CMOS imager non-uniformity response correction-based high-accuracy spot target localization

被引:13
|
作者
Bao, Jingyu [1 ,2 ]
Xing, Fei [1 ,2 ]
Sun, Ting [1 ,2 ,3 ]
You, Zheng [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, Beijing 100084, Peoples R China
[2] Tsinghua Univ, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
[3] Beijing Informat Sci & Technol Univ, Joint Int Res Lab Adv Photon & Elect, Beijing 100192, Peoples R China
基金
中国国家自然科学基金;
关键词
FIXED PATTERN NOISE; SENSOR;
D O I
10.1364/AO.58.004560
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High-accuracy spot target detection based on a complementary metal-oxide semiconductor (CMOS) image sensor, such as astronomy magnitude, medicine, and astronomy photometrics, needs accurate pixel response. Because pixels have different silicon structures and read outputting, each pixel has non-uniformity response with specific illumination. The flat-field correction of a CMOS image sensor is crucial before image processing. In this work, a flat-field model and correction method based on spot scale areas of CMOS image sensor pixel response are proposed. Compared with traditional full-plane calibration, this method aims at spot areas to fit most selected normal pixels' mean response curve with different light intensities and exposure times, which can guarantee spot imaging areas with higher accurate pixel response. Finally, the accuracy of this flat-field correction method is evaluated by the influence on spot target extraction accuracy. The experimental results indicate that using this flat-field correction method can decrease the non-uniform variance from 7.34 (LSB/10 bit) to 1.91 (LSB/10 bit) (improved by 74.1%) and reduce the noise effect on spot extraction accuracy, which improves it from 0.3453 pixel to 0.0116 pixel (1 sigma). The proposed approach solves the problem of non-uniform pixel response and improves imaging SNR for high-accuracy spot target localization. (c) 2019 Optical Society of America
引用
收藏
页码:4560 / 4568
页数:9
相关论文
共 19 条
  • [11] Non-uniformity correction algorithm based on weighted guided filter and temporal high-pass filter
    Qian, Runda
    Zhao, Dong
    Zhou, Huixin
    Yu, Junna
    Wang, Shicheng
    Rong, Shenghui
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2018, 47 (12):
  • [12] Temporal High-Pass Non-uniformity Correction algorithm based on Grayscale Mapping and Hardware Implementation
    Jin, Minglei
    Jin, Weiqi
    Li, Yiyang
    Li, Shuo
    2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING AND PROCESSING TECHNOLOGY, 2015, 9622
  • [13] A Target-Based Non-Uniformity Self-Correction Method for Infrared Push-Broom Hyperspectral Sensors
    Wu, Bing
    Liu, Chengyu
    Xu, Rui
    He, Zhiping
    Liu, Bin
    Chen, Wangli
    Zhang, Qing
    REMOTE SENSING, 2023, 15 (05)
  • [14] A Median-Ratio Scene-Based Non-Uniformity Correction Method for Airborne Infrared Point Target Detection System
    Ding, Shuai
    Wang, Dejiang
    Zhang, Tao
    SENSORS, 2020, 20 (11) : 1 - 18
  • [15] Integrations of both high resolution reconstruction and non-uniformity correction of infrared image sequence based on regularized maximum a posteriori
    Xiu LIU
    Weiqi JIN
    Yan CHEN
    Chongliang LIU
    Bin LIU
    Frontiers of Optoelectronics in China, 2011, 4 (04) : 438 - 443
  • [16] Integrations of both high resolution reconstruction and non-uniformity correction of infrared image sequence based on regularized maximum a posteriori
    Liu X.
    Jin W.
    Chen Y.
    Liu C.
    Liu B.
    Frontiers of Optoelectronics in China, 2011, 4 (4): : 438 - 443
  • [17] Scene-based non-uniformity correction for high-throughput LWIR imaging spectrometer using optical defocus method
    Wang Hai-yang
    Zheng Wei-jian
    Ming Jing-qian
    Jia Xing-rui
    Fu Yan-peng
    Jin Ning
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES VII, 2020, 11559
  • [18] Accuracy improvement in the source-based calibration of radiative heat flux sensors by consideration of the temperature non-uniformity of the high temperature blackbody
    Park, CW
    Lee, DH
    Kim, BH
    Park, SN
    Shin, HD
    METROLOGIA, 2006, 43 (01) : 135 - 141
  • [19] High-precision GAFCHROMIC EBT film-based absolute clinical dosimetry using a standard flatbed scanner without the use of a scanner non-uniformity correction
    Chung, Heeteak
    Lynch, Bart
    Samant, Sanjiv
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 101 - 115