Behaviour of fibre reinforced beam-column sub-assemblages under reversed cyclic loading

被引:28
|
作者
Roehm, Constanze [1 ]
Novak, Balthasar
Sasmal, Saptarshi [2 ]
Karusala, Ramanjaneyulu [2 ]
Srinivas, Voggu [2 ]
机构
[1] Univ Stuttgart, Inst Lightweight Struct & Conceptual Design, ILEK, D-70569 Stuttgart, Germany
[2] CSIR Struct Engn Res Ctr, Madras 600113, Tamil Nadu, India
关键词
Beam-column joint; Steel fibre reinforced concrete; Cyclic loading; Experimental study; Joint shear strength; CONCRETE; PERFORMANCE; JOINTS;
D O I
10.1016/j.conbuildmat.2012.04.114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The potential of usage of steel fibre reinforced concrete (FRC) in structural components like beam-column joints under cyclic loading has been explored in the present study. Three different types of beam-column sub-assemblages, i.e. (i) with normal concrete, and designed according to Indian Standard and Eurocode including seismic joint detailing (Type A). (ii) adopting modified reinforcement detailing but including FRC and, (iii) designed for target joint failure (Type B) as well as flexural failure (Type C), have been considered. The specimens were experimentally investigated under repetitive reversed cyclic loading. Performance of the specimens under cyclic loading is evaluated in terms of failure mode, energy dissipation, strength degradation, shear deformation, strain development in reinforcement, etc. It has been found that longitudinal reinforcements of FRC specimen were found to be yielded at the face of the column and joint failure was completely avoided. At a drift level of +/- 5%, both the code based ductile specimens (Type A) showed a strength deterioration of 30% after the third cycle whereas Type B and Type C specimens experienced 10% and 20%, respectively. The present study has also brought out that all specimens of Type B performed better than Eurocode based reference ductile (Type A) in terms of energy dissipation. It is also observed that flexural specimens (Type C) were able to dissipate higher seismic energy than that obtained from Indian Standard based full ductile specimen (Type A). The results and observations of the present study would help in understanding the behaviour of critical regions of structures such as beam-column sub-assemblages and the efficacy of usage of FRC in those joints under cyclic loading. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:319 / 329
页数:11
相关论文
共 50 条
  • [31] Progressive collapse resistance of precast beam-column sub-assemblages with engineered cementitious composites
    Kang, Shao-Bo
    Tan, Kang Hai
    Yang, En-Hua
    ENGINEERING STRUCTURES, 2015, 98 : 186 - 200
  • [32] Modeling of Precast Reinforced Concrete Beam-column Joints Under Cyclic Loading
    Tarabia, Ahmed M.
    Etman, Emad E.
    Allam, Said M.
    Aboelhassan, Mohamed G.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (14) : 7626 - 7655
  • [33] Reinforced concrete beam-column joints with lap splices under cyclic loading
    Karabinis, AI
    STRUCTURAL ENGINEERING AND MECHANICS, 2002, 14 (06) : 649 - 660
  • [34] Benchmark Numerical Model for Progressive Collapse Analysis of RC Beam-Column Sub-Assemblages
    El-Ariss, Bilal
    Elkholy, Said
    Shehada, Ahmed
    BUILDINGS, 2022, 12 (02)
  • [35] BEHAVIOR OF PARTIALLY PRESTRESSED BEAM-COLUMN JOINTS UNDER REVERSED CYCLIC LOADING.
    Tang, Jiuru
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1987, 8 (05): : 1 - 15
  • [36] Performance of Stalite lightweight SCC beam-column joints under reversed cyclic loading
    Omar, Ahmed T.
    AbdelAleem, Basem H.
    Hassan, Assem A. A.
    ENGINEERING STRUCTURES, 2023, 288
  • [37] Structural behaviour of 2D post-tensioned precast beam-column sub-assemblages subjected to column loss scenario
    Tran, Manh Ha
    Tan, Kang Hai
    ENGINEERING STRUCTURES, 2023, 289
  • [38] Experimental investigation on dynamic response behavior of PC beam-column sub-assemblages under middle-joint drop-weight loading
    Li, Zhong-Xian
    Liu, Haokun
    Shi, Yanchao
    Ding, Yang
    Zhang, Huishen
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [39] Evaluation of performance of non-invasive upgrade strategy for beam-column sub-assemblages of poorly designed structures under seismic type loading
    Sasmal, Saptarshi
    Nath, Dikshita
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (11): : 1817 - 1835
  • [40] Steel fibre reinforced high performance concrete beam-column joints subjected to cyclic loading
    Department of Civil Engineering, National Institute of Technology, Calicut-673601, India
    ISET J. Earthqu. Technol., 2007, 3-4