    SHERIDAN, D
    CIRCULATION, 1982, 66 (04) : 157 - 157
  • [30] THE EFFECT OF SEVERITY AND DURATION OF MYOCARDIAL ISCHEMIA ON ELECTROPHYSIOLOGY AND ARRHYTHMIAS DURING SUBSEQUENT REPERFUSION
    PENNY, WJ
    SHERIDAN, DJ
    CLINICAL SCIENCE, 1982, 63 (03) : P48 - P48