Study of impact of the AP1000® reactor vessel upper internals design on fuel performance

被引:9
|
作者
Xu, Yiban [2 ]
Conner, Michael [2 ]
Yuan, Kun [2 ]
Dzodzo, Milorad B. [2 ]
Karoutas, Zeses [2 ]
Beltz, Steven A. [2 ]
Ray, Sumit [2 ]
Bissett, Teresa A. [2 ]
Chieng, Ching-Chang [1 ]
Kao, Min-Tsung [1 ]
Wu, Chung-Yun [1 ]
机构
[1] Natl Tsing Hua Univ, Hsinchu 30043, Taiwan
[2] Westinghouse Elect Co, Cranberry Township, PA 16066 USA
关键词
BOUNDARY;
D O I
10.1016/j.nucengdes.2012.06.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
One aspect of the AP1000((R) 1) reactor design is the reduction in the number of major components and simplification in manufacturing. One design change relative to current Westinghouse reactors of similar size is the reduction in the number of reactor vessel outlet nozzles/hot legs leaving the upper plenum from three to two. With regard to fuel performance, this design difference creates a different flow field in the AP1000 reactor vessel upper plenum (the region above the core). The flow exiting core and entering the upper plenum must turn 90 degrees, flow laterally through the upper plenum around support structures, and exit through one of the two outlet nozzles. While the flow in the top of the core is mostly axial, there is some lateral flow component as the core flow reacts to the flow field and pressure distribution in the upper plenum. The pressure distribution in the upper plenum varies laterally depending upon various factors including the proximity to the outlet nozzles. To determine how the lateral flow in the top of the AP1000 core compares to current Westinghouse reactors, a computational fluid dynamics (CFD) model of the flow in the upper portion of the AP1000 reactor vessel including the top region of the core, the upper plenum, the reactor vessel outlet nozzles, and a portion of the hot legs was created. Due to geometric symmetry, the computational domain was reduced to a quarter (from the top view) that includes 1/4 of the top of the core, 1/4 of the upper plenum, and 1/2 of an outlet nozzle. Results from this model include predicted velocity fields and pressure distributions throughout the model domain. The flow patterns inside and around guide tubes clearly demonstrate the influence of lateral flow due to the presence of the outlet nozzles. From these results, comparisons of AP1000 flow versus current Westinghouse plants were performed. Field performance information from current Westinghouse plants will be shown to demonstrate an experience base of acceptable core lateral flows. From this experience base and the AP1000 CFD results, acceptability of the AP1000 upper plenum design on the fuel performance of the AP1000 fuel design will be demonstrated. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [1] Impact Of Diffuser Width On The Performance Of AP1000 Reactor Coolant Pump
    Yuan, Danqing
    Yan, Hua
    Wang, Peipei
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 921 - 925
  • [2] AP1000 FUEL DESIGN AND CORE OPERATIONS
    Miller, R. Wade
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 1, 2008, : 297 - 304
  • [3] The AP1000™ Reactor: Passive Safety and Modular Design
    Sutharshan, Balendra
    Mutyala, Meena
    Vijuk, Ronald P.
    Mishra, Alok
    ASIAN NUCLEAR PROSPECTS 2010, 2011, 7 : 293 - 302
  • [4] Study of the Reactor Control System of MSHIM in AP1000
    Wei, Xinyu
    Zhao, Fuyu
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2015, 2015
  • [5] Preliminary Study of Plutonium Utilization in AP1000 Reactor
    Nailatussaadah
    Prastyo, Puguh A.
    Waris, Abdul
    Kurniadi, Rizal
    Pramuditya, Syeilendra
    INTERNATIONAL CONFERENCE ON ENERGY SCIENCES (ICES 2016), 2017, 877
  • [6] Major Milestones for the AP1000 Reactor
    不详
    POWER, 2011, 155 (02) : 8 - 8
  • [7] Experimental study of upper plenum entrainment in AP1000
    Xiang Y.
    Sun D.-C.
    Wu Y.-W.
    Zhang P.
    Qiu S.-Z.
    Su G.-H.
    2016, Atomic Energy Press (50): : 61 - 65
  • [8] Calculation and analysis of fast neutron fluence of pressure vessel in AP1000 reactor
    Wang, Yue
    Quan, Guoping
    Yee, Yeoh Eing
    Zhu, Cheng-lin
    Yu, Hui
    JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, SNA + MC 2024, 2024, 302
  • [9] The effects of thermal stress on the crack propagation in AP1000 reactor pressure vessel
    Liu, KaiTai
    Huang, Mei
    Lin, JunJie
    Jiang, HaiPeng
    Wang, BoXue
    Matsuda, Hiroshi
    THEORETICAL AND APPLIED FRACTURE MECHANICS, 2020, 110
  • [10] AP1000 Design Certification
    不详
    NUCLEAR PLANT JOURNAL, 2006, 24 (01) : 14 - 14