Fractures of the distal clavicle: outcomes and complications of surgical treatment using the hook plate

被引:0
|
作者
Morales Davila, J. [1 ]
Domingo Trepat, A. [1 ]
Rios Martin, M. [1 ]
Carreno Delgado, A. [1 ]
Ballesteros Betancourt, J. [1 ]
Garcia Elvira, R. [1 ]
Garcia Tarrino, R. [1 ]
Camacho, P. [1 ]
Zumbado, A. [1 ]
Prat Fabregat, S. [1 ]
机构
[1] Hosp Clin Barcelona, Dept Orthoped Surg & Traumatol, Barcelona, Spain
关键词
Clavicle; Fractures; bone; Surgical procedures; operative; CORACOCLAVICULAR SCREW FIXATION; UNSTABLE FRACTURES; LATERAL END; ACROMIOCLAVICULAR JOINT; KIRSCHNER WIRE; SHOULDER; MIGRATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim. Distal clavicle fractures account for 15% of all clavicle fractures. Neer type II lateral end fractures are associated with non-union rates of 30%. Further, fixations by way of hook plates seem to have proved successful. We report our experience using the hook plate in the treatment of distal clavicle fractures. Methods. Twenty four patients with distal clavicle fractures were operated on and had an AO hook plate (Synthesi(R)) implanted. 20 men and 4 women were retrospectively reviewed. The average age at time of surgery was 35 (range 18-74). All the patients presented with a Neer type II distal fracture. The average follow-up was 20 months (range 10 - 26), and the patients were radiologically and clinically evaluated during this period of time. The Constant-Murley score was used to measure shoulder movement, strength and pain. The patient's ability to carry out his or her daily-life activities was measured with both the Constant-Murley score and the Oxford Test. Results. Twenty four patients achieved clinical and radiologic union and one patient suffered from failure of fixation. All the plates were removed. In the last visit, the mean Constant-Murley score and the mean Oxford score were 85 and 42, respectively, and seven patients presented with osteolysis. All patients were able to return to their preinjury activity level. Conclusion. Hook plate fixations of distal clavicle fractures offer good functional results with the shortcoming of plate removal after bone fusion is achieved. Osteolysis is a common complication associated with keeping the implant for over 6 months and it did not result in poor functional outcomes.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 50 条
  • [31] The Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocation and Distal Clavicle Fractures
    Shaty, Wahby
    ORTHOPEDIC REVIEWS, 2024, 16
  • [32] Neer type II distal clavicle fractures: hook plate versus transacromial pin
    Mechchat, Atif
    Elidrissi, Mohammed
    Shimi, Mohammed
    Elibrahimi, Abdelhalim
    Elmrini, Abdelmajid
    PAN AFRICAN MEDICAL JOURNAL, 2015, 20
  • [33] Clinical therapeutic effects of AO/ASIF clavicle hook plate on distal clavicle fractures and acromioclavicular joint dislocations
    Dou, Qingjun
    Ren, Xiaofeng
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (04) : 868 - 871
  • [34] Fractures of the distal third of the clavicle treated by hook plating
    A.D. Tambe
    P. Motkur
    A. Qamar
    S. Drew
    S.M. Turner
    International Orthopaedics, 2006, 30 : 7 - 10
  • [35] Surgical Treatment of Zone 1 Fifth Metatarsal Base Fractures Using the Locking Compression Plate Distal Ulna Hook Plate
    Zhao, Jingjing
    Yu, Bin
    Xie, Ming
    Huang, Ruokun
    Xiao, Kai
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2017, 107 (05) : 369 - 374
  • [36] Surgical Treatment of Adolescent Clavicle Fractures: Results and Complications
    McIntosh, Amy L.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (04) : S41 - S43
  • [37] Fractures of the distal third of the clavicle treated by hook plating
    Tambe, AD
    Motkur, P
    Qamar, A
    Drew, S
    Turner, SM
    INTERNATIONAL ORTHOPAEDICS, 2006, 30 (01) : 7 - 10
  • [38] Clavicle Hook Plate for Neer Type II Lateral Clavicle Fractures
    Bhattacharyya, Rahul
    Sharma, Kavita
    Mukherjee, Pavel
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (03) : E30 - E30
  • [39] The Clavicle Hook Plate for Neer Type II Lateral Clavicle Fractures
    Renger, R. J.
    Roukema, G. R.
    Reurings, J. C.
    Raams, P. M.
    Font, J.
    Verleisdonk, E. J. M. M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (08) : 570 - 574
  • [40] Surgical Treatment of Mid-Shaft Clavicle Fractures: Plate Fixation and Clinical Outcomes
    Ozan, Firat
    Dogar, Fatih
    Altay, Taskin
    Mujde, Salih
    Koyuncu, Semmi
    Vatansever, Fatih
    Bulut, Tugrul
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 : 792 - 796