Addition of an Anti-rotation Screw to the Dynamic Hip Screw for Femoral Neck Fractures

被引:25
|
作者
Makki, Daoud [1 ]
Mohamed, Ahmed M. [1 ]
Gadiyar, Rajeev [1 ]
Patterson, Marc [1 ]
机构
[1] Brighton & Univ Hosp NHS Trust, Royal Sussex Cty Hosp, Dept Trauma & Orthopaed, Brighton BN2 5BE, E Sussex, England
关键词
INTRACAPSULAR FRACTURES; FIXATION;
D O I
10.3928/01477447-20130624-15
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The authors investigated the use of an anti-rotation screw with the dynamic hip screw (DHS) during internal fixation of Garden I and II femoral neck fractures. Sixty-five patients with Garden I and II femoral neck fractures (mean age, 70 years) were treated with internal fixation at the authors' institution. In 31 patients, a 2-hole DHS was used alone (group 1), and in 34 patients, the DHS was combined with an anti-rotation screw placed in the cranial part of femoral head and neck (group 2). Patients' preinjury function and mental level were assessed using the Barthel index and the Abbreviated Mental test, respectively. The outcome measures included cost implications, operative time, and intraoperative radiation dose. The modified Harris Hip Score and a radiological assessment were performed at a mean of 11 months (range, 8-24 months) postoperatively. The use of the anti-rotation screw was associated with a longer operative time (mean, 44.54 minutes in group 1 vs 51.52 minutes in group 2; P<.0001) and more fluoroscopy screening (mean dose area product, 28.39 cGy/cm(2) in group 1 vs 44.33 cGy/cm(2) in group 2; P=.03). The additional cost of using an anti-rotation screw was 106 pound ($170) per case. No difference existed between the 2 groups with regard to radiological union, onset of avascular necrosis, and rate of revision surgeries. An anti-rotation screw, used with the dynamic hip screw, involves extra costs, prolongs operative time, and requires more intraoperative fluoroscopy screening but offers no advantages with regard to fracture union.
引用
收藏
页码:E865 / E868
页数:4
相关论文
共 50 条
  • [31] Fixed angle device comparison in young femoral neck fractures: Dynamic hip screw vs dynamic helical hip system
    Marchand, Lucas S.
    Butler, Bennet
    McKegg, Phillip
    DeLeon, Genaro
    O'Hara, Nathan N.
    Lebrun, Christopher T.
    Sciadini, Marcus F.
    Nascone, Jason W.
    O'Toole, Robert, V
    Slobogean, Gerard M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 590 - 595
  • [32] Dynamic Hip Screw Osteosynthesis for Proximal Femoral Fractures in Patients with Coxarthrosis
    Hrubina, M.
    Skotak, M.
    Letocha, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2015, 82 (05) : 364 - 368
  • [33] Effect of dynamic hip screw on the treatment of femoral neck fracture in the elderly
    Zhao Wenbo
    Liu Lei
    Zhang Hui
    Fang Yue
    Pei Fuxing
    Yang Tianfu
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (02) : 69 - 72
  • [34] FOLLOW-UP EXAMINATIONS IN OSTEOSYNTHESIS OF SUBCAPITAL FEMORAL-NECK FRACTURES WITH A DYNAMIC HIP SCREW
    PETERHANS, M
    VONFLUE, M
    HILDELL, J
    VOGT, B
    HELVETICA CHIRURGICA ACTA, 1991, 57 (05) : 815 - 819
  • [35] Intertrochanteric osteotomy using a dynamic hip screw for femoral neck nonunion
    Hartford, JM
    Patel, A
    Powell, J
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (05) : 329 - 333
  • [36] Effect of dynamic hip screw on the treatment of femoral neck fracture in the elderly
    Zhao Wenbo
    Liu Lei
    Zhang Hui
    Fang Yue
    Pei Fuxing
    Yang Tianfu
    中华创伤杂志(英文版), 2014, 17 (02) : 69 - 72
  • [37] COMPRESSION HIP SCREW VERSUS VONBAHR SCREWS IN FEMORAL-NECK FRACTURES
    LANGELAND, N
    ENGESAETER, LB
    ASSERSON, O
    MOLSTER, A
    GJERDET, NR
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 687 - 688
  • [38] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [39] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [40] Biomechanical comparison of femoral neck anti-rotation and support system versus femoral neck system for unstable pauwels III femoral neck fractures
    Wang, Taiyou
    Wang, Guangjian
    Zhu, Fukang
    Qiao, Bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):