ACCURACY OF END-TIDAL CO2 CAPNOMETERS IN POST-CARDIAC SURGERY PATIENTS DURING CONTROLLED MECHANICAL VENTILATION

被引:19
|
作者
Heines, Serge J. H. [1 ]
Strauch, Ulrich [1 ]
Roekaerts, Paul M. H. J. [1 ]
Winkens, Bjorn [2 ]
Bergmans, Dennis C. J. J. [1 ]
机构
[1] Maastricht Univ, Dept Intens Care, Med Ctr, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, Dept Methodol & Stat, NL-6202 AZ Maastricht, Netherlands
来源
JOURNAL OF EMERGENCY MEDICINE | 2013年 / 45卷 / 01期
关键词
end-tidal carbon dioxide; capnography; capnometer; monitoring; carbon dioxide; blood gas analysis; CARBON-DIOXIDE; ARTERIAL; TRAUMA; CAPNOGRAPHY; CARE;
D O I
10.1016/j.jemermed.2012.11.019
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The determination of end-tidal carbon dioxide (etCO(2)) is very helpful in cardiac resuscitation for confirmation and monitoring of endotracheal tube placement and as an indicator of return of circulation and effectiveness of chest compressions. There is now also widespread use of capnometry on-site at emergency and trauma fields. Objective: We studied the accuracy and correlation of three capnometers (EMMA, Medtronic, and Evita) with partial pressure of arterial CO2 (PaCO2) measurements. Methods: The three capnometers were placed in-line in the ventilator tubing of the patient. Forty sedated and mechanically ventilated post-cardiac surgery patients were studied. Twenty consecutive etCO(2) values were collected simultaneously from all three monitors while drawing an arterial blood sample. Paired sample t-test and Pearson correlation were used to compare the capnometers and their correlation with PaCO2. Results: The correlation of etCO(2) measurements between all three capnometers was good (Emma vs. Evita: 0.874, Emma vs. Medtronic: 0.949, Evita vs. Medtronic: 0.878). The correlation of PaCO2 with the Evita is the lowest (0.671) as compared to the EMMA (0.693) and the Medtronic (0.727). The lowest dispersion of the difference between etCO(2) and PaCO2 was seen in EMMA (3.30), the highest in Evita (3.98). Conclusions: A good correlation between etCO(2) and PaCO2 was shown with the three capnometers in the present study. However, etCO(2) measurements were not valid to estimate PaCO2 in these patients. Therefore, capnometry cannot be used to replace serial blood gas analyses completely, but may be a good cardiopulmonary trend monitor and alerting system in catastrophic events. (c) 2013 Elsevier Inc.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [1] VENTILATORY FREQUENCY INFLUENCES ACCURACY OF END-TIDAL CO2 MEASUREMENTS - ANALYSIS OF 7 CAPNOMETERS
    FROM, RP
    SCAMMAN, FL
    ANESTHESIA AND ANALGESIA, 1988, 67 (09): : 884 - 886
  • [2] End-tidal CO2 detection during cadaveric ventilation
    Coats, T. J.
    Morgan, B.
    Robinson, C.
    Biggs, M.
    Adnan, A.
    Rutty, G.
    EMERGENCY MEDICINE JOURNAL, 2015, 32 (09) : 753 - 754
  • [3] Tidal ventilation distribution during pressure-controlled ventilation and pressure support ventilation in post-cardiac surgery patients
    Blankman, P.
    van der Kreeft, S. M.
    Gommers, D.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (08) : 997 - 1006
  • [4] THE INFLUENCE OF CO2 PRODUCTION AND PHYSIOLOGICAL DEADSPACE ON END-TIDAL CO2 DURING CONTROLLED VENTILATION - A STUDY USING A MECHANICAL MODEL
    STOCKWELL, MA
    BRUCE, W
    SONI, N
    ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (04) : 482 - 486
  • [5] Use of Maximum End-Tidal CO2 Values to Improve End-Tidal CO2 Monitoring Accuracy
    Galia, Fabrice
    Brimioulle, Serge
    Bonnier, Frederic
    Vandenbergen, Nicolas
    Dojat, Michel
    Vincent, Jean-Louis
    Brochard, Laurent J.
    RESPIRATORY CARE, 2011, 56 (03) : 278 - 283
  • [6] End-Tidal CO2 Measurements with Noninvasive Ventilation
    Nuccio, Paul
    Hochstetler, Gary
    Jackson, Michael
    ANESTHESIA AND ANALGESIA, 2007, 105 : S111 - S111
  • [7] Elevation of end-tidal CO2 during exercise is attenuated in patients with cardiac amyloidosis
    Atsushi Shibata
    Yasuhiro Izumiya
    Toshitake Yoshida
    Akiko Tanihata
    Yumi Yamaguchi
    Ryoko Kitada
    Daiju Fukuda
    Heart and Vessels, 2024, 39 : 340 - 348
  • [8] Elevation of end-tidal CO2 during exercise is attenuated in patients with cardiac amyloidosis
    Shibata, Atsushi
    Izumiya, Yasuhiro
    Yoshida, Toshitake
    Tanihata, Akiko
    Yamaguchi, Yumi
    Kitada, Ryoko
    Fukuda, Daiju
    HEART AND VESSELS, 2024, 39 (04) : 340 - 348
  • [9] Not the end of end-tidal CO2
    Shah, Kaushal
    INTERNAL AND EMERGENCY MEDICINE, 2009, 4 (01) : 39 - 40
  • [10] Not the end of end-tidal CO2
    Kaushal Shah
    Internal and Emergency Medicine, 2009, 4 : 39 - 40