Manual aspiration in the biopsy-side down position to deal with delayed pneumothorax after lung biopsy

被引:4
|
作者
Zeng, Li-Chuan [1 ]
Yang, Han-Feng [2 ]
Xu, Xiao-Xue [2 ]
Xie, Ming-Guo [1 ]
Liao, Hua-Qiang [1 ]
Zhang, Yu-Dong [1 ]
Wang, Qu [3 ]
Du, Yong [2 ]
机构
[1] Chengdu Univ Tradit Chinese Med, Sch Clin Med, Chengdu 610075, Sichuan, Peoples R China
[2] Affiliated Hosp North Sichuan Med Coll, Dept Radiol, 63 Wenhua Rd, Nanchong 637000, Peoples R China
[3] Chengdu Univ Tradit Chinese Med, Teaching Hosp, Dept Ultrasound, Chengdu 610072, Sichuan, Peoples R China
关键词
Aspiration; lung biopsy; pneumothorax; TRANSTHORACIC NEEDLE-BIOPSY; COMPLICATIONS; LESIONS; TRACK; RISK;
D O I
10.21037/jtd.2017.12.03
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: To assess the effect of aspiration in the biopsy-side down position to deal with delayed pneumothorax after computed tomography (CT)-guided lung biopsy. Methods: A retrospective review was performed of the 236 delayed pneumothorax patients who underwent CT-guided transthoracic needle biopsies (TTNBs). Asymptomatic minimal pneumothorax patients were managed conservatively. Manual aspirations were applied for symptomatic cases with minimal pneumothorax and all cases with moderate to large pneumothorax. Patients were included into two groups: in group A (35 patients), aspiration was performed in the same position as the biopsy, while in group B (54 patients), patients were turned to the biopsy-side down position (from supine to prone or vice versa), and aspiration was conducted. The efficacy of two approaches was evaluated. Results: One hundred forty-seven (62.3%) asymptomatic cases resolved without treatment. Distance between parietal and visceral pleura before and after aspiration were 4.24 +/- 1.87 and 1.93 +/- 2.33 cm for group A, 3.92 +/- 1.31 and 0.98 +/- 1.50 cm for group B, respectively. Volume of aspirated air in group A and group B were 735.4 +/- 231.8 and 434.8 +/- 320.3 mL, respectively. Complete lung expansion was detected in 28.6% (1035) and 38.9% (2154) for group A and group B, respectively. The overall effective rate and failure rate were 74.3% (2635) and 25.7%(935) for group A, 92.6% (5054) and 7.4%((454)) for group B, respectively, which have significant statistic difference (P<0.05). Conclusions: Manual aspiration in biopsy-side down position demonstrates the safety and efficacy in treating delayed pneumothorax after CT-guided TTNBs. Thus reduce the rate of pneumothorax requiring drainage catheter placement.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 50 条
  • [21] Pneumothorax after transbronchial biopsy or fine needle aspiration: can it be predicted?
    Zink, A.
    Fritsch, K.
    Eich, C.
    Thurnheer, R.
    SWISS MEDICAL WEEKLY, 2007, 137 : 22S - 22S
  • [22] DIAGNOSIS OF PNEUMOTHORAX BY ULTRASOUND IMMEDIATELY AFTER ULTRASONICALLY GUIDED ASPIRATION BIOPSY
    TARGHETTA, R
    BOURGEOIS, JM
    CHAVAGNEUX, R
    BALMES, P
    CHEST, 1992, 101 (03) : 855 - 856
  • [23] Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    Kazerooni, EA
    Lim, FT
    Mikhail, A
    Martinez, FJ
    RADIOLOGY, 1996, 198 (02) : 371 - 375
  • [24] Patient positioning after lung biopsy: influence on the incidence of pneumothorax
    Masterson, AV
    Haslam, P
    Logan, PM
    Lee, MJ
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2003, 54 (01): : 31 - 34
  • [25] CT-guided lung biopsy:: incidence of pneumothorax after instillation of NaCl into the biopsy track
    Billich, Christian
    Muche, Rainer
    Brenner, Gerhard
    Schmidt, Stefan A.
    Krueger, Stefan
    Brambs, Hans-Juergen
    Pauls, Sandra
    EUROPEAN RADIOLOGY, 2008, 18 (06) : 1146 - 1152
  • [26] CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track
    Christian Billich
    Rainer Muche
    Gerhard Brenner
    Stefan A. Schmidt
    Stefan Krüger
    Hans-Jürgen Brambs
    Sandra Pauls
    European Radiology, 2008, 18 : 1146 - 1152
  • [27] Pneumothorax after CT-guided transthoracic lung biopsy: A comparison between immediate and delayed occurrence
    Bae, Kyungsoo
    Ha, Ji Young
    Jeon, Kyung Nyeo
    PLOS ONE, 2020, 15 (08):
  • [28] Early detection of delayed pneumothorax using lung ultrasound after transthoracic needle lung biopsy: A prospective pilot study
    Koh, Jeong Suk
    Chung, Chaeuk
    Kim, Ju Ock
    Jung, Sung Soo
    Park, Hee Sun
    Lee, Jeong Eun
    Kang, Da Hyun
    Kim, Yoonjoo
    Park, Dongil
    CLINICAL RESPIRATORY JOURNAL, 2022, 16 (05): : 413 - 419
  • [29] Effect of Size of the Lesion on the Rate of Pneumothorax after CT Guided Transthoracic Needle Aspiration Biopsy of Lung Masses
    Shaukat, Asim
    Amin, Yasser
    Khan, Tahir Qadeer
    Qureshi, Afshan
    Khurshid, Khawaja
    Anjum, Muhammad Nawaz
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2008, 2 (01): : 23 - 26
  • [30] Management of pneumothorax after percutaneous CT-guided lung biopsy
    Yamagami, T
    Nakamura, T
    Iida, S
    Kato, T
    Nishimura, T
    CHEST, 2002, 121 (04) : 1159 - 1164