A COMPARISON OF MEASUREMENTS AND CALCULATIONS OF THE EFFECTS OF SCATTERED RADIATION ON DOSIMETER CALIBRATION IN A CALIBRATION RANGE

被引:0
|
作者
Rowan, Matthew S. [1 ]
Blue, Thomas E. [1 ,2 ]
Lahti, Erik [1 ]
Talnagi, Joseph [2 ]
Herminghuysen, Kevin [2 ]
Petrie, Christian M. [1 ]
机构
[1] Ohio State Univ, Nucl Engn Program, Columbus, OH 43210 USA
[2] Ohio State Univ, Nucl Reactor Lab, Columbus, OH 43212 USA
来源
HEALTH PHYSICS | 2013年 / 105卷 / 03期
关键词
Cs-137; dosimetry; scattering;
D O I
10.1097/HP.0b013e318294453e
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The method presented provides an alternative to the shadow shield method for experimentally measuring the contribution due to scattering radiation in a calibration range. Scattering of 0.6616 MeV photons from a Cs-137 irradiator in a calibration range does not only occur due to the walls and floor of the range. It also occurs due to the source material itself, its encapsulation, the brass cup that holds the source, the two stainless tubes that surround the source capsule and the brass cup, and the irradiator structure that surrounds the aforementioned objects. The shadow shield method underestimates this scattering radiation that originates in the irradiator. By measuring the uncollided effective activity using a CZT detector and a total effective activity using a survey meter, the contribution of scattered radiation (including all of the above-mentioned sources of scatter) to the effective source activity is able to be measured. In this paper, the measured mean effective source activities for a Cs-137 irradiator in a calibration range are reported for a CZT detector and a survey meter. The measured activities are compared among themselves and with the results of MCNP calculations. From these comparisons, the new alternative method for measuring the scatter contribution was validated by agreement in both the MCNP calculations and experimental measurements that scattering contributed about 28% to the overall effective activity of the range.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 50 条
  • [41] Low radiation dose calibration and theoretical model of an optical fiber dosimeter for the International Space Station
    Di Francesca, Diego
    Balcon, Nicolas
    Cheiney, Pierrick
    Chesta, Enrico
    Clement, Florence
    Girard, Sylvain
    Mekki, Julien
    Melin, Gilles
    Morana, Adriana
    Roche, Martin
    Ricci, Daniel
    APPLIED OPTICS, 2023, 62 (16) : E43 - E50
  • [42] Calibration of the MKD-04 Scintillation Dosimeter for γ Radiation from a 192Ir Source
    V. N. Vasil’ev
    A. V. Sumin
    A. M. Medvedkov
    D. A. Kokontsev
    V. A. Titova
    A. A. Kokontsev
    A. Yu. Smyslov
    Biomedical Engineering, 2020, 54 : 113 - 116
  • [43] SPECTRAL MEASUREMENTS AND MONTE-CARLO CALCULATIONS OF SCATTERED RADIATION FROM THERAPEUTIC RADIATION SOURCES
    ENNOW, K
    JESSEN, KA
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1975, 14 (03): : 262 - 272
  • [45] Calibration and validation measurements of the Extended-range Bonner sphere spectrometer
    Gong, Yiwei
    Wen, Zhiwen
    Luo, Peng
    Song, Shiyu
    Huang, Yuxuan
    Ran, Jianling
    Tang, Xiaoqin
    Jiang, Yue
    Chen, Zhiqiang
    Xu, Junkui
    JOURNAL OF INSTRUMENTATION, 2024, 19 (06):
  • [46] The field of scattered radiation in the tunnel of the proton storage ring HERA: measurements and calculations
    Dinter, H
    Leuschner, A
    Tesch, K
    Dworak, D
    Loskiewicz, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 438 (2-3): : 560 - 572
  • [47] CALIBRATION OF RADIATION SOURCES AND DETECTORS OVER A BROAD RANGE OF MEASUREMENT OF THE ENERGY OF OPTICAL RADIATION
    Kuvaldin, E., V
    MEASUREMENT TECHNIQUES, 2019, 61 (12) : 1181 - 1186
  • [48] Solar-radiation based calibration in the range 740 to 2400 nm
    Biggar, SF
    Thome, KJ
    Spyak, PR
    Zalewski, EF
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES III, 1999, 3870 : 228 - 233
  • [49] Calibration of Radiation Sources and Detectors Over a Broad Range of Measurement of the Energy of Optical Radiation
    E. V. Kuvaldin
    Measurement Techniques, 2019, 61 : 1181 - 1186
  • [50] Effect of CT Calibration Phantom Size On the Range in Proton Radiation Therapy
    Li, H.
    Liu, R.
    Wu, R.
    Sahoo, N.
    Mohan, R.
    Gillin, M.
    Zhu, X.
    MEDICAL PHYSICS, 2008, 35 (06)