Robust Gradient-Based 3-D/2-D Registration of CT and MR to X-Ray Images

被引:67
|
作者
Markelj, Primoz [1 ]
Tomazevic, Dejan [1 ,2 ]
Pernus, Franjo [1 ]
Likar, Bostjan [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
[2] Sensum, Comp Vis Syst, Ljubljana 1000, Slovenia
关键词
Image-guided; intensity gradients; intervention; surgery; three-dimensional/two-dimensional (3-D/2-D) registration;
D O I
10.1109/TMI.2008.923984
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
One of the most important technical challenges in image-guided intervention is to obtain a precise transformation between the intrainterventional patient's anatomy and corresponding preinterventional 3-D image on which the intervention was planned. This goal can be achieved by acquiring intrainterventional 2-D images and matching them to the preinterventional 3-D image via 3-D/2-D image registration. A novel 3-D/2-D registration method is proposed in this paper. The method is based on robustly matching 3-D preinterventional image gradients and coarsely reconstructed 3-D gradients from the intrainterventional 2-D images. To improve the robustness of finding the correspondences between the two sets of gradients, hypothetical correspondences are searched for along normals to anatomical structures in 3-D images, while the final correspondences are established in an iterative process, combining the robust random sample consensus algorithm (RANSAC) and a special gradient matching criterion function. The proposed method was evaluated using the publicly available standardized evaluation methodology for 3-D/2-D registration, consisting of 3-D rotational X-ray, computed tomography, magnetic resonance (MR), and 2-D X-ray images of two spine segments, and standardized evaluation criteria. In this way, the proposed method could be objectively compared to the intensity, gradient, and reconstruction-based registration methods. The obtained results indicate that the proposed method performs favorably both in terms of registration accuracy and robustness The method is especially superior when just a few X-ray image, and when MR preinterventional images are used for registration, which are important advantages for many clinical applications.
引用
收藏
页码:1704 / 1714
页数:11
相关论文
共 50 条
  • [41] Automated Registration of CT and MR brain images using 3-D edge detection
    Hsu, LY
    Loew, MH
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 679 - 682
  • [42] CAN X-RAY PHOTOMETRY BE APPLIED TO 3-D IMAGES
    NEWBERRY, SP
    ZOOLOGICAL STUDIES, 1995, 34 : 249 - 250
  • [43] Direct recording and reconstruction of 3-D x-ray images
    Hamasaki, J.
    Yokota, K.
    Applied Optics, 1978, 17 (19) : 3125 - 3132
  • [44] Fast 2D-3D marker-based registration of CT and X-ray fluoroscopy images for image-guided surgery
    Hong, Helen
    Kim, Kyehyun
    Park, Sungjin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [45] 3-D DISPLAY OF X-RAY IMAGES BY MEANS OF HOLOGRAPHY
    GROH, G
    KOCK, M
    APPLIED OPTICS, 1970, 9 (03): : 775 - &
  • [46] DIRECT RECORDING AND RECONSTRUCTION OF 3-D X-RAY IMAGES
    HAMASAKI, J
    YOKOTA, K
    APPLIED OPTICS, 1978, 17 (19): : 3125 - 3132
  • [47] 2-D registration and 3-D shape inference of the retinal fundus from fluorescein images
    Choe, Tae Eun
    Medioni, Gerard
    Cohen, Isaac
    Walsh, Alexander C.
    Sadda, SriniVas R.
    MEDICAL IMAGE ANALYSIS, 2008, 12 (02) : 174 - 190
  • [48] 2-D MR Spectroscopy Combined with 2-D/3-D Spatial Encoding
    Thomas, M. Albert
    Iqbal, Zohaib
    Sarma, Manoj K.
    Nagarajan, Rajakumar
    Macey, Paul M.
    Huda, Amir
    EMAGRES, 2016, 5 (01): : 1039 - 1060
  • [49] 2-D/3-D Image Registration of Implanted Knee DR Images with Kalman Filter
    Nakajima, Yusuke
    Kobashi, Syoji
    Tsumori, Yohei
    Shimanuma, Nao
    Imawaki, Seturo
    Yoshiya, Shinichi
    Hata, Yutaka
    2009 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC 2009), VOLS 1-9, 2009, : 1107 - +
  • [50] Matching 3-D models to 2-D images
    Jacobs, DW
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 21 (1-2) : 123 - 153