Use of intubation introducers through a supraglottic airway to facilitate tracheal intubation: a brief review

被引:1
|
作者
Wong, David T. [1 ]
Yang, Jaisy J. [2 ]
Mak, Hannah Y. [1 ]
Jagannathan, Narasimhan [3 ]
机构
[1] Univ Toronto, Toronto Western Hosp, Dept Anesthesia, Toronto, ON M5T 2S8, Canada
[2] Univ Toronto, Toronto Western Hosp, Fac Med, Toronto, ON M5T 2S8, Canada
[3] Northwestern Univ, Sch Med, Dept Anesthesiol, Chicago, IL USA
关键词
LARYNGEAL MASK AIRWAY; GUM ELASTIC BOUGIE; FIBEROPTIC-GUIDED INTUBATION; DIFFICULT PEDIATRIC AIRWAY; TREACHER-COLLINS SYNDROME; ENDOTRACHEAL INTUBATION; OROTRACHEAL INTUBATION; EXCHANGE CATHETER; AINTREE CATHETER; I-GEL;
D O I
10.1007/s12630-012-9714-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This article is a narrative review regarding the usage and effectiveness of introducers or catheters to facilitate tracheal intubation through a supraglottic airway (SGA) as an alternative intubation technique in normal and difficult airway management. Relevant articles were obtained through Medline (1948-July 2011). The articles were subsequently cross-referenced for additional literature, and only articles published in English were included. In this review, we consider 32 reports using the LMA Classic (TM), LMA Unique (TM), LMA ProSeal (TM), LMA Supreme (TM), AuraOnce (TM), and i-gel (TM) as SGA conduits for intubation. In 13 articles, the use of an Aintree Intubation Catheter was described as an intubation introducer and resulted in high success rates in both elective and emergent situations. Eight studies used a guidewire exchange catheter technique. Although blind intubation using a guidewire resulted in a high failure rate, these studies found that using a bronchoscope improved successful intubation. Ten studies showed that insertion of a gum elastic bougie with a bronchoscope as an intubation introducer has high success rates compared with blind bougie insertion. One article described the use of a small endotracheal tube as an intermediary for tracheal intubation. In failed intubation scenarios, supraglottic airways, such as the LMA Classic (TM) or LMA ProSeal (TM) can serve as a conduit for tracheal intubation. A number of techniques using introducers or catheters can facilitate the insertion of an adequately sized endotracheal tube, particularly guided by a bronchoscope. Usage of introducers or catheters through a supraglottic airway may be a useful alternative intubation technique in difficult airway management.
引用
收藏
页码:704 / 715
页数:12
相关论文
共 50 条
  • [21] Optimal size and length of the endotracheal tube for tracheal intubation via supraglottic airway devices
    Xue, Fu S.
    Xiong, Jun
    Yuan, Yu J.
    Wang, Qiang
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (06): : 624 - 625
  • [22] Use of a fiberoptic bronchoscope to facilitate tracheal intubation after failed intubation using the Airtraq® laryngoscope
    Xue, F. S.
    He, N.
    Liu, J. H.
    Zhang, Y. M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (02) : 256 - 257
  • [23] Supraglottic Airway Versus Tracheal Intubation in Adults With Out-of-Hospital Cardiac Arrest
    Zhao, Yang
    Zang, Bin
    Wang, Qian
    CRITICAL CARE MEDICINE, 2024, 52 (07) : e407 - e408
  • [24] Optimal size and length of the endotracheal tube for tracheal intubation via supraglottic airway devices
    Fu S. Xue
    Jun Xiong
    Yu J. Yuan
    Qiang Wang
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2010, 57 : 624 - 625
  • [25] Supraglottic airway devices as a strategy for unassisted tracheal intubation: A network meta-analysis
    Ahn, EunJin
    Choi, GeunJoo
    Kang, Hyun
    Baek, ChongWha
    Jung, YongHun
    Woo, YoungCheol
    Bang, SiRa
    PLOS ONE, 2018, 13 (11):
  • [26] Tracheal Intubation Through the I-gel™ Supraglottic Airway Versus the LMA Fastrach™: A Randomized Controlled Trial
    Halwagi, Antoine Elie
    Massicotte, Nathalie
    Lallo, Alexandre
    Gauthier, Alain
    Boudreault, Daniel
    Ruel, Monique
    Girard, Francois
    ANESTHESIA AND ANALGESIA, 2012, 114 (01): : 152 - 156
  • [27] Use of a guide wire to facilitate tracheal intubation with the Bullard laryngoscope
    Ringwalt, EC
    ANESTHESIOLOGY, 1998, 89 (03) : 805 - 805
  • [28] Blind intubation through the supraglottic airway laryngopharyngeal tube with a biohazard suit
    Aleksandrowicz, Sebastian
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (10): : 2040 - 2040
  • [29] Intubation with a VivaSight Single Lumen Through a Supraglottic Airway Device Response
    Gaitini, Luis
    Yanovski, Boris
    Somri, Mostafa
    Hagberg, Carin
    Mora, Pedro Charco
    Vaida, Sonia
    ANESTHESIA AND ANALGESIA, 2013, 117 (03): : 749 - 750
  • [30] Advanced airway management in drowning: Pre-hospital tracheal intubation as compared to supraglottic airway device
    Culp, William C.
    Stevens, Troy D.
    Davis, Peter
    RESUSCITATION, 2024, 199