Effect of light sources and curing mode techniques on sorption, solubility and biaxial flexural strength of a composite resin

被引:13
|
作者
Carvalho, Andreia Assis [1 ]
Lima Moreira, Francine do Couto
Fonseca, Rodrigo Borges
Soares, Carlos Jose [2 ]
Franco, Eduardo Batista [3 ]
de Souza, Joao Batista
Lopes, Lawrence Gonzaga
机构
[1] Univ Fed Goias, Fac Odontol, Dept Prevencao & Reabilitacao Oral, Setor Univ,Sch Dent, BR-74605220 Goiania, Go, Brazil
[2] Univ Fed Uberlandia, Sch Dent, BR-38400 Uberlandia, MG, Brazil
[3] Univ Sao Paulo, Bauru Sch Dent, Bauru, SP, Brazil
关键词
Composite resins; Solubility; Solvents; Mechanical phenomena; DENSITY; STRESS; CONTRACTION; CONVERSION; ENERGY; UNITS;
D O I
10.1590/S1678-77572012000200021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A dequate polymerization plays an important role on the longevity of the composite resin restorations. Objectives: The aim of this study was to evaluate the effect of light-curing units, curing mode techniques and storage media on sorption, solubility and biaxial flexural strength (BFS) of a composite resin. Material and Methods: Two hundred and forty specimens were made of one composite resin (Esthet-X) in a stainless steel mold (2 mm x 8 mm 0), and divided into 24 groups (n=10) established according to the 4 study factors: light-curing units: quartz tungsten halogen (QTH) lamp and light-emitting diodes (LED); energy densities: 16 J/cm(2) and 20 J/cm(2); curing modes: conventional (CM) and pulse-delay (PD); and permeants: deionized water and 75% ethanol for 28 days. Sorption and solubility tests were performed according to ISO 4049:2000 specifications. All specimens were then tested for BFS according to ASTM F394-78 specification. Data were analyzed by three-way ANOVA followed by Tukey, Kruskal-Wallis and Mann-Whitney tests (alpha=0.05). Results: In general, no significant differences were found regarding sorption, solubility or BFS means for the light-curing units and curing modes (p>0.05). Only LED unit using 16 J/cm(2) and PD using 10 s produced higher sorption and solubility values than QTH. Otherwise, using CM (16 J/cm(2)), LED produced lower values of BFS than QTH (p<0.05). 75% ethanol permeant produced higher values of sorption and solubility and lower values of BFS than water (p<0.05). Conclusion: Ethanol storage media produced more damage on composite resin than water. In general the LED and QTH curing units using 16 and 20 J/cm(2) by CM and PD curing modes produced no influence on the sorption, solubility or BFS of the tested resin.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 50 条
  • [21] Influence of intermediate resin on the bond strength of light-curing composite resin to polymer substrate
    Kallio, Timo T.
    Lastumaeki, Tapani M.
    Lassila, Lippo V. J.
    Vallittu, Pekka K.
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (03) : 202 - 208
  • [22] Influence of Curing Mode on the Surface Energy and Sorption/Solubility of Dental Self-Adhesive Resin Cements
    Kim, Hyun-Jin
    Bagheri, Rafat
    Kim, Young Kyung
    Son, Jun Sik
    Kwon, Tae-Yub
    MATERIALS, 2017, 10 (02):
  • [23] Effect of citric acid ageing on composite resin microhardness and flexural strength
    da Silva, Patricia Ferreira
    Barragan, Goncalo
    Chasqueira, Filipa
    Arantes e Oliveira, Sofia
    Portugal, Jaime
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2012, 53 (04): : 227 - 232
  • [24] Effect of light-curing distance and curing time on composite microflexural strength
    Al-Zain, Afnan O.
    Platt, Jeffrey A.
    DENTAL MATERIALS JOURNAL, 2021, 40 (01) : 202 - 208
  • [25] Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin composite: Influence of the light-activation mode
    da Silva, Eduardo Moreira
    Almeida, Giselle Soares
    Poskus, Laiza Tatiana
    Antunes Guimaraes, Jos Guilherme
    JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (02) : 161 - 166
  • [26] Effect of light curing sources on microhardness of different composite resins
    Valentino, T. A.
    Calabrez-Filho, S.
    de Menezes, F. C. H.
    Cavalcante, L. M. A.
    Pimenta, L. A. F.
    de Andrade, M. F.
    Dantas, A. A. R.
    Rastelli, A. N. S.
    LASER PHYSICS, 2011, 21 (06) : 1130 - 1134
  • [27] Effect of light emitting diode curing on composite resin microleakage.
    Harada, KM
    Caputo, AA
    Mito, R
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A86 - A86
  • [28] Temperature rise during adhesive and resin composite polymerization with various light curing sources
    Ozturk, B
    Ozturk, AN
    Usumez, A
    Usumez, S
    Özer, F
    OPERATIVE DENTISTRY, 2004, 29 (03) : 325 - 332
  • [29] Effect of light-curing method on wear and hardness of composite resin
    Hammouda, Ibrahim M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (02) : 216 - 222
  • [30] Effect of LED curing light on composite resin depth of cure.
    Dialani, N
    Sung, E
    Caputo, AA
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A86 - A86