A Novel Approach for Fault Location of Overhead Transmission Line With Noncontact Magnetic-Field Measurement

被引:57
|
作者
Huang, Qi [1 ]
Zhen, Wei [2 ]
Pong, Philip W. T. [3 ]
机构
[1] Univ Elect Sci & Technol China, Sichuan Prov Key Lab Power Syst Wide Area Measure, Chengdu 611731, Sichuan, Peoples R China
[2] Sichuan Elect Power Test & Res Inst, Chengdu 610072, Sichuan, Peoples R China
[3] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Fault location; magnetoresistive magnetic sensor; noncontact magnetic-field measurement; overhead transmission line;
D O I
10.1109/TPWRD.2012.2190427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Prompt and accurate location of faults in a large-scale transmission system can accelerate system restoration, reduce outage time, and improve system reliability. Traditional approaches are categorized into traveling-wave-based and impedance-based measurement techniques. The traveling-wave-based approach requires detection devices to connect to the high-voltage transmission line, making the solution complex and costly. And the impedance-measurement-based approach is highly dependent on the quality of the signal and affected by fault resistance, ground resistance and non-homogeneity in line configuration. Hence, these approaches may cause a location error that is unacceptable in certain operation cases. In this paper, a novel approach based on noncontact magnetic-field measurement is proposed. With the magnetic field measured along the transmission line by using highly sensitive, broadband, and a low-cost magnetoresistive magnetic sensor, the fault span can be located. The collected data can be further used for identifying the fault type and location within the fault span. The overall system was designed and numerical simulations were performed on typical tower configurations. The simulated results verify the validity of the proposed scheme.
引用
收藏
页码:1186 / 1195
页数:10
相关论文
共 50 条
  • [21] Measurement based fault location in Three-Terminal Overhead Line and Underground Cable
    Fulczyk, M.
    Balcerek, P.
    Rosolowski, E.
    Izykowski, J.
    Saha, M. M.
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [22] Fault Location in Overhead Transmission Lines Based on Magnetic Signatures and on the Extended Kalman Filter
    De Oliveira Neto, Jesus Anicio
    Sartori, Carlos Antonio Franca
    Manassero Junior, Giovanni
    IEEE ACCESS, 2021, 9 : 15259 - 15270
  • [23] Mitigation of 50 Hz Magnetic Field Produced by an Overhead Transmission Line
    Ippolito, Mariano Giuseppe
    Puccio, Andrea
    Ala, Guido
    Ganci, Salvatore
    Filippone, Giovanni
    2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [24] A Novel Approach to Noninvasive Measurement of Overhead Line Impedance Parameters
    Ritzmann, Deborah
    Rens, Johan
    Wright, Paul S.
    Holderbaum, William
    Potter, Ben
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (06) : 1155 - 1163
  • [25] Transmission Line Protection and Fault Location Based on Travelling Wave Measurement
    Siozinys, V.
    Urniezius, R.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (09) : 21 - 24
  • [26] Optimal estimate of transmission line fault location considering measurement errors
    Liao, Yuan
    Kezunovic, Mladen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) : 1335 - 1341
  • [28] Study on travelling wave fault location for overhead line combined with cable in railway automatic and continuous transmission line
    He, Zheng-You
    Yang, Jian-Wei
    Zhou, Chao
    Luo, Guo-Min
    Dalian Haishi Daxue Xuebao/Journal of Dalian Maritime University, 2007, 33 (03): : 46 - 50
  • [29] Fault location of high voltage overhead transmission line based on ACO-ENN algorithm
    Zhang, Guangxin
    Zhang, Qi
    Ma, Jun
    Liu, Gang
    Sun, Dong
    Zhang, Zimeng
    INTERNATIONAL JOURNAL OF CRITICAL INFRASTRUCTURES, 2023, 19 (06) : 544 - 557
  • [30] A novel practical accurate fault location algorithm for HV transmission line
    Teng, L.
    Liu, W.
    Li, Y.
    Li, G.
    Qin, H.
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2001, 25 (18): : 24 - 27