An attempt by solid-phase microextraction with on-column silylation for a rapid and highly sensitive determination of bisphenol A

被引:0
|
作者
Takao, Y
Lee, HC
Arizono, K
机构
[1] Nagasaki Univ, Fac Environm Studies, Nagasaki 8528521, Japan
[2] Prefectural Univ Kumamoto, Fac Environm & Symbiot Sci, Kumamoto 8628502, Japan
关键词
SPME; bisphenol A; on-column silylation; endocrine disruptors;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combination solid-phase microextraction (SPME) and on-column silylation was applied for a rapid and highly sensitive determination of environmental endocrine disrupters in water samples. In this study, bisphenol A {BPA, 2,2-bis (4-hydroxyphenyl) propane } was selected. BPA was extracted by absorption over the surface of SPME cider which was directly exposed to the sample. The fiber was introduced into the injection port of GC/MS, where BPA. was thermally desorbed followed by injecting bis(trimethylsilyl)trifluoroacetamide (BSTFA) as a derivative with a syringe in the gas phase under He flow. In a comparison without silylation, the peak area of on-column silylated BPA was increased to approximately 20 times. The detection limit was about I ppb, lower than expected for originating in a epoxy-resin adhesive from a SPME fiber.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 50 条
  • [1] Use of solid-phase microextraction followed by on-column silylation for determining chlorinated bisphenol A in human plasma by gas chromatography-mass spectrometry
    del Olmo, M
    Zafra, A
    Suárez, B
    Gonzalez-Casado, A
    Taoufiki, J
    Vílchez, JL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 167 - 172
  • [2] Rapid determination of organotin compounds by headspace solid-phase microextraction
    Le Gac, M
    Lespes, G
    Potin-Gautier, M
    JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) : 123 - 134
  • [3] Determination of phenols by solid-phase microextraction
    Bartak, P
    Cap, L
    JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 171 - 175
  • [4] A RAPID AND HIGHLY SENSITIVE SOLID-PHASE RADIOASSAY FOR PLASMINOGEN ACTIVATORS
    ROCHE, PC
    CAMPEAU, JD
    SHAW, ST
    THROMBOSIS RESEARCH, 1983, 31 (02) : 269 - 277
  • [5] Advances for sensitive, rapid and selective extraction in different configurations of solid-phase microextraction
    Mehdinia, Ali
    Aziz-Zanjani, Mohammad Ovais
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 51 : 13 - 22
  • [6] A chemometric strategy for optimization of solid-phase microextraction: Determination of bisphenol a and 4-nonylphenol with HPLC
    Liu, Xiaoyan
    Zhang, Xiaoyun
    Zhang, Haixia
    Liu, Mancang
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (07) : 596 - 600
  • [7] Determination of haloethers in water by solid-phase microextraction
    Huang, SD
    Ting, CY
    Lin, CS
    JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) : 239 - 246
  • [8] Determination of polychlorinated biphenyls in human blood by solid-phase extraction including on-column lipid decomposition
    Janák, K
    Jensen, E
    Becher, G
    JOURNAL OF CHROMATOGRAPHY B, 1999, 734 (02): : 219 - 227
  • [9] Use of solid-phase microextraction for the analysis of bisphenol A and bisphenol A diglycidyl ether in food simulants
    Salafranca, J
    Batlle, R
    Nerín, C
    JOURNAL OF CHROMATOGRAPHY A, 1999, 864 (01) : 137 - 144
  • [10] On-fibre silylation following solid-phase microextraction for the determination of acidic herbicides in water samples by gas chromatography
    Rodríguez, I
    Rubí, E
    González, R
    Quintana, JB
    Cela, R
    ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) : 259 - 266