Validation of a wireless shoe insole for ground reaction force measurement

被引:66
|
作者
Burns, Geoffrey T. [1 ]
Zendler, Jessica Deneweth [1 ]
Zernicke, Ronald F. [1 ,2 ,3 ]
机构
[1] Univ Michigan, Sch Kinesiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI 48109 USA
关键词
Running; biomechanics; plantar force; wireless measurement; contact time; PEDAR MOBILE SYSTEM; HUMAN WALKING; PRESSURE; RELIABILITY; VALIDITY; VARIABILITY; SPEED;
D O I
10.1080/02640414.2018.1545515
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Ground reaction force measurements are a fundamental element of kinetic analyses of locomotion, yet they are traditionally constrained to laboratory settings or stationary frames. This study assessed the validity and reliability of a new wireless in-shoe system (Novel Loadsol/Pedoped) for field-based ground reaction force measurement in hopping, walking, and running. Twenty participants bilaterally hopped on a force plate and walked (5 km/hr) and ran (10 km/hr) on an instrumented treadmill on two separate days while wearing the insoles. GRFs were recorded simultaneously on each respective system. Peak GRF in hopping and peak GRF, contact time (CT), and impulse (IMP) in walking and running were compared on a per-hop and step-by-step basis. In hopping, the insoles demonstrated excellent agreement with the force plate (ICC: 0.96). In walking and running, the insoles demonstrated good-to-excellent agreement with the treadmill across all measures (ICCs: 0.88-0.96) and were reliable across sessions (ICCs within 0.00-0.03). A separate verification study with ten participants was conducted to assess a correction algorithm for further agreement improvement but demonstrated little meaningful change in systemic agreements. These results indicated that the Novel Loadsol system is a valid and reliable tool for wireless ground reaction force measurement in hopping, walking, and running.
引用
收藏
页码:1129 / 1138
页数:10
相关论文
共 50 条
  • [31] HYSTERESIS COMPENSATION FOR GROUND CONTACT FORCE MEASUREMENT WITH SHOE-EMBEDDED AIR PRESSURE SENSORS
    Chinimilli, Prudhvi Tej
    Wachtel, Sean Wolfgang
    Polygerinos, Panagiotis
    Zhang, Wenlong
    PROCEEDINGS OF THE ASME 9TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2016, VOL 1, 2017,
  • [32] MICRO FORCE PLATE ARRAY FOR MEASUREMENT OF GROUND REACTION FORCE OF INSECT RUNNING
    Takahashi, H.
    Matsumoto, K.
    Shimoyama, I.
    26TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2013), 2013, : 59 - 62
  • [33] Wearable force sensor with parallel structure for measurement of ground-reaction force
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    MEASUREMENT, 2007, 40 (06) : 644 - 653
  • [34] Validation of Electronic Weighing Device for Vertical Ground Reaction Force and Centre of Pressure Measurement; and Clinical Metrics Derivation
    Yeo, Ying Heng
    Razali, Muhammad Fauzinizam
    Ripin, Zaidi Mohd
    J., Nur-Akasyah
    Ridzwan, Mohamad Ikhwan Zaini
    Tan, Alexander Wai Teng
    Tay, Jia Yi
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2024, 20 (04): : 888 - 901
  • [35] GAIT ANALYSIS OF HEMIPLEGIC PATIENTS BY MEASUREMENT OF GROUND REACTION FORCE
    MORITA, S
    YAMAMOTO, H
    FURUYA, K
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1995, 27 (01): : 37 - 42
  • [36] Ground reaction force estimation using an insole-type pressure mat and joint kinematics during walking
    Jung, Yihwan
    Jung, Moonki
    Lee, Kunwoo
    Koo, Seungbum
    JOURNAL OF BIOMECHANICS, 2014, 47 (11) : 2693 - 2699
  • [37] A Systematic Approach to the Design and Characterization of a Smart Insole for Detecting Vertical Ground Reaction Force (vGRF) in Gait Analysis
    Tahir, Anas M.
    Chowdhury, Muhammad E. H.
    Khandakar, Amith
    Al-Hamouz, Sara
    Abdalla, Merna
    Awadallah, Sara
    Reaz, Mamun Bin Ibne
    Al-Emadi, Nasser
    SENSORS, 2020, 20 (04)
  • [38] Foot centre of pressure and ground reaction force during quadriceps resistance exercises; a comparison between force plates and a pressure insole system
    Jonsson, Maria
    Munkhammar, Tobias
    Norrbrand, Lena
    Berg, Hans E.
    JOURNAL OF BIOMECHANICS, 2019, 87 : 206 - 210
  • [39] A Fuzzy Logic System Tuned with Particle Swarm Optimization for Gait Segmentation using Insole Measured Ground Reaction Force
    Long, Yi
    Du, Zhijiang
    Wang, Weidong
    2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 513 - 518
  • [40] A comparison of ground reaction forces determined by portable force-plate and pressure-insole systems in alpine skiing
    Nakazato, Kosuke
    Scheiber, Peter
    Mueller, Erich
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2011, 10 (04) : 754 - 762