Thermal conductivity measurements on xonotlite-type calcium silicate by the transient hot-strip method

被引:12
|
作者
Wei, Gaosheng [1 ]
Zhang, Xinxin [2 ]
Yu, Fan [2 ]
机构
[1] N China Elect Power Univ, China Condit Monitoring & Control Power Plant Equ, Sch Energy & Power Engn, Key Lab,Minist Educ, Beijing 102206, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Mech Engn, Beijing 100083, Peoples R China
来源
JOURNAL OF UNIVERSITY OF SCIENCE AND TECHNOLOGY BEIJING | 2008年 / 15卷 / 06期
基金
中国国家自然科学基金;
关键词
thermal conductivity; hot-strip method; xonotlite-type calcium silicate; insulation;
D O I
10.1016/S1005-8850(08)60289-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The experimental results of the thermal conductivities of xonotlite-type calcium silicate insulation materials were presented at different temperatures and pressures. Two appropriative surroundings, i.e. an elevated temperature surrounding from ambient temperature to 1450 K and a vacuum surrounding from atmosphere pressure to 10(-3) Pa, were designed for the transient hot-strip (THS) method. The thermal conductivities of xonotlite-type calcium silicate with four densities from ambient temperature to 1000 K and 0.045 Pa to atmospheric pressure were measured. The results show that the thermal conductivity of xonotlite-type calcium silicate decreases apparently with the fall of density, and decreases apparently with the drop of pressure, and reaches the least value at about 100 Pa. The thermal conductivity of xonotlite-type calcium silicate increases almost linearly with T-3, and increases more abundantly with low density than with high density. The thermal conductivity measurement uncertainty is estimated to be approximately 3% at ambient temperature, and 6% at 800 K. (C) 2008 University of Science and Technology Beijing. All rights reserved.
引用
收藏
页码:791 / 795
页数:5
相关论文
共 50 条
  • [21] THEORETICAL STUDY ON TRANSIENT HOT-STRIP METHOD BY NUMERICAL ANALYSIS
    Wei, Gaosheng
    Du, Xiaoze
    Zhang, Xinxin
    Yu, Fan
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 1, 2009, : 481 - 489
  • [22] Measurements of the Thermal Effusivity of a Drop-Size Liquid Using the Pulse Transient Hot-Strip Technique
    M. Gustavsson
    H. Nagai
    T. Okutani
    International Journal of Thermophysics, 2005, 26 : 1803 - 1813
  • [23] Measuring thermal conductivity of thin films and coatings with the ultra-fast transient hot-strip technique
    Belkerk, B. E.
    Soussou, M. A.
    Carette, M.
    Djouadi, M. A.
    Scudeller, Y.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (29)
  • [24] A NEW METHOD FOR THE EVALUATION OF THERMAL-CONDUCTIVITY AND THERMAL-DIFFUSIVITY FROM TRANSIENT HOT STRIP MEASUREMENTS
    SABUGA, W
    HAMMERSCHMIDT, U
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1995, 16 (02) : 557 - 565
  • [25] Measurements of the thermal effusivity of a drop-size liquid using the pulse transient hot-strip technique
    Gustavsson, M
    Nagai, H
    Okutani, T
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2005, 26 (06) : 1803 - 1813
  • [26] Determination of Thermal Diffusivity/conductivity of Oxide Scale Formed on Steel Plate by Laser Flash Method through Thermal Effusivity Measurement by Transient Hot-strip Method
    Endo, Rie
    Hayashi, Hiroki
    Li, Mu
    Akoshima, Megumi
    Okada, Hikaru
    Tanei, Hiroshi
    Hayashi, Miyuki
    Susa, Masahiro
    ISIJ INTERNATIONAL, 2020, 60 (12) : 2773 - 2779
  • [27] TEMPERATURE-DEPENDENCE OF THERMAL-CONDUCTIVITIES AND THERMAL DIFFUSIVITIES OF COMPOSITES USING TRANSIENT HOT-STRIP METHOD
    SAXENA, NS
    GUSTAFSSON, SE
    CHOHAN, MA
    MAQSOOD, A
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1989, 13 (04) : 411 - 417
  • [28] A new quadrupole model of the transient hot strip method for thermal conductivity measurement
    Ding, T.
    Jannot, Y.
    Degiovanni, A.
    Weber, M.
    Ouhajjou, J.
    HIGH TEMPERATURES-HIGH PRESSURES, 2015, 44 (03) : 187 - 209
  • [29] INTERSTITIAL AIR-PRESSURE DEPENDENCE OF EFFECTIVE THERMAL-CONDUCTIVITY AND DIFFUSIVITY OF RAJASTHAN DESERT SAND USING TRANSIENT HOT-STRIP METHOD
    SAXENA, NS
    CHOHAN, MA
    GUSTAFSSON, SE
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (01): : 51 - 54
  • [30] Thermal conductivity measurements of liquids with transient hot-bridge method
    Albouchi F.
    Mzali F.
    Saadaoui S.
    Jemni A.
    Instrumentation Mesure Metrologie, 2019, 18 (01): : 25 - 30