Design of ITER divertor VUV spectrometer and prototype test at KSTAR tokamak

被引:9
|
作者
Seon, Changrae [1 ]
Hong, Joohwan [2 ]
Song, Inwoo [2 ]
Jang, Juhyeok [2 ]
Lee, Hyeonyong [2 ]
An, Younghwa [1 ]
Kim, Bosung [3 ]
Jeon, Taemin [2 ]
Park, Jaesun [2 ]
Choe, Wonho [2 ]
Lee, Hyeongon [1 ]
Pak, Sunil [1 ]
Cheon, MunSeong [1 ]
Choi, Jihyeon [1 ]
Kim, Hyeonseok [1 ]
Biel, Wolfgang [4 ]
Bernascolle, Philippe [5 ]
Barnsley, Robin [5 ]
O'Mullane, Martin [6 ]
机构
[1] Natl Fus Res Inst, Gwahangno 169-148, Daejeon, South Korea
[2] Korea Adv Inst Sci & Technol, Daehak Ro,291, Daejeon, South Korea
[3] Ajou Univ, Dept Energy Syst Res, Suwon 443749, South Korea
[4] Forschungszentrum Julich, EURATOM Assoc, Trilateral Euregio Cluster, Inst Plasmaphys, D-52425 Julich, Germany
[5] ITER Org, Route Vinon Sur Verdon CS 90 046, St Paul Les Durance, France
[6] Univ Strathclyde, Dept Phys SUPA, Glasgow G4 ONG, Lanark, Scotland
来源
EUROPEAN PHYSICAL JOURNAL D | 2017年 / 71卷 / 12期
基金
新加坡国家研究基金会;
关键词
VACUUM-ULTRAVIOLET; X-RAY; SPECTROSCOPY; RESOLUTION; DETECTOR; RANGE;
D O I
10.1140/epjd/e2017-70825-3
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Design and development of the ITER divertor VUV spectrometer have been performed from the year 1998, and it is planned to be installed in the year 2027. Currently, the design of the ITER divertor VUV spectrometer is in the phase of detail design. It is optimized for monitoring of chord-integrated VUV signals from divertor plasmas, chosen to contain representative lines emission from the tungsten as the divertor material, and other impurities. Impurity emission from overall divertor plasmas is collimated through the relay optics onto the entrance slit of a VUV spectrometer with working wavelength range of 14.6-32 nm. To validate the design of the ITER divertor VUV spectrometer, two sets of VUV spectrometers have been developed and tested at KSTAR tokamak. One set of spectrometer without the field mirror employs a survey spectrometer with the wavelength ranging from 14.6nm to 32nm, and it provides the same optical specification as the spectrometer part of the ITER divertor VUV spectrometer system. The other spectrometer with the wavelength range of 5-25nm consists of a commercial spectrometer with a concave grating, and the relay mirrors with the same geometry as the relay mirrors of the ITER divertor VUV spectrometer. From test of these prototypes, alignment method using backward laser illumination could be verified. To validate the feasibility of tungsten emission measurement, furthermore, the tungsten powder was injected in KSTAR plasmas, and the preliminary result could be obtained successfully with regard to the evaluation of photon throughput.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Data acquisition and monitoring system for KSTAR VUV spectrometer systems
    An, YoungHwa
    Kim, Boseong
    Shin, Haewon
    Kim, Yeonjung
    Seon, Changrae
    Song, Inwoo
    Cheon, MunSeong
    FUSION ENGINEERING AND DESIGN, 2022, 175
  • [22] Design, analysis and test concept for prototype cryoline of ITER
    Sarkar, B.
    Badgujar, S.
    Vaghela, H.
    Shah, N.
    Bhattachary, R.
    Chakrapani, Ch.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1716 - 1723
  • [23] Prototype Design and Test of ITER PF Converter Unit
    Song, Zhiquan
    Fu, Peng
    Li, Jinchao
    Wang, Peng
    Zhang, Xiuqing
    Li, Chuan
    Yang, Yong
    Dong, Ling
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (09) : 1677 - 1683
  • [24] Divertor Tokamak Test facility project: status of design and implementation
    Romanelli, Francesco
    Abate, D.
    Acampora, E.
    Agguiaro, D.
    Agnello, R.
    Agostinetti, P.
    Agostini, M.
    Aimetta, A.
    Albanese, R.
    Alberti, G.
    Albino, M.
    Alessi, E.
    Almaviva, S.
    Alonzo, M.
    Ambrosino, R.
    Andreoli, P.
    Angelone, M.
    Angelucci, M.
    Angioni, C.
    Armenio, A. Angrisani
    Antonini, P.
    Aprile, D.
    Apruzzese, G.
    Aquilini, M.
    Aragone, G.
    Arena, P.
    Ariola, M.
    Artaserse, G.
    Aucone, L.
    Augieri, A.
    Auriemma, F.
    Ayllon Guerola, J.
    Badodi, N.
    Baiocchi, B.
    Balbinot, L.
    Baldacchini, C.
    Balestri, A.
    Barberis, T.
    Barone, G.
    Barucca, L.
    Baruzzo, M.
    Begozzi, S.
    Belardi, V.
    Belli, F.
    Belpane, A.
    Beone, F.
    Bertolami, S.
    Bianucci, S.
    Bifaretti, S.
    Bigioni, S.
    NUCLEAR FUSION, 2024, 64 (11)
  • [25] A prototype of the centrifugal pellet injector for the ITER tokamak
    Vinyar, I. V.
    Lukin, A. Ya.
    Skoblikov, S. V.
    Umov, A. P.
    Reznichenko, P. V.
    Krasil'nikov, I. A.
    Panchenko, V. I.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (04) : 577 - 584
  • [26] A prototype of the centrifugal pellet injector for the ITER tokamak
    I. V. Vinyar
    A. Ya. Lukin
    S. V. Skoblikov
    A. P. Umov
    P. V. Reznichenko
    I. A. Krasil’nikov
    V. I. Panchenko
    Instruments and Experimental Techniques, 2006, 49 : 577 - 584
  • [27] Optics design of the divertor infrared television of KSTAR
    Oh, S.
    Lee, K.
    Lee, H. H.
    Wi, H. M.
    Kim, Y. S.
    Kang, C. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [28] Edge plasma analyses for KSTAR divertor design
    Im, KH
    Han, JH
    Hill, DN
    Braams, B
    Fenstermacher, M
    Kim, J
    Lee, BJ
    Lee, GS
    Park, HK
    17TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, VOLS 1 AND 2, 1998, : 756 - 759
  • [29] Requirements and interface management for the divertor system design and integration in the Divertor Tokamak Test (DTT) facility
    Tenaglia, Giovanni
    Romanelli, Francesco
    La Rovere, Stefano
    Polli, Gian Mario
    Roccella, Selanna
    Ramogida, Giuseppe
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [30] Design study and preliminary feasibility analysis of divertor with ITER-Like PFU for advanced tokamak
    Peng, Xuebing
    Mao, Xin
    Liu, Peng
    Yang, Lei
    Qian, Xinyuan
    Song, Wei
    FUSION ENGINEERING AND DESIGN, 2021, 164