Optimizing Image Quantification for 177Lu SPECT/CT Based on a 3D Printed 2-Compartment Kidney Phantom

被引:40
|
作者
Tran-Gia, Johannes [1 ]
Lassmann, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
关键词
radionuclide therapy; 2-compartment kidney phantom; 3D printing; partial volume correction; quantitative SPECT/CT; xSPECT Quant; PARTIAL-VOLUME CORRECTION; EMISSION TOMOGRAPHY; QUANTITATIVE SPECT; PET; DOSIMETRY; COMPENSATION; GUIDELINES; RESOLUTION; AGE;
D O I
10.2967/jnumed.117.200170
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work was to find an optimal setup for activity determination of Lu-177-based SPECT/CT imaging reconstructed with 2 commercially available methods (xSPECT Quant and Flash3D). For this purpose, 3-dimensional (3D)-printed phantoms of different geometries were manufactured, different partial-volume correction (PVC) methods were applied, and the accuracy of the activity determination was evaluated. Methods: A 2-compartment kidney phantom (70% cortical and 30% medullary compartment), a sphere, and an ellipsoid of equal volumes were 3D printed, filled with Lu-177, and scanned with a SPECT/CT system. Reconstructions were performed with xSPECT and Flash3D. Different PVC methods were applied to find an optimal quantification setup: method 1 was a geometry-specific recovery coefficient based on the 3D printing model, method 2 was a geometry-specific recovery coefficient based on the low-dose CT scan, method 3 was an enlarged volume of interest including spilled-out counts, method 4 was activity concentration in the peak milliliter applied to the entire CT-based volume, and method 5 was a fixed threshold of 42% of the maximum in a large volume containing the object of interest. Additionally, the influence of postreconstruction gaussian filtering was investigated. Results: Although the recovery coefficients of sphere and ellipsoid differed by only 0.7%, a difference of 31.7% was observed between the sphere and the renal cortex phantoms. Without post-filtering, the model-based recovery coefficients (methods 1 and 2) resulted in the best accuracies (xSPECT, 1.5%; Flash3D, 10.3%), followed by the enlarged volume (method 3) (xSPECT, 8.5%; Flash3D, 13.0%). The peak-milliliter method (method 4) showed large errors only for sphere and ellipsoid (xSPECT, 23.4%; Flash3D, 21.6%). Applying a 42% threshold (method 5) led to the largest quantification errors (xSPECT, 32.3%; Flash3D, 46.7%). After postfiltering, a general increase in the errors was observed. Conclusion: In this work, 3D printing was used as a prototyping technique for a geometry-specific investigation of SPECT/CT reconstruction parameters and PVC methods. The optimal setup for activity determination was found to be an unsmoothed SPECT/CT reconstruction in combination with a recovery coefficient based on the low-dose CT. The difference between spheric and renal recovery coefficients suggests that the typically applied volume-dependent but only sphere-based recovery coefficient lookup tables should be replaced by a more geometry-specific alternative.
引用
收藏
页码:616 / 624
页数:9
相关论文
共 50 条
  • [31] Comparison of 2D planar and 3D SPECT-CT quantification of lung function in patients with lung cancer
    Thillainathan, A. V.
    Gregg, S.
    Elsner, A.
    Avondo, J.
    Bailey, J.
    Reyes, E.
    Underwood, S. R.
    Wechalekar, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S292 - S293
  • [32] COMPARING 2D AND 3D KIDNEY ABSORBED DOSE MEASURES IN PATIENTS RECEIVING 177Lu-DOTATATE THERAPY FOR NEUROENDOCRINE TUMOURS
    Willowson, K. P.
    Ryu, H. J.
    Singh, A.
    Jackson, P.
    Bailey, D. L.
    INTERNAL MEDICINE JOURNAL, 2017, 47 : 8 - 9
  • [33] Whole body planar and 3D quantitative imaging after 177Lu-DOTATATE on CZT SPECT/CT device with MEHRS collimator. First report
    Deshayes, Emmanuel
    Fersing, Cyril
    Hebert, Kevin
    Bardies, Manuel
    Kotzki, Pierre Olivier
    Santoro, Lore
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2021, 24 (02): : 165 - 166
  • [34] Patient-specific 3D Monte-Carlo-based bone marrow dosimetry for Lu-177-PSMA therapy and the potential value of Tc-99m-anti-granulocyte antibody SPECT/CT for image-based 3D active bone marrow localisation
    Gosewisch, A.
    Ilhan, H.
    Tattenberg, S.
    Mairani, A.
    Parodi, K.
    Brosch, J.
    Kaiser, L.
    Gildehaus, F.
    Todica, A.
    Ziegler, S.
    Bartenstein, P.
    Boening, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S169 - S170
  • [35] 177Lu-PSMA-617 Transport in Solid Tumors via a 3D Image-based Spatio-temporal Model
    Piranfar, Anahita
    Soltani, Madjid
    Kashkooli, Farshad Moradi
    Zhan, Wenbo
    Bhandari, Ajay
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [36] A Workflow for Dosimetry of 90Y Radioembolization Based on Quantitative 99mTc-MAA SPECT/CT Imaging and a 3D-Printed Phantom
    Ungania, Sara
    D'Arienzo, Marco
    Mezzenga, Emilio
    Pizzi, Giuseppe
    Vallati, Giulio
    Ianiro, Anna
    Rea, Sandra
    Sciuto, Rosa
    Soriani, Antonella
    Strigari, Lidia
    APPLIED SCIENCES-BASEL, 2022, 12 (20):
  • [37] Quantification of pancreatic uptake in beta cell imaging with 68Gaexendin PET/CT using a 3D-printed anatomical pancreas-kidneys phantom and the NEMA NU2 Image Quality phantom
    Deden, L. N.
    Buitinga, M.
    Meeuwis, A. P. W.
    Ruiter, S.
    Lobeek, D.
    Gotthardt, M.
    Visser, E. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S525 - S526
  • [38] Feasibility of Image Guided Sentinel Node Biopsy using Augmented Reality and SPECT/CT-based 3D avigation
    Brouwer, O. R.
    Van den Berg, N.
    Matheron, H.
    Nieweg, O. E.
    Horenblas, S.
    Van der Poel, H.
    Wendler, T.
    Olmos, R. Valdes
    Van Leeuwen, F.
    ANNALS OF SURGICAL ONCOLOGY, 2013, 20 : S103 - S103
  • [39] Quantification and geometric analysis of coiling patterns in gastropod shells based on 3D and 2D image data
    Noshita, Koji
    JOURNAL OF THEORETICAL BIOLOGY, 2014, 363 : 93 - 104
  • [40] Estimation of [177Lu]PSMA-617 tumor uptake based on voxel-wise 3D Monte Carlo tumor dosimetry in patients with metastasized castration resistant prostate cancer
    Goetz, Theresa Ida
    Lang, Elmar Wolfgang
    Prante, Olaf
    Cordes, Michael
    Kuwert, Torsten
    Ritt, Philipp
    Ludwig, Bernd
    Schmidkonz, Christian
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2020, 59 (05): : 365 - 374