Comparison of results after anterior cruciate ligament reconstruction using a four-strand single semitendinosus or a semitendinosus and gracilis tendon

被引:27
|
作者
Kyung, Hee-Soo [1 ]
Lee, Hyun-Joo [1 ]
Oh, Chang-Wug [1 ]
Hong, Han-Pyo [1 ]
机构
[1] Kyungpook Natl Univ Hosp, Sch Med, Dept Orthopaed Surg, Daegu 700721, South Korea
关键词
Anterior cruciate ligament reconstruction; Semitendinosus; Gracilis; Single semitendinosus; KNEE FLEXOR STRENGTH; PATELLAR TENDON; GRAFT LENGTH; BONE TUNNEL; PERIOSTEUM; AUTOGRAFTS; TISSUE;
D O I
10.1007/s00167-014-3076-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To compare the clinical and functional results of anterior cruciate ligament (ACL) reconstruction using an autologous four-strand single semitendinosus (ST) tendon or a ST and gracilis tendon. It was hypothesized that successful ACL reconstruction using a single ST tendon without the gracilis tendon could provide comparable knee stability and reduce donor site morbidity. This study evaluated 144 cases of single-bundle ACL reconstruction using an autologous hamstring tendon. The ST group included 85 cases of reconstruction using a single ST tendon, and the ST/G group included 59 cases of reconstruction using a ST tendon and a gracilis tendon. An extracortical suspension device and a suture tied around a screw post with an additional bioabsorbable screw were used to fix the femoral and tibial tunnels, respectively. Clinical evaluations involved the Lachman, pivot-shift, and one-leg hop tests; an isokinetic test; a KT-2000 arthrometer; an assessment of return to pre-injury activities; and Lysholm, Tegner activity, and International Knee Documentation Committee (IKDC) subjective scores. No significant differences were found between the ST and ST/G groups with respect to the Lysholm, Tegner activity, and subjective IKDC scores; the Lachman, pivot-shift, and one-leg hop tests; KT-2000 arthrometer side-to-side differences; or return to pre-injury activities. However, mean peak torque deficit, as determined using the isokinetic test during flexion at 60A degrees/s, was significantly lower in the ST group than in the ST/G group (p = 0.047). This study showed good results for ACL reconstruction using a single ST tendon without deterioration of stability. This provides the evidence that ACL reconstruction using a single ST tendon without the gracilis tendon decreases donor site morbidity without compromising joint stability. IV.
引用
收藏
页码:3238 / 3243
页数:6
相关论文
共 50 条
  • [21] Muscle and tendon morphology after reconstruction of the anterior cruciate ligament with autologous semitendinosus-gracilis graft
    Williams, GN
    Snyder-Mackler, L
    Barrance, PJ
    Axe, MJ
    Buchanan, TS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09): : 1936 - 1946
  • [22] Anterior cruciate ligament reconstruction with a four-strand hamstring tendon autograft
    Williams, RJ
    Hyman, J
    Petrigliano, F
    Rozental, T
    Wickiewicz, TL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02): : 225 - 232
  • [23] Anterior knee symptoms after four-strand hamstring tendon anterior cruciate ligament reconstruction
    D.D.M. Spicer
    S.E. Blagg
    A.J. Unwin
    R.L. Allum
    Knee Surgery, Sports Traumatology, Arthroscopy, 2000, 8 : 286 - 289
  • [24] Anterior knee symptoms after four-strand hamstring tendon anterior cruciate ligament reconstruction
    Spicer, DDM
    Blagg, SE
    Unwin, AJ
    Allum, RL
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2000, 8 (05) : 286 - 289
  • [25] Four-strand hamstring graft is stiffer than a tripled semitendinosus graft in anterior cruciate ligament reconstruction: a cadaveric study
    Frans J. A. Hagemans
    Karlijn L. J. van Overvest
    Jacco A. C. Zijl
    Duncan E. Meuffels
    Journal of Experimental Orthopaedics, 7
  • [26] Anterior cruciate ligament reconstruction with multistranded autogenous semitendinosus tendon
    Maeda, A
    Shino, K
    Horibe, S
    Nakata, K
    Buccafusca, G
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (04): : 504 - 509
  • [27] Four-strand hamstring graft is stiffer than a tripled semitendinosus graft in anterior cruciate ligament reconstruction: a cadaveric study
    Hagemans, Frans J. A.
    van Overvest, Karlijn L. J.
    Zijl, Jacco A. C.
    Meuffels, Duncan E.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
  • [28] A comparison of quadruple semitendinosus and patellar tendon grafts in reconstruction of the anterior cruciate ligament
    Eriksson, K
    Anderberg, P
    Hamberg, P
    Löfgren, AC
    Bredenberg, M
    Westman, I
    Wredmark, T
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03): : 348 - 354
  • [29] Does harvesting of the semitendinosus tendon really spare the gracilis in pediatric anterior cruciate ligament reconstruction?
    Testory, Maxime
    Cavaignac, Etienne
    Vial, Julie
    de Gauzy, Jerome Sales
    Accadbled, Franck
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2022, 16 (02) : 147 - 151
  • [30] Muscle strength recovery versus semitendinosus and gracilis tendon regeneration after harvesting for anterior cruciate ligament reconstruction
    Zaccherotti, Giovanni
    Olmastroni, Maristella
    JOURNAL OF SPORTS SCIENCES, 2015, 33 (20) : 2149 - 2156