A New Algorithm for Spectral Drift Calculation in a Gamma-ray Spectrometer

被引:2
|
作者
Qin Zhangjian [1 ]
Ge Liangquan [1 ]
Wu Qifan [2 ]
Cheng Jianping [2 ]
机构
[1] Chengdu Univ Technol, Sch Nucl Technol & Automat Engn, Chengdu 610059, Peoples R China
[2] Tsinghua Univ, Dept Phys Elect, Beijing 100084, Peoples R China
关键词
Spectral drift; Spectra stabilization; Gamma-ray spectrometer; Least squares method; STABILIZATION; DETECTORS;
D O I
10.4028/www.scientific.net/AMR.346.705
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Spectral drift of any origin consisting of detectors and nuclear electronics affects the long-term stability in a gamma-ray spectrometer, which is essential to maintaining the high quality of gamma energy spectra. The feedback regulation according to the quantity of spectral drift can restore the system's stability. A new algorithm for spectral drift calculation is given in this paper. A digital logic unit is developed in a FPGA chip based on the algorithm, and a MCU coordinating with it can fast calculate the spectral drift within only less than 110 instruction periods.
引用
收藏
页码:705 / +
页数:2
相关论文
共 50 条
  • [41] GE(LI) SPECTROMETER FOR GAMMA-RAY ASTRONOMY
    HICKS, DB
    JACOBSON, AS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 169 - 177
  • [42] A PRECISION CURVED CRYSTAL GAMMA-RAY SPECTROMETER
    RYDE, N
    ANDERSSON, B
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1955, 68 (12): : 1117 - &
  • [43] STUDIES ON THE LINEARITY OF A SCINTILLATION GAMMA-RAY SPECTROMETER
    ERIKSEN, VO
    JENSSEN, G
    PHYSICAL REVIEW, 1952, 85 (01): : 150 - 150
  • [44] GAMMA-RAY MEASUREMENTS WITH A MAGNETIC LENS SPECTROMETER
    HORNYAK, WF
    LAURITSEN, T
    RASMUSSEN, VK
    PHYSICAL REVIEW, 1949, 76 (06): : 731 - 739
  • [45] CERENKOV SPECTROMETER FOR MEASURING GAMMA-RAY ENERGIES
    HACHATURJAN, MN
    PANTUJEV, VS
    NUCLEAR INSTRUMENTS & METHODS, 1963, 25 (01): : 173 - 176
  • [46] A COAXIAL GE(LI) GAMMA-RAY SPECTROMETER
    SAKAI, E
    SUZUKI, T
    GOTOH, H
    SEKIGUCH.N
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1966, 3 (12): : 534 - &
  • [47] AN ULTRALOW BACKGROUND GERMANIUM GAMMA-RAY SPECTROMETER
    BRODZINSKI, RL
    BROWN, DP
    EVANS, JC
    HENSLEY, WK
    REEVES, JH
    WOGMAN, NA
    AVIGNONE, FT
    MILEY, HS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 239 (02): : 207 - 213
  • [48] COMPUTER SIMULATION OF AN AIRBORNE GAMMA-RAY SPECTROMETER
    CLARK, RB
    ADAMS, JAS
    DUVAL, JS
    JOURNAL OF GEOPHYSICAL RESEARCH, 1972, 77 (17): : 3021 - +
  • [49] Simulation of CdZnTe gamma-ray spectrometer response
    Glière, A
    Rosaz, M
    Verger, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 250 - 254
  • [50] BOREHOLE GAMMA-RAY SPECTROMETER FOR URANIUM EXPLORATION
    GEORGE, DC
    EVANS, HB
    GEOPHYSICS, 1979, 44 (03) : 413 - 413