A COMPARISON OF MEASUREMENTS AND CALCULATIONS OF THE EFFECTS OF SCATTERED RADIATION ON DOSIMETER CALIBRATION IN A CALIBRATION RANGE

被引:0
|
作者
Rowan, Matthew S. [1 ]
Blue, Thomas E. [1 ,2 ]
Lahti, Erik [1 ]
Talnagi, Joseph [2 ]
Herminghuysen, Kevin [2 ]
Petrie, Christian M. [1 ]
机构
[1] Ohio State Univ, Nucl Engn Program, Columbus, OH 43210 USA
[2] Ohio State Univ, Nucl Reactor Lab, Columbus, OH 43212 USA
来源
HEALTH PHYSICS | 2013年 / 105卷 / 03期
关键词
Cs-137; dosimetry; scattering;
D O I
10.1097/HP.0b013e318294453e
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The method presented provides an alternative to the shadow shield method for experimentally measuring the contribution due to scattering radiation in a calibration range. Scattering of 0.6616 MeV photons from a Cs-137 irradiator in a calibration range does not only occur due to the walls and floor of the range. It also occurs due to the source material itself, its encapsulation, the brass cup that holds the source, the two stainless tubes that surround the source capsule and the brass cup, and the irradiator structure that surrounds the aforementioned objects. The shadow shield method underestimates this scattering radiation that originates in the irradiator. By measuring the uncollided effective activity using a CZT detector and a total effective activity using a survey meter, the contribution of scattered radiation (including all of the above-mentioned sources of scatter) to the effective source activity is able to be measured. In this paper, the measured mean effective source activities for a Cs-137 irradiator in a calibration range are reported for a CZT detector and a survey meter. The measured activities are compared among themselves and with the results of MCNP calculations. From these comparisons, the new alternative method for measuring the scatter contribution was validated by agreement in both the MCNP calculations and experimental measurements that scattering contributed about 28% to the overall effective activity of the range.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 50 条
  • [1] EVALUATION OF THE EFFECTS OF SCATTERED RADIATION ON DOSIMETER CALIBRATION IN A CALIBRATION RANGE
    Petrie, Christian M.
    Nimps, Ronni G.
    Blue, Thomas E.
    Herminghuysen, Kevin
    HEALTH PHYSICS, 2013, 104 (01): : 68 - 77
  • [3] TIMING DEVICE USED AT RADIATION DOSIMETER CALIBRATION
    SAMUELSON, G
    BENGTSSON, LG
    HEALTH PHYSICS, 1975, 28 (04): : 464 - 466
  • [4] EVALUATION OF SCATTERED RADIATION IN A CALIBRATION RANGE USING EXPOSURE RATE ENERGY SPECTRA
    Petrie, Christian M.
    Blue, Thomas E.
    Herminghuysen, Kevin
    HEALTH PHYSICS, 2012, 102 (01): : 71 - 80
  • [5] CALIBRATION PROCEDURES FOR RADIATION MEASUREMENTS
    MOTZ, JW
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (02): : 460 - &
  • [6] CALIBRATION OF, AND MEASUREMENTS WITH, A NEUTRON DOSIMETER CONSISTING OF FISSION FOILS AND AN SSNTD
    MEDVECZKY, L
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1990, 17 (01): : 51 - 54
  • [7] Comparison of measurements - Calibration and validation
    Newman, Paul A.
    Observing Systems for Atmospheric Composition: Satellite, Aircraft, Sensor Web and Ground-Based Observational Methods and Strategies, 2007, : 182 - 199
  • [8] Simulation of gamma minitype reference radiation for calibration of personal dosimeter
    Yi-Xin Liu
    Yi-Kun Qian
    Zhi-Qiang Chen
    Biao Wei
    Peng Feng
    Ben-Jiang Mao
    NuclearScienceandTechniques, 2020, 31 (01) : 114 - 124
  • [9] Simulation of gamma minitype reference radiation for calibration of personal dosimeter
    Liu, Yi-Xin
    Qian, Yi-Kun
    Chen, Zhi-Qiang
    Wei, Biao
    Feng, Peng
    Mao, Ben-Jiang
    NUCLEAR SCIENCE AND TECHNIQUES, 2020, 31 (01)
  • [10] Simulation of gamma minitype reference radiation for calibration of personal dosimeter
    Yi-Xin Liu
    Yi-Kun Qian
    Zhi-Qiang Chen
    Biao Wei
    Peng Feng
    Ben-Jiang Mao
    Nuclear Science and Techniques, 2020, 31