Biomechanical Evaluation and the Assisted 3D Printed Model in the Patient-Specific Preoperative Planning for Thoracic Spinal Tuberculosis: A Finite Element Analysis

被引:6
|
作者
Wang, Bingjin [1 ]
Ke, Wencan [1 ]
Hua, Wenbin [1 ]
Zeng, Xianlin [1 ]
Yang, Cao [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Dept Orthopaed, Wuhan, Peoples R China
基金
国家重点研发计划;
关键词
finite element analysis; 3D printed model; thoracic spinal tuberculosis; preoperative planning; spinal fixation; biomechanics; SCREW INSERTION PROCEDURE; LUMBAR INTERBODY FUSION; SURGICAL-TREATMENT; POSTERIOR; INSTRUMENTATION; DEBRIDEMENT; STABILITY; FIXATION; TEMPLATES; PLACEMENT;
D O I
10.3389/fbioe.2020.00807
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Posterior fixation is superior to anterior fixation in the correction of kyphosis and maintenance of spinal stability for the treatment of thoracic spinal tuberculosis. However, the process of selecting the appropriate spinal fixation method remains controversial, and preoperative biomechanical evaluation has not yet been investigated. In this study, we aimed to analyze the application of the assisted finite element analysis (FEA) and the three-dimensional (3D) printed model for the patient-specific preoperative planning of thoracic spinal tuberculosis. An adult patient with thoracic spinal tuberculosis was included. A finite element model of the T7-T11 thoracic spine segments was reconstructed to analyze the biomechanical effect of four different operative constructs. The von Mises stress values of the implants in the vertical axial load and flexion and extension conditions under a 400-N vertical axial pre-load and a 10-N.m moment were calculated and compared. A 3D printed model was used to describe and elucidate the patient's condition and simulate the optimal surgical design. According to the biomechanical evaluation, the patient-specific preoperative surgical design was prepared for implementation. The anterior column, which was reconstructed with titanium alloy mesh and a bone graft with posterior fixation using seven pedicle screws (M+P) and performed at the T7-T11 level, decreased the von Mises stress placed on the right rod, T7 pedicle screw, and T11 pedicle. Moreover, the M+P evaded the left T9 screw without load bearing. The 3D printed model and preoperative surgical simulation enhanced the understanding of the patient's condition and facilitated patient-specific preoperative planning. Good clinical results, including no complication of implants, negligible loss of the Cobb angle, and good bone fusion, were achieved using the M+P surgical design. In conclusion, M+P was recommended as the optimal method for preoperative planning since it enabled the preservation of the normal vertebra and prevented unnecessary internal fixation. Our study indicated that FEA and the assisted 3D printed model are tools that could be extremely useful and effective in the patient-specific preoperative planning for thoracic spinal tuberculosis, which can facilitate preoperative surgical simulation and biomechanical evaluation, as well as improve the understanding of the patient's condition.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Development of a Patient-Specific 3D-Printed Liver Model for Preoperative Planning
    Madurska, Marta J.
    Poyade, Matthieu
    Eason, David
    Rea, Paul
    Watson, Angus J. M.
    SURGICAL INNOVATION, 2017, 24 (02) : 145 - 150
  • [2] Functional Evaluation of a Patient-specific 3D Printed Model of Aortic Regurgitation
    Vukicevic, Marija
    Maragiannis, Dimitrios
    Jackson, Matthew
    Little, Stephen H.
    CIRCULATION, 2015, 132
  • [3] Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis
    Sutradhar, Alok
    Park, Jaejong
    Carrau, Diana
    Miller, Michael J.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 52 : 8 - 17
  • [4] Patient-Specific Finite Element Analysis of Ascending Thoracic Aortic Aneurysm
    Wisneski, Andrew D.
    Mookhoek, Aart
    Chitsaz, Sam
    Hope, Michael D.
    Guccione, Julius M.
    Ge, Liang
    Tseng, Elaine E.
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (06): : 765 - 772
  • [5] Biomechanical Analysis of Adjacent Segments after Spinal Fusion Surgery Using a Geometrically Parametric Patient-Specific Finite Element Model
    Wang, Yuming
    Shen, Qianyi
    Liang, Chang
    Shen, Yanzhu
    Tang, Xiangsheng
    Yi, Ping
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (203):
  • [6] Patient-specific Finite Element Model of a Spinal Tumor for Thermal Ablation
    Ding, Jinli
    Nan, Qun
    Liu, Youjun
    APPLIED MECHANICS AND MECHANICAL ENGINEERING II, PTS 1 AND 2, 2012, 138-139 : 937 - 940
  • [7] Patient-specific 3D printed model of biliary ducts with congenital cyst
    Allan, Amee
    Kealley, Catherine
    Squelch, Andrew
    Wong, Yin How
    Yeong, Chai Hong
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (01) : 86 - 93
  • [8] Intraoperative brain shift prediction using a 3D inhomogeneous patient-specific finite element model
    Hu, Jingwen
    Jin, Xin
    Lee, Jong B.
    Zhang, Lizing
    Chaudhary, Vipin
    Guthikonda, Muram
    Yang, King H.
    King, Albert I.
    JOURNAL OF NEUROSURGERY, 2007, 106 (01) : 164 - 169
  • [9] 3D Patient-Specific Finite Element Model (FEM) of Intracorneal Ring Segment (ICRS) Implantation
    Seven, Ibrahim
    Grytz, Rafael
    Dupps, William J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [10] Patient-Specific 3D Finite-Element Analysis of Miniscrew Implants during Orthodontic Treatment
    Ammar, Hussein H.
    Mucino, Victor H.
    Ngan, Peter
    Crout, Richard J.
    Mukdadi, Osama M.
    IMECE2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 2, 2010, : 109 - 112