Scanning laser ophthalmoscope imaging of fluorescein-labelled blood cells

被引:16
|
作者
LeGargasson, JF
Paques, M
Guez, JE
Boval, B
Vicaut, E
Hou, X
Grall, Y
Gaudric, A
机构
[1] HOP LARIBOISIERE,DEPT OPHTHALMOL,F-75010 PARIS,FRANCE
[2] HOP LARIBOISIERE,BANQUE SANG,F-75010 PARIS,FRANCE
[3] HOP FERNAND WIDAL,INSERM U141,PARIS,FRANCE
关键词
D O I
10.1007/BF01007838
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To demonstrate the feasibility of a technique for the visualization by scanning laser ophthalmoscope (SLO) of fluorescein-labelled autologous leukocytes and platelets in retinal vessels. Method: Individual blood samples from rats and rabbits were centrifuged to isolate platelets and leukocytes, then passively labelled with fluorescein and reinjected into the same animal. An SLO was used to visualize and record cell displacement in the retinal circulation. Labelled platelets were analysed by flow cytometry. Results: By SLO, platelets appeared as a heterogeneous particle flow, and individual leukocytes appearing as brighter spots could easily be traced, Flow cytometry showed that after labelling platelets were well individualized and their size was slightly increased. Conclusion: Circulating blood cells can be visualized in retinal vessels by a simple method consisting of passive labelling of autologous platelets and leukocytes by fluorescein. No platelet toxicity was detected. This method could be applied to the study of blood cell movement in human retinal vascular diseases.
引用
收藏
页码:56 / 58
页数:3
相关论文
共 50 条
  • [21] SPECIFIC STAINING OF ORNITHOSIS VIRUS BY FLUORESCEIN-LABELLED INCOMPLETE ANTIBODIES
    GOLDIN, RB
    KRASNIK, FI
    ACTA VIROLOGICA, 1963, 7 (06) : 561 - &
  • [22] TOXOPLASMOSIS .1. STUDIES BY FLUORESCEIN-LABELLED ANTIBODY TECHNIQUE
    RUCKERBAUER, GM
    BEAUREGARD, M
    BANNISTER, GL
    ROBERTSON, A
    BOULANGER, P
    CANADIAN JOURNAL OF COMPARATIVE MEDICINE AND VETERINARY SCIENCE, 1963, 27 (02) : 27 - &
  • [23] BINDING OF FLUORESCEIN-LABELLED STAPHYLOCOCCAL ALPHA-TOXOID TO ERYTHROCYTES
    BAREI, GM
    FACKRELL, HB
    CANADIAN JOURNAL OF MICROBIOLOGY, 1979, 25 (11) : 1219 - 1226
  • [24] Non-Rigid Registration of Fluorescein Angiography and Optical Coherence Tomography via Scanning Laser Ophthalmoscope Imaging
    Kamasi, Zeinab Ghasemi
    Mokhtari, Marzieh
    Rabbani, Hossein
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 4415 - 4418
  • [25] SCANNING LASER OPHTHALMOSCOPE (SLO) FOR SEQUENTIAL FLUORESCEIN AND INDOCYANINE GREEN (ICG) ANGIOGRAPHY
    MANDELL, MA
    ELLER, AW
    FRIBERG, TR
    WARNICKI, JW
    REHKOPF, PG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1506 - 1506
  • [26] Simultaneous indocyanine green and fluorescein angiography using a confocal scanning laser ophthalmoscope
    Freeman, WR
    Bartsch, DU
    Mueller, AJ
    Banker, AS
    Weinreb, RN
    ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) : 455 - 463
  • [27] Simultaneous three wavelength imaging with a scanning laser ophthalmoscope
    Reinholz, F
    Ashman, RA
    Eikelboom, RH
    CYTOMETRY, 1999, 37 (03): : 165 - 170
  • [28] Modifying a Rodenstock scanning laser ophthalmoscope for imaging densitometry
    Tornow, Ralf-Peter
    Beuel, Stefan
    Zrenner, Eberhart
    Applied Optics, 1997, 36 (22): : 5621 - 5629
  • [29] DIGITAL FUNDUS IMAGING USING A SCANNING LASER OPHTHALMOSCOPE
    MANIVANNAN, A
    SHARP, PF
    PHILLIPS, RP
    FORRESTER, JV
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 (01) : 43 - 56
  • [30] Infrared imaging of choroidal neovascularization by scanning laser ophthalmoscope
    Gelisken, F
    Inhoffen, W
    Schneider, U
    Gonzales, JH
    Kreissig, I
    RETINAL PIGMENT EPITHELIUM AND MACULAR DISEASES, 1998, 62 : 151 - 152