The Role of Portable Air Purifiers and Effective Ventilation in Improving Indoor Air Quality in University Classrooms

被引:18
|
作者
Aldekheel, Mohammad [1 ,2 ]
Altuwayjiri, Abdulmalik [3 ]
Tohidi, Ramin [1 ]
Farahani, Vahid Jalali [1 ]
Sioutas, Constantinos [1 ]
机构
[1] Univ Southern Calif, Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
[2] Kuwait Univ, Dept Civil Engn, POB 5969, Kuwait 13060, Kuwait
[3] Majmaah Univ, Coll Engn, Dept Civil & Environm Engn, Al Majmaah 11952, Saudi Arabia
关键词
air pollution; indoor air quality; particulate matter (PM); ventilation; ultrafine particles; portable air purifier; ULTRAFINE PARTICLES; CARBON-DIOXIDE; EXCHANGE-RATES; HEALTH; ENVIRONMENTS; CLEANER; PENETRATION; PERFORMANCE; FILTRATION; POLLUTION;
D O I
10.3390/ijerph192114558
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study we investigated the effectiveness of air purifiers and in-line filters in ventilation systems working simultaneously inside various classrooms at the University of Southern California (USC) main campus. We conducted real-time measurements of particle mass (PM), particle number (PN), and carbon dioxide (CO2) concentrations in nine classrooms from September 2021 to January 2022. The measurement campaign was carried out with different configurations of the purifier (i.e., different flow rates) while the ventilation system was continuously working. Our results showed that the ventilation systems in the classrooms were adequate in providing sufficient outdoor air to dilute indoor CO2 concentrations due to the high air exchange rates (2.63-8.63 h(-1)). The particle penetration coefficients (P) of the investigated classrooms were very low for PM (<0.2) and PN (<0.1), with the exception of one classroom, corroborating the effectiveness of in-line filters in the ventilation systems. Additionally, the results showed that the efficiency of the air purifier exceeded 95% in capturing ultrafine and coarse particles and ranged between 82-88% for particles in the accumulation range (0.3-2 mu m). The findings of this study underline the effectiveness of air purifiers and ventilation systems equipped with efficient in-line filters in substantially reducing indoor air pollution.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Synergistic Impact on Indoor Air Quality: The Combined Use of Air Conditioners, Air Purifiers, and Fresh Air Systems
    Jia, Lizhi
    Ge, Jufeng
    Wang, Zhiqiang
    Jin, Wufeng
    Wang, Congcong
    Dong, Zhanwei
    Wang, Cheng
    Wang, Ren
    BUILDINGS, 2024, 14 (06)
  • [32] Factors affecting real-world applications of HEPA purifiers in improving indoor air quality
    Lowther, Scott D.
    Deng, Wei
    Fang, Zheng
    Booker, Douglas
    Whyatt, J. Duncan
    Wild, Oliver
    Wang, Xinming
    Jones, Kevin C.
    ENVIRONMENTAL SCIENCE-ADVANCES, 2023, 2 (02): : 235 - 246
  • [33] Improving indoor air quality
    1600, Alexandria University (42):
  • [34] Rating of mobile indoor air purifiers
    Finger, H.
    Schneiderwind, U.
    Asbach, C.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2015, 75 (11-12): : 497 - 502
  • [35] Indoor air quality investigations at five classrooms
    Lee, SC
    Chang, M
    INDOOR AIR, 1999, 9 (02) : 134 - 138
  • [36] Improving Indoor Air Quality with Natural Ventilation Methods: A Simulation Study
    Yetis, Caner
    Kayili, Merve Tuna
    ICONARP INTERNATIONAL JOURNAL OF ARCHITECTURE AND PLANNING, 2024, 12 (01): : 1 - 23
  • [37] IMPROVING INDOOR AIR QUALITY USING LOCAL EXHAUST VENTILATION (LEV)
    Hussin, Norasikin Binti
    Ibrahim, Dzullijah Binti
    Ahmad, Farrah Noor Binti
    Yahya, Nur Hayati Binti Mohd
    Hashim, Siti Mardini Binti
    JURNAL TEKNOLOGI, 2015, 76 (06): : 7 - 11
  • [38] Ventilation for acceptable indoor air quality
    ASHRAE Standard, 2007, (62.1-2007): : 1 - 41
  • [39] Effect of ventilation on indoor air quality
    Chen Jin-hua
    Duan Sheng-hui
    Zheng Ping
    Zhao Wen-jiang
    Zi Li-mei
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 48 - 52
  • [40] INDOOR AIR-QUALITY AND VENTILATION
    BERGLUND, MB
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (02): : 47 - 47