An attempt by solid-phase microextraction with on-column silylation for a rapid and highly sensitive determination of bisphenol A

被引:0
|
作者
Takao, Y
Lee, HC
Arizono, K
机构
[1] Nagasaki Univ, Fac Environm Studies, Nagasaki 8528521, Japan
[2] Prefectural Univ Kumamoto, Fac Environm & Symbiot Sci, Kumamoto 8628502, Japan
关键词
SPME; bisphenol A; on-column silylation; endocrine disruptors;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combination solid-phase microextraction (SPME) and on-column silylation was applied for a rapid and highly sensitive determination of environmental endocrine disrupters in water samples. In this study, bisphenol A {BPA, 2,2-bis (4-hydroxyphenyl) propane } was selected. BPA was extracted by absorption over the surface of SPME cider which was directly exposed to the sample. The fiber was introduced into the injection port of GC/MS, where BPA. was thermally desorbed followed by injecting bis(trimethylsilyl)trifluoroacetamide (BSTFA) as a derivative with a syringe in the gas phase under He flow. In a comparison without silylation, the peak area of on-column silylated BPA was increased to approximately 20 times. The detection limit was about I ppb, lower than expected for originating in a epoxy-resin adhesive from a SPME fiber.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 50 条
  • [41] Determination of Organochlorine pesticides by gas chromatography with solid-phase microextraction
    Pérez-Trujillo, JP
    Frías, S
    Sánchez, MJ
    Conde, JE
    Rodríguez-Delgado, MA
    CHROMATOGRAPHIA, 2002, 56 (3-4) : 191 - 197
  • [42] Solid-phase microextraction for the determination of iodinated trihalomethanes in drinking water
    Cancho, B
    Ventura, F
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 1999, 841 (02) : 197 - 206
  • [43] Development of a solid-phase microextraction method with micellar desorption for the determination of chlorophenols in water samples -: Comparison with conventional solid-phase microextraction method
    Mahugo Santana, C.
    Torres Padron, M. E.
    Sosa Ferrera, Z.
    Santana Rodriguez, J. J.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) : 13 - 20
  • [44] SOLID-PHASE MICROEXTRACTION FOR THE DETERMINATION OF INORGANIC IONS: APPLICATIONS AND POSSIBILITIES
    Kaykhaii, Massoud
    Dicinoski, Greg W.
    Haddad, Paul R.
    ANALYTICAL LETTERS, 2010, 43 (10-11) : 1546 - 1555
  • [45] Determination of methylcyclopentadienyl manganese tricarbonyl in beverages by solid-phase microextraction
    Forsyth, DS
    Dusseault, L
    FOOD ADDITIVES AND CONTAMINANTS, 1997, 14 (03): : 301 - 307
  • [46] Determination of organochlorine pesticides by gas chromatography with solid-phase microextraction
    J. P. Pérez-Trujillo
    S. Frías
    M. J. Sáchez
    J. E. Conde
    M. A. Rodríguez-Delgado
    Chromatographia, 2002, 56 : 191 - 197
  • [47] Determination of Pesticides in Water by Solid-Phase Microextraction and Gas Chromatography
    Popp, P.
    Mothes, S.
    Brueggemann, L.
    Vom Wasser, 1995, (85):
  • [48] Determination of aqueous chlorothalonil with solid-phase microextraction and gas chromatography
    Chen, SF
    Su, YS
    Jen, JF
    JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) : 105 - 110
  • [49] DETERMINATION OF FATTY-ACIDS USING SOLID-PHASE MICROEXTRACTION
    PAN, L
    ADAMS, M
    PAWLISZYN, J
    ANALYTICAL CHEMISTRY, 1995, 67 (23) : 4396 - 4403
  • [50] Determination of acetone in seawater using derivatization solid-phase microextraction
    Edward D. Hudson
    Kadek Okuda
    Parisa A. Ariya
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1275 - 1282