For the problem of incapable to determine the width of spherical diffuser, four groups of spherial diffusers with different width were designed by using the speed coefficient method. Numerical investigation of internal flow in the nuclear coolant pumps with these diffusers was made based on ANSYS-CFX software. Aimed at the efficiency, ditribution of pressure and velocity vector on the meridian plane of each volute scheme was analysised emphatically. By comparing the performance curves of the coolant pumps predicted by the numerical simulation, we can draw that the head and efficiency of pump decreased as the increasing of diffuser width and performanced worst at the width of d=1.7R, then the performance no longer changes when diffuser width continue to reduce.
引用
收藏
页码:921 / 925
页数:5
相关论文
共 50 条
  • [1] Optimization design and test research of AP1000 nuclear reactor coolant pump
    Fu, Qiang
    Xi, Yi
    Zhu, Rong-Sheng
    Wang, Xiu-Li
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (09): : 1648 - 1654
  • [2] Evaluation of service reliability of AP1000 nuclear reactor coolant pump rotor-can
    Cui, Yan
    Zhang, Chi
    Zhang, Liwen
    Song, Kangjie
    ANNALS OF NUCLEAR ENERGY, 2022, 172
  • [3] Root Cause Analysis of In-Situ AP1000 Reactor Coolant Pump Lock Cup Failure
    Fan F.
    Lu Z.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (04): : 176 - 181
  • [4] Reliability analysis of the precision assembly process of a scaled stator can of the AP1000 reactor coolant pump
    Jiang, Wei
    Liu, Huahan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2019, 233 (05) : 1504 - 1519
  • [5] Analysis on NDE problem of weld joint between AP1000 steam generator and reactor coolant pump casing
    Mao, Chang-Sen
    Chen, Fu-Bin
    Hedongli Gongcheng/Nuclear Power Engineering, 2013, 34 (06): : 143 - 147
  • [6] Simulation of the AP1000 reactor containment pressurization during loss of coolant accident
    Rahim, Farzad Choobdar
    Yousefi, Pooria
    Aliakbari, Elnaz
    PROGRESS IN NUCLEAR ENERGY, 2012, 60 : 129 - 134
  • [7] Development of In-Service Inspection System for Flange Bolts of Reactor Coolant Pump in AP1000 Nuclear Power Plant
    Zhou L.
    Wang L.
    Liu Y.
    Chen J.
    Hedongli Gongcheng/Nuclear Power Engineering, 2022, 43 (04): : 162 - 167
  • [8] Study on Transient Performance in Loss of Coolant Accident for AP1000 SFP
    Duan Y.
    He X.
    Jing F.
    Cai Z.
    Yu X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (01): : 147 - 151
  • [9] Study of impact of the AP1000® reactor vessel upper internals design on fuel performance
    Xu, Yiban
    Conner, Michael
    Yuan, Kun
    Dzodzo, Milorad B.
    Karoutas, Zeses
    Beltz, Steven A.
    Ray, Sumit
    Bissett, Teresa A.
    Chieng, Ching-Chang
    Kao, Min-Tsung
    Wu, Chung-Yun
    NUCLEAR ENGINEERING AND DESIGN, 2012, 252 : 128 - 134
  • [10] Major Milestones for the AP1000 Reactor
    不详
    POWER, 2011, 155 (02) : 8 - 8