A New Algorithm for Spectral Drift Calculation in a Gamma-ray Spectrometer

被引:2
|
作者
Qin Zhangjian [1 ]
Ge Liangquan [1 ]
Wu Qifan [2 ]
Cheng Jianping [2 ]
机构
[1] Chengdu Univ Technol, Sch Nucl Technol & Automat Engn, Chengdu 610059, Peoples R China
[2] Tsinghua Univ, Dept Phys Elect, Beijing 100084, Peoples R China
关键词
Spectral drift; Spectra stabilization; Gamma-ray spectrometer; Least squares method; STABILIZATION; DETECTORS;
D O I
10.4028/www.scientific.net/AMR.346.705
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Spectral drift of any origin consisting of detectors and nuclear electronics affects the long-term stability in a gamma-ray spectrometer, which is essential to maintaining the high quality of gamma energy spectra. The feedback regulation according to the quantity of spectral drift can restore the system's stability. A new algorithm for spectral drift calculation is given in this paper. A digital logic unit is developed in a FPGA chip based on the algorithm, and a MCU coordinating with it can fast calculate the spectral drift within only less than 110 instruction periods.
引用
收藏
页码:705 / +
页数:2
相关论文
共 50 条
  • [1] NEW NAI GAMMA-RAY SPECTROMETER
    HASINOFF, MD
    LIM, ST
    MEASDAY, DF
    MULLIGAN, TJ
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (02): : 375 - 379
  • [2] A HIGH RESOLUTION LITHIUM-DRIFT GERMANIUM GAMMA-RAY SPECTROMETER
    TAVENDALE, AJ
    EWAN, GT
    NUCLEAR INSTRUMENTS & METHODS, 1963, 25 (01): : 185 - 187
  • [3] Gamma-ray observations with the Transient Gamma-Ray Spectrometer (TGRS)
    Seifert, H
    Teegarden, BJ
    Cline, TL
    Gehrels, N
    Hurley, KH
    Madden, N
    Owens, A
    Palmer, DM
    Pehl, R
    Ramaty, R
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1996, 120 (04): : C653 - C656
  • [4] GAMMA-RAY LINE INVESTIGATIONS WITH THE DURHAM GAMMA-RAY SPECTROMETER
    AYRE, CA
    BHAT, PN
    OWENS, A
    SUMMERS, WM
    THOMPSON, MG
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1981, 301 (1462): : 687 - 691
  • [5] SILICON GAMMA-RAY SPECTROMETER
    GIBBONS, PE
    NORTHROP, DC
    NATURE, 1960, 188 (4753) : 803 - 803
  • [6] RANGER GAMMA-RAY SPECTROMETER
    METZGER, AE
    ANDERSON, EC
    VANDILLA, MA
    ARNOLD, JR
    NUCLEONICS, 1962, 20 (10): : 64 - +
  • [7] THE TRANSIENT GAMMA-RAY SPECTROMETER
    OWENS, A
    BAKER, R
    CLINE, TL
    GEHRELS, N
    JERMAKIAN, J
    NOLAN, T
    RAMATY, R
    SMITH, G
    STILWELL, DE
    TEEGARDEN, BJ
    TROMBKA, J
    YAVER, H
    CORK, CP
    LANDIS, DA
    LUKE, PN
    MADDEN, NW
    MALONE, D
    PEHL, RH
    HURLEY, K
    MATHIAS, S
    POST, AH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 559 - 567
  • [8] STABILISATION OF A GAMMA-RAY SPECTROMETER
    DIXON, I
    NUCLEAR INSTRUMENTS & METHODS, 1963, 25 (01): : 26 - 28
  • [9] THE GRAD GAMMA-RAY SPECTROMETER
    RESTER, AC
    PIERCEY, RB
    EICHHORN, G
    COLDWELL, RL
    MCKISSON, J
    ELY, DW
    MANN, HM
    JENKINS, DA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 732 - 734
  • [10] THE GAMMA-RAY SCINTILLATION SPECTROMETER
    PEIRSON, DH
    IREDALE, P
    BRITISH JOURNAL OF APPLIED PHYSICS, 1957, 8 (10): : 422 - 422