Low voltage and variable-pressure scanning electron microscopy of fractured composites

被引:8
|
作者
de Oliveira Hein, Luis Rogerio [1 ]
de Campos, Kamila Amato [1 ]
Reis de Oliveira Caltabiano, Pietro Carelli [1 ]
机构
[1] UNESP Univ Estadual Paulista, DMT Dept Mat & Technol, LAIMat Mat Image Anal Lab, BR-12516410 Guaratingueta, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Monte Carlo; Low voltage; Variable pressure scanning electron microscope; Signal-to-noise ratio; X-RAY-MICROANALYSIS; AMPLIFICATION; QUALITY; MODEL;
D O I
10.1016/j.micron.2012.04.012
中图分类号
TH742 [显微镜];
学科分类号
摘要
Uncoated fracture surfaces of carbon-epoxy composites are investigated using a variable-pressure environmental scanning electron microscope (VP-ESEM), under optimized conditions for topographic description, image quality and sample preservation. Always using freeware or open source programs, parameters for low-voltage and low vacuum are stipulated with the support of Monte Carlo simulations combined to topographic measurements, tailoring the VP-ESEM setup for visualization of fine relief details. Based on topographic information from atomic force microscope (AFM) images, finest fracture steps were measured. These were the references to optimize and define boundaries for applied beam voltages and chamber pressures, restricted by the beam penetration depth and gas-electron interactions, guided by Monte Carlo simulations and signal-to-noise measurements. For VP mode, ideal chamber pressure was found around 30-40 Pa at 3 keV beam voltage and 6 mm working distance. Lower pressures will cause noise due to electron charging and gas excess provokes resolution degradation and noise due to positive charging and electron beam scattering, raising the skirt radius. When a larger working distance is necessary, it can be compensated by adjusting the detector bias and the probe current, or even lowering chamber pressure, but the signal-to-noise ratio will certainly change. Monte Carlo simulations provided a good approach to optimize imaging conditions under low vacuum and low voltage for fractographic analysis of carbon-epoxy composites. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1039 / 1049
页数:11
相关论文
共 50 条
  • [1] New system for secondary electron detection in variable-pressure scanning electron microscopy
    Slowko, W.
    JOURNAL OF MICROSCOPY-OXFORD, 2006, 224 : 97 - 99
  • [2] Swelling and delamination of multi-electrode sensor arrays studied by variable-pressure scanning electron microscopy
    Lemoine, P
    Mailley, P
    Hyland, M
    McLaughlin, JM
    McAdams, E
    Anderson, J
    Lynch, A
    Diamond, D
    Leader, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 50 (03): : 313 - 321
  • [3] Scanning electron microscopy of food-poisoning bacterium Bacillus cereus using a variable-pressure SEM
    Nishimura, M
    Wada, M
    Akiba, T
    Yamada, M
    JOURNAL OF ELECTRON MICROSCOPY, 2003, 52 (02): : 153 - 159
  • [4] Image quality improvement using helium gas in low voltage variable pressure scanning electron microscopy
    Oho, E
    Asai, N
    Itoh, S
    JOURNAL OF ELECTRON MICROSCOPY, 2000, 49 (06) : 761 - 763
  • [5] Low voltage scanning electron microscopy
    Joy, DC
    Joy, CS
    MICRON, 1996, 27 (3-4) : 247 - 263
  • [6] Low-voltage backscattered electron imaging of non-coated biological samples in a low-vacuum environment using a variable-pressure scanning electron microscope with a YAG-detector
    Ushiki, Tatsuo
    Hashizume, Hiroya
    Itoh1, Sukehiro
    Kuboki1, Kenzo
    Saito, Syobu
    Tanaka, Keiichi
    Microscopy, 1998, 47 (04): : 351 - 354
  • [7] Low-voltage backscattered electron imaging of non-coated biological samples in a low-vacuum environment using a variable-pressure scanning electron microscope with a YAG-detector
    Ushiki, T
    Hashizume, H
    Itoh, S
    Kuboki, K
    Saito, S
    Tanaka, K
    JOURNAL OF ELECTRON MICROSCOPY, 1998, 47 (04): : 351 - 354
  • [8] Biomaterials with low-voltage scanning electron microscopy
    LajousPetter, AM
    Schnoy, N
    Holland, G
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 73 - 73
  • [9] On low voltage scanning electron microscopy and chemical microanalysis
    Boyes, ED
    MICROSCOPY AND MICROANALYSIS, 2000, 6 (04) : 307 - 316
  • [10] LOW-VOLTAGE SCANNING ELECTRON-MICROSCOPY
    PAWLEY, J
    JOURNAL OF MICROSCOPY, 1984, 136 (OCT) : 45 - 68